Wi-Fi heat map & AP design
Sample project — Tower A · Sample project — Tower A · 5 GHz · 4 APs
design band for coverage (2.4 GHz covers further; 5 / 6 GHz carry the capacity)
Environment
Office / hotel
ITU-R P.1238 distance exponent
AP model
Wi-Fi 6 indoor, 2×2 / 4×4 (standard office)
EIRP, gain, design clients per AP
Targets
primary ≥ -65 dBm on ≥ 95 % of the area, SNR ≥ 25 dB
enterprise WLAN design practice (voice / data grade)
Path loss
L = L₀(1 m, f) + 10·n·log₁₀(d) + Σ wall losses (material × band); RSSI = EIRP − L
ITU-R P.1238 / COST-231 multi-wall model
Placement
greedy coverage on a sample grid, then a capacity split where an AP exceeds its design clients, then channel colouring of neighbours
project
Heights
AP 2.8 m · client 1.0 m
project
Walls
default drywall; per room override
material loss table
Floors
evaluated floor by floor (no slab leakage)
ITU-R P.1238 floor penetration
Code
NBCS 2026 (SP 7:2026) Part D Sec 6 — APs ≥ IEEE 802.11ax / be; horizontal ≤ 90 m, extra TR above 930 m²; coverage, capacity and interference planned with this planning tool and confirmed by a site survey and periodic monitoring
cl. 3.2.5, 3.1.3.2, 3.4.1.1, A-6.3
Cable route
TR → AP drop = (|Δx| + |Δy|) × 1.25 + 8.0 m (rise / fall, slack); TR at the floor's 'tr' point, else the centre of the served area; longest 25.3 m
permanent link ≤ 90 m
2. Checks
Check
Result
Primary coverage ≥ 95 % of the served area at ≥ -65 dBm on every floor
PASS
Minimum SNR ≥ 25 dB in every room
CHECK
Every AP within its design client load
PASS
Neighbouring APs on different channels
PASS
Every AP supports IEEE 802.11ax / be or later (NBCS 2026 Part D Sec 6 cl. 3.2.5 (b))
PASS
Horizontal cable TR → AP ≤ 90 m incl. slack, + 10 m cords (NBCS 2026 Part D Sec 6 cl. 3.1.3.2 / 3.4.1.1 (a))
Worked from this project’s own inputs and results — each value can be traced to the schedules above.
Ground — Plant room: weakest point of the weakest room
lowest minimum RSSI in this project (-69.3 dBm); best server AP-GR-04
Given: AP AP-GR-04 Wi-Fi 6 indoor, 2×2 / 4×4 (standard office) at (21.5, 4) m, Tx 23 dBm, gain 4 dBi · Point (25.75, 15.75) m · Band 5 GHz (5500 MHz), Office / hotel n = 3.0
1. EIRP: EIRP = Ptx + Gant = 23 + 4 = 27 dBm
2. Free-space loss at 1 m: L0 = 20·log10(4π·f/c) = 20·log10(4π × 5500·106 / 3·108) = 47.25 dB
3. Distance (3-D): d = √(Δx² + Δy² + Δz²) = √(12.49² + 1.8²) = 12.62 m(AP 2.8 m, client 1.0 m)
6. APs on the floor: coverage pass + capacity split = 1 + 3 = 4 (442 m² served → 110 m²/AP)
7. Cable (project): drops × length = 4 APs × 2 × 45 m = 360 m
Predictive design — a post-installation validation survey (−65 / −67 dBm, SNR, roaming) confirms the coverage; wall losses are typical values and should be adjusted to the actual construction.
7. Codes and standards
Indian code edition: NBCS 2026 (SP 7:2026). NBCS gives no RSSI / SNR values — the coverage targets are industry design practice.
NBCS 2026 clause
PDF page
Governs
Part D Sec 6 cl. 3.2.5 (b)
2476
Access points support at least IEEE 802.11 ax / be; centralised controller; secure access by the owner
Part D Sec 6 cl. 3.2.5 (last para)
2476
Spacing to avoid frequency overlap; materials, configuration, furnishings; site survey and planning tool; periodic monitoring
Part D Sec 6 cl. 3.1.3.2
2471
Horizontal cable ≤ 90 m incl. slack; additional TR above 930 m² served
Part D Sec 6 cl. 3.4.1.1 (a)
2483
Four-pair UTP / ScTP 90 m with 10 m patch cords
Part D Sec 6 Table 1
2473
Category 6A / Class EA cabling
Part D Sec 6 Annex A-6.3
2499
Coverage by user density, interference management (frequency planning, power control), capacity planning
Standard
Title
Used for
NBCS 2026 (SP 7:2026) Part D Sec 6
National Building Construction Standards — Information and communication enabled installations
Propagation data and prediction methods for the planning of indoor radiocommunication systems
Indoor path-loss model (distance exponent, wall losses)
IEEE 802.11ax / be
Wireless LAN
Wi-Fi 6E / 7
ANSI/TIA-568 series (568.0-E, .1-E, .2-D, .3-E)
Telecommunications cabling standards
Copper / fibre categories and testing
ANSI/TIA-569-E
Telecommunications pathways and spaces
Telecom rooms and pathways
ISO/IEC 11801-1:2017
Generic cabling for customer premises
Cabling classes
Prepared by
Checked by
Approved by
Results are design aids computed by designlink calc (calc.designlink.in) and must be reviewed by a qualified engineer before issue. Ground levels marked "assumed" have no survey level within reach — verify.