DesignLink CAD plugin



Contents
- What you need
- Download and install
- Open the palette
- Sign in, credits and plans
- Drive mode and the expert view
- First time in a drawing: Setup
- Selecting rooms — the same in every tool
- Lighting
- Power points
- Wiring & looping
- Fire alarm devices
- Fire alarm loops, zones and schematic
- CCTV, Data / Tel, PA speakers, Wi-Fi
- Sprinklers
- Toilet plumbing
- ELV cabling & racks
- Lightning & earthing
- Gas suppression
- Car-park ventilation
- HVAC ducts & units
- Cable tray & feeders
- HVLS fans
- Change what was placed
- Numbering
- Cable tray control
- Loop optimiser
- Quantities
- DIALux
- CPWD DSR BOQ
- The expert view (all buttons)
- Quick tools
- Place a drawing from your projects
- Sewer and storm-water wizards
- Troubleshooting
- Every command
1What you need
The plugin draws your services into the open AutoCAD or ZWCAD drawing: you pick rooms and points in the drawing, the palette works out the design and draws the result on its own layers.
| Item | Requirement |
|---|---|
| Windows | Windows 10 / 11, 64-bit. Administrator rights to install. |
| AutoCAD | AutoCAD 2023, 2024, 2025, 2026 and 2027, including verticals (MEP, Architecture, Electrical, Map 3D, Civil 3D). AutoCAD LT is not supported — LT cannot load plugins. |
| ZWCAD | ZWCAD 2024, 2025 and 2026. |
| Internet | The palette pages load from calc.designlink.in, so the PC must be online. |
| Account | A DesignLink login (company users) or a calc.designlink.in sign-in. The plugin is free to download and use — every drawing it makes is free. Design reports and Excel files (schedules, BOQ) need a design credit or a plan (section 4). |
| Drawing | A plan with walls on their own layer works best. Model space, any units (mm, cm, m, inch, feet) — Setup tells the plugin which one. |
2Download and install
One installer covers every supported AutoCAD and ZWCAD on the PC.
Download DesignLinkCAD-Setup.exe from calc.designlink.in/cad/download (or use the copy attached to the e-mail).
Close every AutoCAD and ZWCAD window. If one is still open, Setup stops with “AutoCAD / ZWCAD is running and has the DesignLink plugin loaded. Close every AutoCAD and ZWCAD window, then press Retry.” Close it and press Retry.
Double-click the file and accept the Windows administrator prompt. Click Next / Install with the default folder (C:\Program Files\DesignLink\CAD). If the Microsoft Edge WebView2 runtime is missing, Setup installs it (“Installing Microsoft Edge WebView2 runtime…”).
Click Finish. Nothing else to configure — AutoCAD loads the plugin automatically from the next start; ZWCAD is registered for every version found.
%LOCALAPPDATA%\DesignLink\CAD.C:\Program Files\DesignLink\CAD\ZWCAD\DesignLinkCAD.ZWCAD.dll, then type DLAUTOLOAD — from then on it loads by itself. Or simply run Setup again.3Open the palette
There is no ribbon or menu — everything starts from a typed command.
Start AutoCAD / ZWCAD and open your drawing (the palette needs an open drawing).
Type DESIGNLINK and press Enter. The DesignLink calc palette docks on the right. A dark bar on top shows the CAD, a green dot and the drawing name with its units. Below it is the tool menu: Drive mode, Daily work, the step-by-step website tools that read the drawing, the sewer / storm wizards and Place a drawing.

The Drawing checks at the bottom are a quick test that the palette talks to the drawing: Layers lists every layer with its object count, Pick a point and Read a polyline ask you to click in the drawing.

| Type | What happens |
|---|---|
| DESIGNLINK or DLPALETTE | open / show the palette |
| DLD | open Drive mode on its home screen (the fastest way to work) |
| DLHOME | palette back to the tool menu |
| DLWINDOW | open DesignLink in a separate floating window |
| DLHELP | list every quick tool and drive shortcut on the command line |
| DLLOGOUT | sign out of the palette |
| DLABOUT · DLDIAG · DLCHECK | version · diagnostics for support · self-test (section 6) |
4Sign in, credits and plans
The plugin is free: placing, circuiting, piping, tagging and every drawing it puts in your CAD file cost nothing. Only the design reports and the Excel files need a design credit or a plan.
Click Sign in in the top bar of the palette. Type your DesignLink e-mail and password and click Sign in. The first sign-in gives one design free.

A 6-digit code is e-mailed to you (it is valid for 10 minutes). Type it and click Sign in. Accounts with an authenticator app are asked for the authenticator code instead. The palette remembers the sign-in for 30 days.

The first time only, read the short disclaimer, tick the box and click I agree — continue.
| Action in the plugin | Needs |
|---|---|
| Open the palette, select rooms, place lights / sockets / devices, switch boards, DB, circuit & loop, tag & zone, quantities on screen | nothing — free |
| Your own symbols and layer names saved for next time; your project list in Place a drawing | sign-in |
| Details & legend sheets, schematics, piping / loops drawings, Place a drawing, sewer plan & L-sections — drawn in CAD | nothing — free |
| Design reports (calculations, checks, BOQ), Schedules Excel, CPWD DSR BOQ Excel | a design credit or a plan |
5Drive mode and the expert view
Daily work has two faces. Drive mode shows one decision per screen with big buttons and nothing to scroll — this is what the guide uses. The expert view shows every button at once (section 30).
Type DLD (or choose Drive mode in the tool menu). The home screen asks What do you want to place? — 18 design tools on top, then CPWD DSR BOQ, Quick tools, Change & number, Cable tray control, Loop optimiser, Quantities, DIALux and Setup.

Every screen has the same header: the back arrow (left) goes one step back, the title says what to do now, the small line above it shows the step and the tool. When the drawing has more than one floor, an orange floor button shows the current floor — click it to switch. The dashboard icon (right) opens the expert view; the Drive button there comes back.
| Shortcut | Opens | Shortcut | Opens |
|---|---|---|---|
| DLL | Lighting | DLHV | HVAC ducts & units |
| DLP | Power points | DLCP | Car-park ventilation |
| DLF | Fire alarm devices | DLEA | Lightning & earthing |
| DLFL | Fire alarm loops | DLGS | Gas suppression |
| DLS | Sprinklers | DLEL | ELV cabling & racks |
| DLW | Wiring & looping | DLHF | HVLS fans |
| DLT | Cable tray & feeders | DLE / DLN / DLU | Change what was placed / Numbering / Undo |
| DLTO | Toilet plumbing | DLCT / DLLO | Cable tray control / Loop optimiser |
| DLQT | Quick tools | DLQ / DLDX | Quantities / DIALux |
| DLSET | Setup | DLAX | Building direction |
6First time in a drawing: Setup
Two minutes of setup per drawing makes every tool right first time: the drawing units, the floors, your office layer names and your own blocks.
Type DLSET (or Drive home → Setup). Six tiles: Units & scale, Floors, Layer names, Building direction, My blocks and Check this CAD.

