designlink calc· CAD plugin guideDownload the pluginPDF
DESIGNLINK CALC · calc.designlink.in

DesignLink CAD plugin

How to use it — click by click, with a screenshot of every screen
For AutoCAD 2023 – 2027 and ZWCAD 2024 – 2026. Lighting, power, wiring, fire alarm, sprinklers, toilets, ELV, earthing, gas suppression, car-park ventilation, HVAC, cable trays, HVLS fans, quantities, DIALux, CPWD DSR BOQ and 57 quick drafting tools — designed and drawn in your own drawing.
Drive mode — What do you want to place?
Drive mode — What do you want to place?
Lighting — required lux & rotation
Lighting — required lux & rotation
Sprinklers — every head piped
Sprinklers — every head piped
Plugin 1.8 · October 2026 · calc.designlink.in/guide/cad

Contents

  1. What you need
  2. Download and install
  3. Open the palette
  4. Sign in, credits and plans
  5. Drive mode and the expert view
  6. First time in a drawing: Setup
  7. Selecting rooms — the same in every tool
  8. Lighting
  9. Power points
  10. Wiring & looping
  11. Fire alarm devices
  12. Fire alarm loops, zones and schematic
  13. CCTV, Data / Tel, PA speakers, Wi-Fi
  14. Sprinklers
  15. Toilet plumbing
  16. ELV cabling & racks
  17. Lightning & earthing
  18. Gas suppression
  19. Car-park ventilation
  20. HVAC ducts & units
  21. Cable tray & feeders
  22. HVLS fans
  23. Change what was placed
  24. Numbering
  25. Cable tray control
  26. Loop optimiser
  27. Quantities
  28. DIALux
  29. CPWD DSR BOQ
  30. The expert view (all buttons)
  31. Quick tools
  32. Place a drawing from your projects
  33. Sewer and storm-water wizards
  34. Troubleshooting
  35. Every command

1What you need

The plugin draws your services into the open AutoCAD or ZWCAD drawing: you pick rooms and points in the drawing, the palette works out the design and draws the result on its own layers.

ItemRequirement
WindowsWindows 10 / 11, 64-bit. Administrator rights to install.
AutoCADAutoCAD 2023, 2024, 2025, 2026 and 2027, including verticals (MEP, Architecture, Electrical, Map 3D, Civil 3D). AutoCAD LT is not supported — LT cannot load plugins.
ZWCADZWCAD 2024, 2025 and 2026.
InternetThe palette pages load from calc.designlink.in, so the PC must be online.
AccountA DesignLink login (company users) or a calc.designlink.in sign-in. The plugin is free to download and use — every drawing it makes is free. Design reports and Excel files (schedules, BOQ) need a design credit or a plan (section 4).
DrawingA plan with walls on their own layer works best. Model space, any units (mm, cm, m, inch, feet) — Setup tells the plugin which one.

2Download and install

One installer covers every supported AutoCAD and ZWCAD on the PC.

1

Download DesignLinkCAD-Setup.exe from calc.designlink.in/cad/download (or use the copy attached to the e-mail).

2

Close every AutoCAD and ZWCAD window. If one is still open, Setup stops with “AutoCAD / ZWCAD is running and has the DesignLink plugin loaded. Close every AutoCAD and ZWCAD window, then press Retry.” Close it and press Retry.

3

Double-click the file and accept the Windows administrator prompt. Click Next / Install with the default folder (C:\Program Files\DesignLink\CAD). If the Microsoft Edge WebView2 runtime is missing, Setup installs it (“Installing Microsoft Edge WebView2 runtime…”).

4

Click Finish. Nothing else to configure — AutoCAD loads the plugin automatically from the next start; ZWCAD is registered for every version found.

Updating: close AutoCAD / ZWCAD and run the new Setup — it replaces the old plugin completely. Uninstall: Windows Settings → Apps → “DesignLink CAD”. To also forget the sign-in, delete the folder %LOCALAPPDATA%\DesignLink\CAD.
ZWCAD installed after the plugin? Type NETLOAD once and pick C:\Program Files\DesignLink\CAD\ZWCAD\DesignLinkCAD.ZWCAD.dll, then type DLAUTOLOAD — from then on it loads by itself. Or simply run Setup again.

3Open the palette

There is no ribbon or menu — everything starts from a typed command.

