calc.designlink.inBeam angle, spot size & lux
Sample project — Tower A · Electrical
Generated 28 Nov 2026 17:16
For a spot / flood light: centre illuminance and spot diameter from the lumens, beam angle…
Project code SAMPLE
Average in the spot
657.6 lx
1. Inputs
| Group | Input | Value | Unit |
|---|
| Light | Calculate | Lux and spot size from lumens + beam angle | |
| Light | Luminaire output | 1200 | lm |
| Light | Beam angle | 24 | ° |
| Light | Share of the lumens inside the beam | 0.7 | |
| Light | Distance to the lit surface | 3 | m |
2. Results
Result
| Item | Value | Unit | Note / basis |
|---|
| Solid angle Ω = 2π(1 − cos θ/2) | 0.1373 | sr | |
| Intensity I = Φ·share / Ω | 6117.87 | cd | |
| Centre lux E = I / d² | 679.76 | lx | |
| Spot diameter 2·d·tan(θ/2) | 1.28 | m | |
| Average lux in the spot | 657.56 | lx | |
3. Checks
| Check | Result | Note |
|---|
| Beam lumen share assumed — check with the maker's data | PASS | |
4. Worked example
Ω = 2π(1 − cos 12°) = 0.1373 sr; I = 1200 × 0.7 / 0.1373 = 6118 cd; E = 6118 / 3² = 680 lx; D = 2 × 3 × tan 12° = 1.28 m
5. Notes
- Uniform-cone approximation; use the photometric file for the final design.
6. Standards and references
- IS 3646 Part 1 — Code of practice for interior illumination: Recommended illuminance and lighting design
Prepared by
Checked by
Approved by
Results are design aids computed by designlink calc (calc.designlink.in) and must be reviewed by a qualified engineer before issue. Ground levels marked "assumed" have no survey level within reach — verify.