Units & scale — the palette reads the drawing units and shows how wide the plan comes out with each unit (“plan 60.0 m wide”). Click the unit that gives the real building size (a door ≈ 0.9 m), then the plot scale (1:50 / 1:100 / 1:200) — text heights of everything drawn follow it.

Floors — one drawing can hold several floors. Add a floor asks the name and level; Area of GF lets you window round that floor’s plan so rooms picked inside it go to that floor automatically; Rename renames the current floor.

Layer names — type your office layer for each DesignLink layer (blank keeps the DesignLink name) and click Save my layer names. Used for everything drawn from now on, in every drawing (sign-in needed to keep them).

My blocks — Pick a block for a symbol: choose a DesignLink symbol, then click your own block in the drawing. From then on every tool places your block (TAG / CKT go into its attributes when it has them). Preview switches the cyan ghost preview on or off.

Building direction — rows of lights, loops and routes follow the building. Pick a wall / grid line (most buildings), From the UCS, Square to the sheet (0°) or Type an angle.

Check this CAD runs DLCHECK: click an empty spot, the plugin tries every drawing operation on a scratch layer, removes the test objects and prints PASS / FAIL lines — send that text to support when something does not work.

7Selecting rooms — the same in every tool
Every tool that works on rooms shows the same picker with the same tiles in the same order.
How do you want to select the room? — pick one way:
Click inside room click inside each room, Enter when done · Rectangle (2 corners) · Polygon (corners) click every corner, click the first again to close · Pick room polyline closed polylines, also inside an xref · All polylines on a layer pick one room polyline and every closed polyline on its layer becomes a room · Window select window over room polylines · Whole floor (walls + glass) every room of the floor from the wall layers.

The first time you use Click inside room, the palette asks Tell me the wall layer (once). Click Click a wall line and click any wall in the drawing: rooms are then found from the walls only, with door gaps closed. Skip uses the CAD boundary trace instead (door openings may leak).

Now work in the drawing — the palette waits while you click. Click inside as many rooms as you like and press Enter. Room names come from the texts inside each room.

Whole floor asks three layers, one click each: the wall layer, the glass / window layer (No glass layer if none) and a room-name text (Skip names if none). Every closed room of the floor is found at once.

8Lighting
Luminaires for the required lux of every room — code lux per room type, layout on the grid, preview, then placed as blocks with the lux written back.
Drive home → Lighting (or DLL). Check the settings: ceiling height, code (Indian NBC / IS / CPWD or International IEC / EN) and the luminaire from the library. Click Confirm.

Select the room(s) — any tile of the room picker (section 7).

Required lux & rotation — rooms are grouped by type with the code value filled in (NBC 2016 / IS 3646, or EN 12464-1). Change the room type or type a different lux to override. Choose the rotation: Auto (best spacing), 0°, 90° or Angle. Click Place luminaires.

Check the preview — the layout shows in cyan in the drawing; nothing is drawn yet. Place them, Change (back one step) or Place — no more previews.

Done ✔ — per room: number of luminaires, average lux against the target, ✔ or ⚠. Next: Next room(s) with the same settings, Wiring & looping, Change settings, Another tool, Change / undo or Finish.

9Power points
Sockets by room type for the socket standard of the country, snapped to the walls.
Drive home → Power points (DLP). Settings: ceiling height, code and Socket type — India (6 / 16 A), UK (13 A), EU / Gulf or US (NEMA). Confirm.

Select the room(s).

Check the preview — the points in cyan along the walls. Place them.

Done ✔ — points per room. Move or delete any in the drawing; the wiring reads them as they are. Continue with Wiring & looping.

10Wiring & looping
From the DB to every switch board, the looping of every point, conduit sizes, circuits and the DB schedule — drawn as dashed curves with the home runs labelled.
Drive home → Wiring & looping (DLW), or from the Lighting / Power Done screen. Settings: Conduit (MS medium class or PVC heavy duty) and Installation (concealed in RCC slab and wall chases, surface on RCC, or industrial shed). Confirm.

Where is the DB? — Click the DB position and click the wall, or Keep the DB placed before. No DB yet assumes the floor centre.

Switch boards — the screen says how many rooms with points have no board. Click each board (one click per room, Esc skips a room), Place them for me (on the wall towards the DB) or Loop without boards (those rooms get a TO DB arrow).

When every room has its board the third tile reads Loop now. Move any board in the drawing first if you like — its new position is read back.

Wiring done ✔ — circuits, loops, home runs, conduit sizes and the DB summary. Details & legend places the typical details and the legend with this floor’s quantities. Loop again after moving boards or points — the old looping is replaced.

11Fire alarm devices
Smoke / heat detectors, call points and sounders in the selected rooms by the code spacing.
Drive home → Fire alarm (DLF). Settings: ceiling height and code. Confirm.

Select the room(s).

Done ✔ — devices per room. Next: Loops, zones & schematic (section 12).

12Fire alarm loops, zones and schematic
Zones, loop addressing, isolators and cable routes for the devices placed by DesignLink or for the drawing’s own blocks — then the schematic and typical details.
Drive home → Fire alarm loops (DLFL). Settings: System (addressable loops or conventional zones), Loop wiring (Class A back to the panel, Class B open), Devices per loop (panel capacity, 125) and the zone / loop number to start at. Confirm.

Which fire alarm devices? — Devices placed by DesignLink or Blocks already in the drawing.

For your own blocks, one screen per kind: Click a smoke detector block and click one in the drawing — every copy is taken. Then heat detector, multi-sensor, call point, sounder, strobe and interface module: click one, Keep the last one used, or None in this drawing.

Which part of the drawing? — Whole drawing or A window (2 corners) for one floor / wing.

Where is the fire alarm panel? — Click the panel position (FACP on the wall) or Not on this floor (the loop starts at the riser).

Fire alarm ✔ — zones with areas, loops with addresses and lengths, cable, isolators. Addresses go into the blocks’ TAG attribute (or as text beside them). Schematic + legend and Typical details place sheets at a picked corner. The next floor continues the zone and loop numbers.

