- NBCS 2026 (SP 7:2026) Part D Sec 1 — National Building Construction Standards — Lighting and natural ventilation
Illuminance and lighting quality by room (Table 6), daylight, natural ventilation
- NBCS 2026 (SP 7:2026) Part F — National Building Construction Standards — Fire and life safety
Means of egress (Tables 2–4, cl. 4.4.2), staircase / lobby / lift-well pressurisation (cl. 4.4.2.5, Table 5), emergency lighting (cl. 3.5.6), fire-fighting installations by occupancy (Tables 7A–7J), demand, pumps and duration (Tables 7K / 7M), mains (Table 8), hydrant pressure 3.5–7 bar (cl. 5.1.1 f), sprinklers (cl. 5.1.3), gaseous suppression (cl. 5.1.6 / 5.1.9)
- IS 3646 (Part 1):1992 — Code of practice for interior illumination — general requirements and recommendations for working interiors
Illuminance schedule, uniformity, glare, maintenance
- ECBC 2017 (BEE) — Energy Conservation Building Code — superseded by ECSBC 2024; still enforced where a State has not yet notified ECSBC 2024
Envelope U / SHGC and lighting power density (India option)
- EN 12464-1:2021 — Light and lighting — Lighting of work places — Part 1: Indoor work places
Required Ēm, Uo, UGR, Ra by activity; calculation grid (§4.4)
- IS 732:2019 — Code of practice for electrical wiring installations
Voltage-drop limits, cable selection, protection coordination (adopts IEC 60364)
- IEC 60364-5-52:2009 — Low-voltage electrical installations — Selection and erection of wiring systems
Current-carrying capacity, derating (temperature, grouping, installation method), voltage drop ≤ 3–5 %
- BS 7671:2018+A2 — Requirements for Electrical Installations (IET Wiring Regulations)
Radial / ring circuit arrangements, diversity (Appendix 15 / on-site guide)
- NFPA 70 (NEC 2023) — National Electrical Code
Wiring methods, articles 250, 450, 520, 620, 640, 700, 760, 800
- IS 1293 — Plugs and socket-outlets of rated voltage up to 250 V
6 A / 16 A sockets
- IEC 60884-1 — Plugs and socket-outlets for household and similar purposes
Socket outlets
- IS 2189:2026 — Selection, installation and maintenance of automatic fire detection and alarm system — code of practice
Detector spacing and zoning in India
- NFPA 72 (2022) — National Fire Alarm and Signaling Code
Detection for releasing systems: cross-zoning, spacing, pre-discharge alarms, abort
- EN 54 series — Fire detection and fire alarm systems — components
Detectors, panels, sounders, voice alarm certification
- BS 5839-1:2017 — Fire detection and fire alarm systems for buildings — design, installation, commissioning and maintenance (non-domestic)
Detection categories and cabling
- ANSI/TIA-568 series (568.0-E, .1-E, .2-D, .3-E) — Telecommunications cabling standards
Copper / fibre categories and testing
- ISO/IEC 11801-1:2017 — Generic cabling for customer premises
Cabling classes
- IS 694:2010 — PVC insulated cables for working voltages up to 1100 V
FRLS wiring conductors
- IS 9537 Part 1, 2, 3 — Conduits for electrical installations
MS and PVC conduits