1

Start AutoCAD / ZWCAD and open your drawing (the palette needs an open drawing).

2

Type DESIGNLINK and press Enter. The DesignLink calc palette docks on the right. A dark bar on top shows the CAD, a green dot and the drawing name with its units. Below it is the tool menu: Drive mode, Daily work, the step-by-step website tools that read the drawing, the sewer / storm wizards and Place a drawing.

DesignLink CAD plugin for AutoCAD and ZWCAD | Design Link calc
DesignLink CAD plugin for AutoCAD and ZWCAD | Design Link calc
3

The Drawing checks at the bottom are a quick test that the palette talks to the drawing: Layers lists every layer with its object count, Pick a point and Read a polyline ask you to click in the drawing.

DesignLink CAD plugin for AutoCAD and ZWCAD | Design Link calc
DesignLink CAD plugin for AutoCAD and ZWCAD | Design Link calc
Palette not showing (seen on some ZWCAD 2024 PCs)? The plugin opens the same page in a floating window by itself; DLWINDOW forces that window. DLHOME brings the palette back to the tool menu from anywhere.
TypeWhat happens
DESIGNLINK or DLPALETTEopen / show the palette
DLDopen Drive mode on its home screen (the fastest way to work)
DLHOMEpalette back to the tool menu
DLWINDOWopen DesignLink in a separate floating window
DLHELPlist every quick tool and drive shortcut on the command line
DLLOGOUTsign out of the palette
DLABOUT · DLDIAG · DLCHECKversion · diagnostics for support · self-test (section 6)

4Sign in, credits and plans

The plugin is free: placing, circuiting, piping, tagging and every drawing it puts in your CAD file cost nothing. Only the design reports and the Excel files need a design credit or a plan.

1

Click Sign in in the top bar of the palette. Type your DesignLink e-mail and password and click Sign in. The first sign-in gives one design free.

Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
2

A 6-digit code is e-mailed to you (it is valid for 10 minutes). Type it and click Sign in. Accounts with an authenticator app are asked for the authenticator code instead. The palette remembers the sign-in for 30 days.

Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
3

The first time only, read the short disclaimer, tick the box and click I agree — continue.

Action in the pluginNeeds
Open the palette, select rooms, place lights / sockets / devices, switch boards, DB, circuit & loop, tag & zone, quantities on screennothing — free
Your own symbols and layer names saved for next time; your project list in Place a drawingsign-in
Details & legend sheets, schematics, piping / loops drawings, Place a drawing, sewer plan & L-sections — drawn in CADnothing — free
Design reports (calculations, checks, BOQ), Schedules Excel, CPWD DSR BOQ Excela design credit or a plan
One design credit unlocks one project for 30 days — every output, re-run and re-download. Company users of a registered DesignLink company and Unlimited plans have everything included. When a report or Excel needs a credit the palette shows Get this design: sign in for the free design, buy one, or buy a pack.

5Drive mode and the expert view

Daily work has two faces. Drive mode shows one decision per screen with big buttons and nothing to scroll — this is what the guide uses. The expert view shows every button at once (section 30).

1

Type DLD (or choose Drive mode in the tool menu). The home screen asks What do you want to place? — 18 design tools on top, then CPWD DSR BOQ, Quick tools, Change & number, Cable tray control, Loop optimiser, Quantities, DIALux and Setup.

What do you want to place?
What do you want to place?

Every screen has the same header: the back arrow (left) goes one step back, the title says what to do now, the small line above it shows the step and the tool. When the drawing has more than one floor, an orange floor button shows the current floor — click it to switch. The dashboard icon (right) opens the expert view; the Drive button there comes back.

ShortcutOpensShortcutOpens
DLLLightingDLHVHVAC ducts & units
DLPPower pointsDLCPCar-park ventilation
DLFFire alarm devicesDLEALightning & earthing
DLFLFire alarm loopsDLGSGas suppression
DLSSprinklersDLELELV cabling & racks
DLWWiring & loopingDLHFHVLS fans
DLTCable tray & feedersDLE / DLN / DLUChange what was placed / Numbering / Undo
DLTOToilet plumbingDLCT / DLLOCable tray control / Loop optimiser
DLQTQuick toolsDLQ / DLDXQuantities / DIALux
DLSETSetupDLAXBuilding direction

6First time in a drawing: Setup

Two minutes of setup per drawing makes every tool right first time: the drawing units, the floors, your office layer names and your own blocks.