13CCTV, Data / Tel, PA speakers, Wi-Fi
The same three screens for each ELV system: settings → rooms → done.
Drive home → CCTV, Data / Tel, PA speakers or Wi-Fi. Check the ceiling height and code, Confirm.

Select the room(s).

Done ✔ — devices per room. Cabling to racks, PoE and rack elevations: ELV cabling & racks (section 16). Tags and zones for a whole floor: expert view → ELV → Tag & zone this floor.




14Sprinklers
Heads by hazard and room use → move or add by hand → pipe every head (range, cross and main pipes sized, remote-area check) → details and legend.
Drive home → Sprinklers (DLS). Settings (also: pipe drawing single line or double line at true OD with fittings and joint marks, false-ceiling void for the drops, beam clearance, the IS 15105 design area and 32 mm room feed): hazard where the room use is not known, head type (pendent, upright, up + down for false ceilings, concealed, sidewall), temperature rating, pipe joints (threaded / welded / grooved) and supports (rigid or wire rope, RCC or shed). Confirm.

Sprinkler symbols — the DesignLink symbol, or click a tile and pick your own head block in the drawing. Continue — select rooms.

Select the rooms, then Rooms by use: hazard, head type and temperature are suggested from the room names (kitchen 93 °C, boiler 141 °C, parking and stores OH …). Change any value and click Place sprinklers.

Beams — Click a beam line (every line on that layer is a beam edge), Keep the layer from last time, or No beams / flat slab. Uprights — and the upright of every up + down pair — keep the clearance set in the settings (0.45 m by default) from every beam; the pendent stays on the grid. An up + down pair is drawn as two symbols: the pendent, and the upright 0.75 m above it — move the upright freely; up to 1.5 m away it still counts as the same pair.
Sprinklers — heads per room with the spacing. Move, copy or delete heads in the drawing as you like. Add heads by hand (one per click, Esc ends) or More rooms.

Pipe all heads → Where is the sprinkler riser? — Click the riser point (floor control valve), Same riser as before or Let the tool choose.

Main header route — Draw the main route (click along the corridor, Enter; then draw branches, Enter on an empty line when done), Pick polyline(s) already drawn, Same route as before or Let the tool route it (corridors by name, else the shortest path from the riser). Rooms are fed by square drops from the main.
Every head on the sprinkler layer is piped: zones, pipe metres per size, remote-area flow and pressure, fittings and hangers, checks. Moved heads? Pipe all heads again — the old piping is replaced. Details & legend places installation details with the quantities.

15Toilet plumbing
From the fixture blocks already in the drawing: soil, waste, vent, cold, flushing, hot and RO pipes to the shaft, sized and drawn, with wall elevations, details and legend.
Drive home → Toilet plumbing (DLTO). Settings: drainage (two-pipe or single stack; uPVC SWR, cast iron, HDPE), water pipes · flushing (CPVC / PPR / GI / copper; cistern or flush valves), systems, fixtures per trap, drawings (a sheet per system or in place; geysers or central hot water). Confirm.

One screen per fixture: Click a WC — click one WC block in the drawing; every copy becomes a fixture. Then wash basin, urinal, shower, bath tub, sink, floor trap and ablution tap (None in these toilets when absent).

Which toilets? — Window around the toilets or Whole drawing.

Plumbing shaft — Draw the shaft (2 corners); add more shafts if needed, then Continue.

Toilet rooms (optional) — pick the toilet rooms, or Skip (walls are found from the fixtures).

Settings → Pipe drawing: P-line at true OD + fittings (default) draws every pipe at its outside diameter with bends, wyes / tees and reducers — the drainage as it is laid: WCs, basins and urinals on 45° branches into a main set back from the wall, 45° bend pairs, invert levels (IL) at every branch and '100 Ø UP TO WC' at every outlet; Double line or Single line as alternatives. Sunken slab depth is checked against the invert levels.
Isometrics places the drainage isometric (soil / waste / vent with sizes and IL) and the water-supply isometric (CW / flushing / HW / RO with header and outlet heights) at a picked corner. The detail sheets now include the shaft plan with this project's stacks and risers.
Toilets ✔ — fixtures, shaft groups, systems, pipe sizes and fittings. Elevations, details & legend places the wall elevations and details. Draw again after moving fixtures or the shaft.

16ELV cabling & racks
Cameras, data outlets, access points and readers cabled to the racks along the tray: channel lengths checked, PoE budget, switch and patch-panel count, rack elevations and the schematic.
Drive home → ELV cabling & racks (DLEL). Check the settings — cable, containment, max channel length, PoE budget basis, spare ports, patch panel size, switch type. Confirm.

Pick the ELV devices — Devices placed by DesignLink or Blocks already in the drawing (click one camera, outlet, AP, reader …; every copy is read).

Click each rack (floor IDF / server rack), Enter when done, then Continue.

Draw / pick the cable tray route(s) — Pick a polyline / line or Click the points (Enter ends); add more routes, then Continue.

Check the preview in cyan → Place them.

ELV cabling & racks ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

17Lightning & earthing
Air termination on the roof (mesh / rods), down conductors, ring earth and pits by LPS class, equipment earthing with strip sizes from the fault level.
Drive home → Lightning & earthing (DLEA). Check the settings — LPS class, air termination, roof, conductor, earth electrode, soil resistivity, target earth resistance, fault level for the earth strips. Confirm.

Draw the roof outline — click inside, two corners, every corner or pick the roof polyline.

Building height (m) → Continue.

Click roof equipment / parapet corners to protect (Enter when done), or Skip.

Equipment to earth — transformer, DG, LT panel, lift, UPS … blocks in the drawing, or Skip.

Earth pit zone (optional) — Two corners or Skip (pits around the building).

Check the preview in cyan → Place them.

Lightning & earthing ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

18Gas suppression
FM-200, Novec 1230 or IG-541: agent quantity for the room volume (with void depths), nozzles, piping, cylinder bank, cross-zoned detectors and pressure relief.
Drive home → Gas suppression (DLGS). Check the settings — agent, hazard class, design concentration, minimum room temperature, site altitude, protect, cylinder size, reserve, several rooms, enclosure strength. Confirm.

Select the room(s) to protect — the room picker.

Room height (slab to slab or ceiling) → Continue.

False ceiling / raised floor void depths, e.g. 0.6, 0.45 → Continue or Skip.

Click the cylinder bank position.

Existing smoke / heat detectors in the rooms, or Skip for new cross-zoned detectors.

Check the preview in cyan → Place them.

