calc.designlink.inStreet lighting — poles & LED payback
Sample project — Tower A · Electrical
Generated 28 Nov 2026 17:16
Number of poles for a road from the spacing and arrangement, energy of the existing lamps …
Project code SAMPLE
Energy saved
43952.0 kWh/yr
1. Inputs
| Group | Input | Value | Unit |
|---|
| Road | Road length | 2000 | m |
| Road | Pole spacing | 30 | m |
| Road | Arrangement | One side | |
| Lamps | Existing lamp incl. control gear | 280 | W |
| Lamps | LED luminaire | 120 | W |
| Lamps | Burning hours | 4100 | h/year |
| Lamps | Energy cost | 7.5 | ₹/kWh |
| Lamps | LED fitting installed cost | 9500 | ₹ each |
| Lamps | Maintenance saving | 400 | ₹/fitting/yr |
| Lamps | LED life | 10 | years |
| Lamps | Discount rate | 8 | % |
| Lamps | Grid emission factor | 0.716 | kg CO₂/kWh |
2. Results
Energy
| Item | Value | Unit | Note / basis |
|---|
| Existing | 76916.0 | kWh/yr | |
| LED | 32964.0 | kWh/yr | |
| Saving | 43952.0 | kWh/yr | 57 % |
| Annual saving incl. maintenance | 356440.0 | ₹ | |
| Investment | 636500.0 | ₹ | |
| CO₂ saved | 31.47 | t/yr | |
3. Checks
| Check | Result | Note |
|---|
| Payback within the LED life | PASS | |
| Check the lux and uniformity of the LED fitting on this spacing (Street lighting tool) | PASS | |
4. Worked example
Poles per row = ⌊2000 / 30⌋ + 1 = 67; fittings 67
Saving = 67 × (280 − 120) W × 4100 h / 1000 × ₹ 7.5 + maintenance = ₹ 356,440/yr; payback = 636,500 / 356,440 = 1.8 yr
5. Notes
- Burning hours ≈ 11–12 h per night (typical); add a dimming schedule for further savings.
6. Standards and references
- IS 1944 (Parts 1–6) — Code of practice for lighting of public thoroughfares: Outdoor / road lighting classes and levels
Prepared by
Checked by
Approved by
Results are design aids computed by designlink calc (calc.designlink.in) and must be reviewed by a qualified engineer before issue. Ground levels marked "assumed" have no survey level within reach — verify.