SAMPLE Pole transverse load & foundation — this is what your report looks like, generated from demo inputs. Generate yours → 2 free designs every day for every signed-in account · 1 design free on sign-in · ₹99 + GST per design (report + Excel + DXF) · free for DesignLink companies
Report ready — use Print → Save as PDF (A4 landscape).
Design Linkcalc.designlink.in

Pole transverse load & foundation

Sample project — Tower A · Electrical
Generated 28 Nov 2026 17:16
Wind on the conductors, the pole and the luminaire / bracket plus the pull at a line devia…
Project code SAMPLE
Wind pressure
1045.4 N/m²
Moment at ground
6.662 kN·m
Horizontal load
1.255 kN
Planting depth
1.0 m

1. Inputs

GroupInputValueUnit
PoleHeight above ground9m
PoleTop diameter90mm
PoleBottom diameter160mm
PoleForce coefficient of the pole0.8
PolePole working load (applied 0.6 m below top)2.0kN
PoleLuminaire + bracket projected area0.25m²
Conductors / cablesNumber of overhead conductors (0 = underground feed)0
Conductors / cablesConductor diameter9.0mm
Conductors / cablesWind span35m
Conductors / cablesConductor height above ground7.5m
Conductors / cablesConductor tension (each)2.0kN
Conductors / cablesLine deviation angle0°
Wind and soilBasic wind speed44 m/s
Wind and soilTerrain / height factor k21.0
Wind and soilKd · Ka · Kc0.9
Wind and soilSoil friction angle30°
Wind and soilSoil unit weight18kN/m³
Wind and soilFoundation (concrete) width / diameter0.6m
Wind and soilFactor of safety on the soil2.0

2. Results

Forces

ItemValueUnitNote / basis
Design wind speed Vz44.0m/s
Design pressure pd = 0.6·Vz² × K1045.44N/m²
On the pole0.9409kNat 4.08 m
On the luminaire / bracket0.3136kNat 9 m
On the conductors0.0kN0 × wind span
Deviation pull 2T·sin(θ/2)0.0kN
Moment at ground6.66kN·m
Pole capacity WL × (h − 0.6)16.8kN·m

Foundation

ItemValueUnitNote / basis
Kp = (1 + sinφ)/(1 − sinφ)3.0
Load height e = M/H5.31m
Depth for FoS1.0mHu = 0.5·γ·b·D³·Kp/(e + D) ≥ 2 × H
Rule of thumb (1/6 of total length, typical)1.67m
Adopt1.67m

3. Checks

CheckResultNote
Moment 6.66 ≤ pole capacity 16.80 kN·mPASS
Soil capacity at 1 m ≥ 2 × HPASS

4. Worked example

pd = 0.6 × 44.0² × 0.9 = 1045 N/m²; pole: 1045 × 0.8 × 1.125 m² = 941 N
M = 0.941 × 4.08 + 0.314 × 9 + 0.000 × 7.5 = 6.66 kN·m

5. Notes

6. Standards and references

Prepared by
Checked by
Approved by

Results are design aids computed by designlink calc (calc.designlink.in) and must be reviewed by a qualified engineer before issue. Ground levels marked "assumed" have no survey level within reach — verify.