Gas suppression ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

19Car-park ventilation
Jet fans for the normal and fire / smoke rates, exhaust and supply shafts, CO sensors and smoke zones for the car-park outline.
Drive home → Car-park ventilation (DLCP). Check the settings — normal ventilation rate, fire / smoke mode rate, jet fan thrust and type, CO sensor coverage, smoke zone max area, supply air as % of exhaust, clear height. Confirm.

Draw the car-park outline (click every corner, two corners or pick the polyline).

Clear height → Continue.

Click the ramp / entry openings (fresh air), Enter when done → Continue.

Click the exhaust shaft position(s) → Continue.

Click the fresh-air (supply) shaft position(s) → Continue or Skip.

Pick / draw big beams or walls that block the airflow → Continue or Skip.

Check the preview in cyan → Place them.

Car-park ventilation ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

20HVAC ducts & units
Diffusers per room from the heat load, duct routing along the corridor and sizing, or VRF / FCU units with refrigerant and drain piping.
Drive home → HVAC ducts & units (DLHV). Check the settings — system, load basis, duct sizing, diffuser type, max throw, duct material, duct insulation, refrigerant pipe. Confirm.

Select the air-conditioned rooms — the room picker.

Heat-load project code (optional, from the Heat load tool) → Continue or Skip.

Click the AHU / FCU / outdoor unit position.

Draw / pick the main duct or pipe route along the corridor — polyline or points.

Pick existing indoor units, diffusers and return grilles, or Skip to lay them out.

Check the preview in cyan → Place them.

HVAC ducts & units ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

21Cable tray & feeders
LT feeders routed on the tray: fill, tray size, tiers and segregation, sections and the cable schedule — feeders from a voltage-drop project or typed.
Drive home → Cable tray & feeders (DLT). Check the settings — tray type, material, fill basis, max tray width, tiers allowed, segregation, support spacing, feeders from, cable route lines on the plan. Confirm.

Draw / pick the cable tray route(s) → Continue.

Panels and DBs on this floor — click one panel / DB block (its TAG attribute is the name); every copy is read.

Voltage-drop project code (feeders from the VD tool) → Continue or Skip.

Or type feeders, one per line: MLTP > LDB-1 : 4C x 25 Sq.mm, Al → Continue.

Click the main LT panel if it is not a block, or Skip.

Check the preview in cyan → Place them.

Cable tray & feeders ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

22HVLS fans
Fan count and layout for the area and its racks, with the air-speed map at the occupied plane.
Drive home → HVLS fans (DLHF). Check the settings — fan size, target air speed at the plane, target coverage, occupied plane height. Confirm.

Draw the area outline (click every corner, two corners or pick the polyline).

Clear height to the underside of the roof structure → Continue.

Pick the racks / equipment outlines (closed polylines) or walls → Continue or Skip.

Height of the racks / obstructions → Continue.

Existing HVLS fan blocks, or Skip to lay the fans out automatically.

Check the preview in cyan → Place them.

HVLS fans ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

23Change what was placed
Edit after placing without starting over: every DesignLink block keeps its link to the design.
Type DLE (or Drive home → Change & number, or Change / undo on any Done screen). Thirteen tools:

Re-read & re-route — after moving, copying or deleting blocks by hand: the record is matched to the drawing (moved / copied / deleted counts) and the screen offers to re-route what depends on it: Loop again, fire alarm loops, sprinkler piping, or the last tool.

Re-array a room — the room changed size: pick the room as it is now and its devices are laid out again.

Align devices — window over devices, then One row (same Y), One column (same X), Rows & columns (snap to the nearest row / column) or Equal spacing (ends stay).

Replace symbol — window over DesignLink devices, pick the new symbol: same place and angle. For any other block use DLBRE.

Outlets along a wall — sockets, switches, data / tel / TV or other wall devices along a wall you pick, at the spacing you type.

Connect blocks — Two blocks square route around other blocks, Two blocks — I shape it (the route follows the mouse), Chain several (first → … → last: data, PA …) or straight.

Junction boxes (after looping) — boxes at the loop branch points, previewed first. Home runs — DB → each circuit with a gap between parallel runs.

Undo last run — removes what the last run drew and brings back what it erased; changes you made by hand afterwards stay. DLU opens it directly.

24Numbering
Tags in the order you want, written into the blocks.
Type DLN. Set the prefix, start, step and the attribute (TAG, CKT …). Then the order: Click order (one click per device), Rows, left → right, Snake (alternate rows), Columns, top → bottom or Along the path (nearest next). Fix a run renumbers part of a run; Phase colours colours loops R / Y / B.

25Cable tray control
Draw and edit cable trays as real trays: width, type, fittings with radius, supports and the tray Q.S.
Type DLCT (or Drive home → Cable tray control). Choose the default width, depth and type (ladder, perforated, …) at the bottom, and tick Draw supports, Hatch, Covers. Draw from polylines turns centre-lines into trays; Add section draws by points (a branch when it starts on a tray).

Once a tray exists: Move section (2 points), Change width, Remove section, Add reducer, Change tray type, Join / extend, Undo change; Tray Q.S places the quantity table and sends the BOQ lines.

Fitting radius — inner radius of bends (mm) → Apply. Supports — support span (mm) → Apply.

26Loop optimiser
The shortest fire-alarm (or any) loops round the columns and shafts, with addresses written into the blocks.
Type DLLO. 1 · Loop devices — Select window over the devices (or FA takes the fire alarm devices placed); switch block names on / off with the chips. 2 · Panel — Click the panel. 3 · Avoid — Select the column / shaft blocks. Set the direction, Class A / B, devices per loop and the effort (Fast / Better / Best), tick Write addresses, then Run.

Preview in cyan → Place them. Loops ✔ shows each loop’s devices and length and the metres saved against the next-nearest order. Run again after moving devices — the old loops are replaced.
27Quantities
Counts and lengths straight from the drawing — as a table in the drawing or into the CPWD DSR BOQ.
Type DLQ. What do you want to count? — Count blocks by name, Blocks by layer, By attribute (TAG, CKT, any tag), Dynamic states (visibility state), Length by layer (lines, polylines, arcs), Average point length (ceiling / wall points from the looping), Tray Q.S and Open the DSR BOQ.

Which part of the drawing? — Whole drawing, A window or Inside a polyline (a room, a floor, a zone). Blocks inside xrefs are counted too.

The result table shows on screen. Then place it as a table in the drawing (click the top-left corner) or send it to the DSR BOQ — sending the same kind again replaces it.
28DIALux
Rooms and luminaires to DIALux evo, and a DIALux layout back into DesignLink.
Type DLDX. Export to DIALux (.stf) — every room with its outline, height and luminaires as an STF file to open in DIALux evo. Import a DIALux evo layout — click one luminaire block of the DIALux plan, choose the part of the drawing, tell which DesignLink luminaire it is, then Replace with my symbol or Keep the DIALux blocks.

29CPWD DSR BOQ
Everything placed and counted, priced on CPWD DSR in the 5-sheet BOQ (Summary, BOQ, Take Off, Rate Analysis DSR and Non-DSR).
Drive home → CPWD DSR BOQ (or expert view → Schematics → CPWD DSR BOQ). With several drawings open: Include all open drawings? — All open drawings (one BOQ, a Take Off per drawing / floor) or Only this drawing. A drawing without a DesignLink session is marked — open Daily work in it once.

The DSR BOQ page opens in the palette with the items, quantities and rates; download the Excel (needs a credit).
30The expert view (all buttons)
The same engine as Drive mode, every button on one page — for quick single actions.
In Drive mode click the dashboard icon (top right). The top bar: floor list and + (add a floor), ceiling height, socket regime (India / UK / EU / Gulf / US), codes (Indian / International), Drive (back to drive mode), sign-in. Tabs: Lighting · Power · ELV · Schematics.

The room card: the selection chips start the command at once — Click inside, Rectangle, Polygon, Pick polyline, Same layer, Window; the big button repeats it. The card shows the room name, type, lux, ceiling and devices. Add ceiling zone, Ceiling grid…, Symbols… (your own blocks) and Clear room.

Lighting — search and click a luminaire, choose the rotation, then Auto place for the room’s lux (result: count, W, LPD, Ē, Uo, emergency) or Place one per click (lux updates after every click). With several rooms: Auto place in all selected rooms.

Power — choose a point type (fan, sockets by regime, AC point, isolator, industrial, floor box), then Place by click (wall-snapped) or Auto for this room.

Switchboard & circuits — Place switchboard (click the wall), Place / move DB, then Circuit & loop this floor: the circuit table (Ckt · Kind · Pts · W · MCB · mm² · Ph · Rooms) and the looping drawn. Details & legend places the detail sheet.

ELV — system chips (fire alarm, PA, CCTV, data, telephone, MATV, Wi-Fi, access control) and their devices; Place by click, Auto for this room, Auto for all rooms and Tag & zone this floor.

Schematics — the floor summary and the BOQ table. Choose a system, then Schematic into drawing, Schematic DXF, Schedules Excel or CPWD DSR BOQ (the Excel files need a credit).

31Quick tools
57 drafting tools for everyday CAD work — selection, blocks, attributes, lines, dimensions, text, plotting and xrefs. Click a tile and answer in the drawing, or type the command.
Type DLQT (or Drive home → Quick tools). Tabs on top: Select · Blocks · Block+ · Attrib · Lines · Dims · Text · Plot. Each tile shows its command name (e.g. DLSSB) — click it, then answer on the command line. Typed commands work without the palette; DLHELP lists them all.

Select

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Similar DLSS | Select every object like the picked one: same type + layer + colour (and same block name for blocks). | > Select an object: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
| Same layer DLSSL | Select every object on the same layer as the picked one. | > Select an object: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
| Same colour DLSSC | Select every object with the same colour as the picked one. | > Select an object: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
| Same block DLSSB | Select every block with the same name as the picked block. | > Select a block: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
| Attribute value DLSSA | Select all blocks carrying the same attribute (tag + value, or tag only). | > Click the attribute text inside a block: > Match <TAG> [Value/Tag] (value = "<value>") <Value>: |
| Blocks in polyline DLSSP | Select the blocks with the same name that lie inside a closed polyline / circle. | > Select a block: > Select the closed polyline / circle around the area: |
| Visibility state DLSSV | Select blocks with the same name and the same dynamic visibility state. | > Select a block: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
| By properties DLSSO | Select objects matching the picked one on a chosen set of properties. | > Match which properties — letters T type, L layer, C colour, Y linetype, B block, W lineweight, X text <TL>: > Select an object: > Where [All/Window/Polyline] <All>: > [Window] Select the area (window): > [Polyline] Select the closed polyline / circle around the area: |
Blocks

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Replace blocks DLBRE | Replace selected blocks by another block, keeping position, angle, scale, layer and attribute values. | > Select the blocks to replace: > Replacement block [Pick/Name] <Pick>: > [Pick] Select the replacement block: > [Name] Block name: > Scale [Keep/One] <Keep>: |
| Replace in drawings DLBRB | Replace a block in other (closed) drawings by a block from this drawing. | > New block (from this drawing) [Pick/Name] <Pick>: > [Pick] Select the new block (from this drawing): > [Name] Block name: > Block to replace in the other drawings <<new block name>>: > File dialog 'Drawings where <target> becomes <new>' (Drawings (*.dwg), multi-select) |
| Rename all DLRBB | Rename a block definition (every copy in the drawing). | > Select the block to rename (every copy in the drawing): > New name for <old>: |
| Rename these DLRB | Give only the selected copies of a block a new name (the others keep the old one). | > Select the block copies to give a new name (others keep the old one): > New name for the selected <old> <<old>_A>: |
| Duplicate DLDB | Duplicate a block definition under a new name. | > Select the block to duplicate: > Name of the copy <<name>_COPY>: > Switch the picked block to the copy [Yes/No] <No>: |
| Quick block DLQB | Quick block: turn selected objects into a block in one go. | > Select the objects for the new block: > Block name <QB_HHmmss>: > Base point: |
| Base point DLCBPR | Change a block's base point without moving any copy in the drawing. | > Select the block: > New base point: |
| Default rotation DLROT0 | Make a block's present rotation its normal 0° rotation. | > Select a block whose present rotation should become its normal (0°) rotation: |
| Default scale DLSC0 | Make a block's present scale its scale 1. | > Select a block whose present scale should become its scale 1: |
| Rotate many DLROTM | Rotate many blocks, each about its own base point (add an angle or set an absolute angle). | > Select the blocks to rotate (each about its own base point): > Angle [Add/Set] <Add>: > [Add] Rotate by (degrees, + = anticlockwise): (number; default 90; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it) > [Set] Set every block to (degrees): (number; default 90; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it) > Keep attribute text readable [Yes/No] <Yes>: |
| Rescale many DLRESB | Rescale many blocks, each about its own base point. | > Select the blocks to rescale (each about its own base point): > Factor (1.5 = 50 % bigger): (number; default 1.5; must be > 0; the CAD shows the default as <…>, Enter accepts it) |
| Dynamic → static DLD2R | Convert dynamic blocks to static blocks (one static block per dynamic block + visibility state). | > Select the dynamic blocks to make static: |
Block+

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Add to block DLADD2B | Add objects to a block definition without the block editor (every copy changes). | > Select the objects to add to a block: > Select the block to add them to: > Keep the originals in the drawing [Yes/No] <No>: |
| Remove from block DLREMB | Remove objects from a block definition by clicking them inside a block (repeats). | > Leave a copy of each removed object in the drawing [Yes/No] <No>: > Click an object inside a block to remove it (Enter to finish): |
| Trim lines in blocks DLABBM | Cut the lines/polylines/arcs that run through blocks at the block outline. | > Select the blocks (lines running through them are cut at their outline): > Extra gap around each block: (number; default 0; zero allowed; the CAD shows the default as <…>, Enter accepts it) |
| Restore exploded DLJEB | Restore exploded blocks: find the exploded pieces of a block among selected objects and put block references back. | > Block to restore [Pick/Name] <Pick>: > [Pick] Select the block to restore: > [Name] Block name: > Select the exploded objects (a window over them): > The copies may be scaled [Yes/No] <No>: |
| Flatten Z = 0 DLFLATB | Flatten blocks to Z = 0 (their contents, nested blocks and the references). | > Flatten [Selected/All] blocks <Selected>: > [Selected] Select the blocks to flatten: |
| Make explodable DLEXPL | Make every block in the drawing explodable. | |
| Colour / layer inside DLBCL | Set the colour and/or layer of the objects inside blocks (nested too). | > Select the blocks: > Colour of the objects inside [Block/Layer/Number/Keep] (ByBlock, ByLayer, a colour, unchanged) <Block>: > [Number] Colour number (1-255): (number; default 7; the CAD shows the default as <…>, Enter accepts it) > Layer of the objects inside [Zero/Name/Keep] <Zero>: > [Name] Layer name <0>: |
| Block → xref DLBTX | Turn a block into an xref: save it as a DWG and replace every copy by the xref. | > Select the block to turn into an xref: > Save the block as <<drawing folder or My Documents>\<name>.dwg>: > [file exists] <file>.dwg exists — overwrite [Yes/No] <No>: |
Attributes

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Change attributes DLATTC | Change attributes of selected blocks: rotation, height, colour, upright or layer. | > Select the blocks: > Attribute tag (* = all) <*>: > Change [Rotation/Height/Colour/Upright/Layer] <Upright>: > [Rotation] Text angle in the drawing (degrees): (number; default 0; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it) > [Height] Text height: (number; default TEXTSIZE if > 0, else 250 mm in drawing units; the CAD shows the default as <…>, Enter accepts it) > [Colour] Colour number (0 = ByBlock, 256 = ByLayer): (number; default 256; the CAD shows the default as <…>, Enter accepts it) > [Layer] Layer <0>: |
| Hide attributes DLINVATT | Hide attributes (selected blocks or all blocks). | > [Select/All] blocks <Select>: > [Select] Select the blocks: > Attribute tag (* = all) <*>: |
| Show attributes DLSHOWATT | Show attributes again (selected blocks or all blocks). | > [Select/All] blocks <Select>: > [Select] Select the blocks: > Attribute tag (* = all) <*>: |
Lines

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Fillet polylines DLMF | Fillet every corner of selected polylines with one radius. | > Select the polylines to fillet: > Fillet radius: (number; default FILLETRAD if > 0, else 300 mm in drawing units; the CAD shows the default as <…>, Enter accepts it) |
| Fillet 2 sets DLFF | Fillet two sets of parallel lines with concentric bends (e.g. a bundle of conduits turning a corner). | > Select the first set of parallel lines: > Select the second set of parallel lines: > Radius of the inner bend: (number; default FILLETRAD if > 0, else 300 mm in drawing units; the CAD shows the default as <…>, Enter accepts it) |
| Equal spacing DLOL | Space parallel lines/polylines equally between the outer two. | > Select the parallel lines / polylines (the outer two stay): |
| Break at crossings DLBBM | Break lines at their crossings with a gap. | > Select the lines / polylines / arcs: > Gap at each crossing: (number; default 150 mm in drawing units; the CAD shows the default as <…>, Enter accepts it) > At a crossing break the [Later/Horizontal/Vertical] one <Later>: |
| Close gaps DLGAP | Close gaps in broken straight lines (merge collinear pieces). | > Select the broken lines: > Largest gap to close: (number; default 500 mm in drawing units; the CAD shows the default as <…>, Enter accepts it) |
| Total length DLTLEN | Total length of selected curves by layer (optionally as a table). | > Select lines, polylines, arcs …: > Place a table [Yes/No] <No>: > [Yes] Table position (top-left): |
| 90° polyline DL3P | Draw 90° (L-shaped) polylines from start point, end point and the side of the bend (repeats). | > Start point (Enter to finish): > End point: > Click on the side of the bend: |
| Join → polyline DLPJL | Join lines and arcs into polylines. | > Select the lines and arcs to join: > Join ends closer than: (number; default 1 mm in drawing units; zero allowed; the CAD shows the default as <…>, Enter accepts it) |
Dimensions

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Chain between blocks DLBD | Chain dimensions between blocks in a row. | > Select the blocks in a row: > Position of the dimension line: |
| Block → point X + Y DLNN | Dimension from a block to a wall / column point in X and Y (repeats). | > Select a block (Enter to finish): > Point on the wall / column: |
| Block → point X DLHH | Dimension from a block to a wall / column point — horizontal (X) only (repeats). | > Select a block (Enter to finish): > Point on the wall / column: |
| Block → point Y DLVV | Dimension from a block to a wall / column point — vertical (Y) only (repeats). | > Select a block (Enter to finish): > Point on the wall / column: |
Text

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Add a line DLADDTEXT | Add a line of text at the top or bottom of texts, mtexts or multileaders. | > Select texts, mtexts or multileaders: > Line to add: > Add it at the [Top/Bottom] <Bottom>: |
| Remove a line DLRLINE | Remove the first, last or n-th line from mtexts or multileaders. | > Select mtexts or multileaders: > Remove the [First/Last/Number] line <Last>: > [Number] Line number (1 = top): (number; default 2; the CAD shows the default as <…>, Enter accepts it) |
| Text → leader DLAM | Turn texts into multileaders — one arrow point per text. | > Select the texts to turn into leaders: > Arrow point for "<first 30 characters of the text>…" (Enter to stop): |
| Align / mirror leaders DLMM | Align or mirror multileader texts. | > Select the multileaders: > [Align/Mirror] the text <Align>: > [Align] Line the texts up [Vertical/Horizontal] <Vertical>: > [Align, Vertical] Click where the text edges should line up: > [Align, Horizontal] Click the height for the texts: |
| Leader colour DLMLC | Recolour multileaders (entity, leader line and text). | > Select the multileaders: > Colour number (1-255, 256 = ByLayer): (number; default 1; the CAD shows the default as <…>, Enter accepts it) |
| Match leaders DLFITMLD | Make multileaders match a reference multileader (text height, text width, arrow size, landing). | > Select the reference multileader: > Select the multileaders to match it: |
| Find & replace DLBFIND | Find & replace text in this drawing or in many drawings. | > Find: > Replace with (Enter = delete it): > Match upper / lower case [Yes/No] <No>: > Replace in [Drawing/Files] <Drawing>: > [Files] File dialog 'Drawings to change' (Drawings (*.dwg), multi-select) |
| Replace from Excel DLTFIND | Find & replace with a word list (Excel columns from the clipboard, or an .xlsx/.csv/.txt file). | > Word list from [Clipboard/File] (column A = find, B = replace) <Clipboard>: > [File] File dialog 'Word list: column A find, column B replace' (Excel / CSV (*.xlsx;*.csv;*.txt)) > Match upper / lower case [Yes/No] <No>: > Replace in [Drawing/Files] <Drawing>: > [Files] File dialog 'Drawings to change' (Drawings (*.dwg), multi-select) |
Plot & xref

| Tile · command | What it does | Command line, in order |
|---|---|---|
| Plot all layouts DLLPLOT | Plot all layouts (or the current one), each with its own page setup. | > Plot [All/Current] layout(s) — <n> in the drawing, each with its own page setup <All>: |
| Printer for all DLLPRIN | Set the same printer / plotter on every layout. | > (numbered list of plot devices, current marked '(now)') > Number of the printer / plotter (1-<n>): (number; default the device of the first layout; the CAD shows the default as <…>, Enter accepts it) |
| Pen table for all DLLPEN | Set the same pen table (.ctb / .stb) on every layout. | > (numbered list of plot style tables, current marked '(now)') > Number of the pen table (.ctb / .stb) (1-<n>): (number; default the table of the first layout; the CAD shows the default as <…>, Enter accepts it) |
| Layouts → drawings DLL2D | Split layouts into separate drawings (one DWG per layout). | > [unsaved changes] The drawing has unsaved changes that will not be included — go on [Yes/No] <No>: > Folder for the new drawings <<drawing folder>>: |
| Xref colour DLCXR | Set the colour of xref layers (all xrefs or one picked xref). | > Colour [Pick/All] xrefs <All>: > [Pick] Select the xref: > Colour number (8 = grey, 252 = light grey): (number; default 8; the CAD shows the default as <…>, Enter accepts it) |
| Bind all xrefs DLTBIND | Bind all loaded xrefs. | > [Insert/Bind] (Insert merges layer names, Bind keeps the xref name$0$ prefix) <Insert>: |
32Place a drawing from your projects
Drop the DXF of any saved calc project into the open drawing — SLD, panel GA, UGT, STP, roof drainage, sewer / water / fire networks, sprinkler and lighting layouts … Units are converted to the drawing’s units.
Tool menu → Place a drawing from my projects. Signed in, My projects lists every project with a drawing — click Place. Or type a project code (from the website URL, ?p=…) and click Place.

Click the insertion point in the drawing. The log shows “<drawing> <code>: n object(s) placed”. Free in the plugin.
33Sewer and storm-water wizards
Six steps in the palette: pipes and manholes read from the drawing → CPHEEO / rational-method design → labels, plan and L-sections back in the drawing.
Tool menu → Sewer network (palette wizard). 1. Project — name, code regime, design standard, design mode (Design & Build or Design Only — check what is drawn), profile control, drawing units, plot scale, pipe material → Create project.

Storm-water adds the section policy (pipe → box → trapezoid by flow), lining, side slope and freeboard.

2. Network — Select in drawing the lines and manhole symbols (Design Only: also the texts), By layers… or Whole drawing → Build network; join gaps and fix pieces without an outfall.
3. Outfall — Pick outfall in drawing. 4. Levels — click a level text, along an alignment, or nearest levels; type the rest. 5. Loads (buildings / point loads) or Catchments (IDF + rational method).
6. Design — Run design (or Run check) → reaches and manholes tables. Label the design in the drawing, the plan + L-sections and sheet sets are free in the plugin; the report and Excel need a credit.
34Troubleshooting
Most problems are a closed palette, a missing drawing or the units.
| You see | Do this |
|---|---|
| Typed DESIGNLINK, no palette | Wait a few seconds, then DLWINDOW. Still nothing: DLDIAG and send the text to support. |
| “WebView2 did not start in 25 s” | Close every AutoCAD / ZWCAD, delete %LOCALAPPDATA%\DesignLink\CAD\WebView2, open again. |
| “WebView2 could not start” / blank palette | Run Setup again (it installs the Microsoft Edge WebView2 runtime). |
| “Could not load the page — check internet / proxy” | The PC cannot reach calc.designlink.in; check the connection, then click the grey strip to retry. |
| “no reply from CAD (is a drawing open?)” | Open a drawing (or click into it) and try again. |
| Rooms come out 1000× too big or small | Setup → Units & scale and pick the unit that gives the real size. |
| “no closed boundary around that point” | Set the wall layer (Click a wall line) or use Rectangle / Polygon / Pick polyline for that room. |
| A plugin file is missing / wrong build | Close CAD, run Setup again, send DLDIAG if it repeats. |
| Plugin not loading in AutoCAD 2026 / 2027 | Run the current Setup (it installs into Program Files), restart AutoCAD. |
| Plugin not loading in a new ZWCAD | NETLOAD the ZWCAD DLL once and type DLAUTOLOAD, or run Setup again. |
| Sign-in code not arriving | Check spam; the code is valid 10 minutes — sign in again for a new one. |
35Every command
All commands the plugin adds to AutoCAD / ZWCAD. The prompts are what the command line shows.
Palette and support
| Command | What it does |
|---|---|
| DESIGNLINK | Open the DesignLink palette (calc.designlink.in in CAD mode). |
| DLPALETTE | Alias of DESIGNLINK — open/show the docked palette. |
| DLWINDOW | Open DesignLink in a separate floating window instead of the docked palette. |
| DLHOME | Show the palette and go to the DesignLink CAD home page. |
| DLLOGOUT | Sign out of DesignLink in the palette. |
| DLABOUT | Print plugin version, host CAD/version, .NET runtime and the main commands. |
| DLDIAG | Diagnostics: print versions, dependency check, WebView2 runtime and the last 30 log lines. |
| DLAUTOLOAD | Make the CAD load the plugin at every start. |
Drive shortcuts and selection
| Command | What it does |
|---|---|
| DLSS | Select every object like the picked one: same type + layer + colour (and same block name for blocks). |
| DLSSL | Select every object on the same layer as the picked one. |
| DLSSC | Select every object with the same colour as the picked one. |
| DLSSB | Select every block with the same name as the picked block. |
| DLSSP | Select the blocks with the same name that lie inside a closed polyline / circle. |
| DLSSV | Select blocks with the same name and the same dynamic visibility state. |
| DLSSA | Select all blocks carrying the same attribute (tag + value, or tag only). |
| DLSSO | Select objects matching the picked one on a chosen set of properties. |
| DLHELP | List all quick tools and drive shortcuts on the command line. |
| DLCHECK | Self-test of this CAD: runs every drawing-only bridge method on a scratch layer and removes the test objects again. |
| DLQT | Open the palette on Quick tools. |
| DLD | Drive mode → Drive home. |
| DLL | Drive mode → Lighting. |
| DLP | Drive mode → Power points. |
| DLF | Drive mode → Fire alarm. |
| DLFL | Drive mode → Fire alarm loops. |
| DLS | Drive mode → Sprinklers. |
| DLW | Drive mode → Wiring & looping. |
| DLT | Drive mode → Cable tray & feeders. |
| DLTO | Drive mode → Toilet plumbing. |
| DLHV | Drive mode → HVAC ducts & units. |
| DLCP | Drive mode → Car-park ventilation. |
| DLEA | Drive mode → Lightning & earthing. |
| DLGS | Drive mode → Gas suppression. |
| DLEL | Drive mode → ELV cabling & racks. |
| DLHF | Drive mode → HVLS fans. |
| DLE | Drive mode → Change what was placed. |
| DLN | Drive mode → Number the devices. |
| DLU | Drive mode → Undo the last run?. |
| DLCT | Drive mode → Cable tray control. |
| DLLO | Drive mode → Loops. |
| DLAX | Drive mode → Building direction. |
| DLQ | Drive mode → Quantities. |
| DLDX | Drive mode → DIALux. |
| DLSET | Drive mode → Setup. |
Blocks
| Command | What it does |
|---|---|
| DLRBB | Rename a block definition (every copy in the drawing). |
| DLRB | Give only the selected copies of a block a new name (the others keep the old one). |
| DLDB | Duplicate a block definition under a new name. |
| DLCBPR | Change a block's base point without moving any copy in the drawing. |
| DLROT0 | Make a block's present rotation its normal 0° rotation. |
| DLSC0 | Make a block's present scale its scale 1. |
| DLROTM | Rotate many blocks, each about its own base point (add an angle or set an absolute angle). |
| DLRESB | Rescale many blocks, each about its own base point. |
| DLQB | Quick block: turn selected objects into a block in one go. |
| DLADD2B | Add objects to a block definition without the block editor (every copy changes). |
| DLREMB | Remove objects from a block definition by clicking them inside a block (repeats). |
| DLABBM | Cut the lines/polylines/arcs that run through blocks at the block outline. |
| DLFLATB | Flatten blocks to Z = 0 (their contents, nested blocks and the references). |
| DLEXPL | Make every block in the drawing explodable. |
| DLBCL | Set the colour and/or layer of the objects inside blocks (nested too). |
| DLBTX | Turn a block into an xref: save it as a DWG and replace every copy by the xref. |
| DLBRE | Replace selected blocks by another block, keeping position, angle, scale, layer and attribute values. |
| DLBRB | Replace a block in other (closed) drawings by a block from this drawing. |
| DLD2R | Convert dynamic blocks to static blocks (one static block per dynamic block + visibility state). |
| DLJEB | Restore exploded blocks: find the exploded pieces of a block among selected objects and put block references back. |
Lines and dimensions
| Command | What it does |
|---|---|
| DLMF | Fillet every corner of selected polylines with one radius. |
| DLFF | Fillet two sets of parallel lines with concentric bends (e.g. a bundle of conduits turning a corner). |
| DLOL | Space parallel lines/polylines equally between the outer two. |
| DLBBM | Break lines at their crossings with a gap. |
| DLGAP | Close gaps in broken straight lines (merge collinear pieces). |
| DLTLEN | Total length of selected curves by layer (optionally as a table). |
| DL3P | Draw 90° (L-shaped) polylines from start point, end point and the side of the bend (repeats). |
| DLPJL | Join lines and arcs into polylines. |
| DLBD | Chain dimensions between blocks in a row. |
| DLNN | Dimension from a block to a wall / column point in X and Y (repeats). |
| DLHH | Dimension from a block to a wall / column point — horizontal (X) only (repeats). |
| DLVV | Dimension from a block to a wall / column point — vertical (Y) only (repeats). |
Text, plot and xrefs
| Command | What it does |
|---|---|
| DLADDTEXT | Add a line of text at the top or bottom of texts, mtexts or multileaders. |
| DLRLINE | Remove the first, last or n-th line from mtexts or multileaders. |
| DLAM | Turn texts into multileaders — one arrow point per text. |
| DLMM | Align or mirror multileader texts. |
| DLMLC | Recolour multileaders (entity, leader line and text). |
| DLFITMLD | Make multileaders match a reference multileader (text height, text width, arrow size, landing). |
| DLBFIND | Find & replace text in this drawing or in many drawings. |
| DLTFIND | Find & replace with a word list (Excel columns from the clipboard, or an .xlsx/.csv/.txt file). |
| DLCXR | Set the colour of xref layers (all xrefs or one picked xref). |
| DLTBIND | Bind all loaded xrefs. |
| DLLPRIN | Set the same printer / plotter on every layout. |
| DLLPEN | Set the same pen table (.ctb / .stb) on every layout. |
| DLLPLOT | Plot all layouts (or the current one), each with its own page setup. |
| DLL2D | Split layouts into separate drawings (one DWG per layout). |
| DLATTC | Change attributes of selected blocks: rotation, height, colour, upright or layer. |
| DLINVATT | Hide attributes (selected blocks or all blocks). |
| DLSHOWATT | Show attributes again (selected blocks or all blocks). |