1

Type DLSET (or Drive home → Setup). Six tiles: Units & scale, Floors, Layer names, Building direction, My blocks and Check this CAD.

Setup
Setup
2

Units & scale — the palette reads the drawing units and shows how wide the plan comes out with each unit (“plan 60.0 m wide”). Click the unit that gives the real building size (a door ≈ 0.9 m), then the plot scale (1:50 / 1:100 / 1:200) — text heights of everything drawn follow it.

Units of this drawing
Units of this drawing
3

Floors — one drawing can hold several floors. Add a floor asks the name and level; Area of GF lets you window round that floor’s plan so rooms picked inside it go to that floor automatically; Rename renames the current floor.

Floors in this drawing
Floors in this drawing
4

Layer names — type your office layer for each DesignLink layer (blank keeps the DesignLink name) and click Save my layer names. Used for everything drawn from now on, in every drawing (sign-in needed to keep them).

Layer names
Layer names
5

My blocks — Pick a block for a symbol: choose a DesignLink symbol, then click your own block in the drawing. From then on every tool places your block (TAG / CKT go into its attributes when it has them). Preview switches the cyan ghost preview on or off.

My blocks
My blocks
6

Building direction — rows of lights, loops and routes follow the building. Pick a wall / grid line (most buildings), From the UCS, Square to the sheet (0°) or Type an angle.

Building direction — now 0.0°
Building direction — now 0.0°
7

Check this CAD runs DLCHECK: click an empty spot, the plugin tries every drawing operation on a scratch layer, removes the test objects and prints PASS / FAIL lines — send that text to support when something does not work.

In the drawing — command line
> Click an empty spot for the test objects (they are removed again):
Setup
Setup

7Selecting rooms — the same in every tool

Every tool that works on rooms shows the same picker with the same tiles in the same order.

1

How do you want to select the room? — pick one way:
Click inside room click inside each room, Enter when done · Rectangle (2 corners) · Polygon (corners) click every corner, click the first again to close · Pick room polyline closed polylines, also inside an xref · All polylines on a layer pick one room polyline and every closed polyline on its layer becomes a room · Window select window over room polylines · Whole floor (walls + glass) every room of the floor from the wall layers.

In the drawing — command line
> Click inside a room — Enter to finish:
> First corner of the room: / Opposite corner:
> Next corner — click the first corner, C or Enter to close, U to undo:
How do you want to select the room?
How do you want to select the room?
2

The first time you use Click inside room, the palette asks Tell me the wall layer (once). Click Click a wall line and click any wall in the drawing: rooms are then found from the walls only, with door gaps closed. Skip uses the CAD boundary trace instead (door openings may leak).

Tell me the wall layer (once)
Tell me the wall layer (once)
3

Now work in the drawing — the palette waits while you click. Click inside as many rooms as you like and press Enter. Room names come from the texts inside each room.

In the drawing — command line
> Click inside a room (2 selected) — Enter to finish:
Now work in the drawing
Now work in the drawing
4

Whole floor asks three layers, one click each: the wall layer, the glass / window layer (No glass layer if none) and a room-name text (Skip names if none). Every closed room of the floor is found at once.

In the drawing — command line
> Click a wall line
> Click a glass / window line
> Click a room-name text
Whole floor — walls
Whole floor — walls
Walls inside an xref or a block are read too (plugin 1.8). If a room will not close, use Rectangle, Polygon or Pick polyline for that room.

8Lighting

Luminaires for the required lux of every room — code lux per room type, layout on the grid, preview, then placed as blocks with the lux written back.

1

Drive home → Lighting (or DLL). Check the settings: ceiling height, code (Indian NBC / IS / CPWD or International IEC / EN) and the luminaire from the library. Click Confirm.

Check the settings
Check the settings
2

Select the room(s) — any tile of the room picker (section 7).

How do you want to select the room?
How do you want to select the room?
3

Required lux & rotation — rooms are grouped by type with the code value filled in (NBC 2016 / IS 3646, or EN 12464-1). Change the room type or type a different lux to override. Choose the rotation: Auto (best spacing), 0°, 90° or Angle. Click Place luminaires.

Required lux & rotation
Required lux & rotation
4

Check the preview — the layout shows in cyan in the drawing; nothing is drawn yet. Place them, Change (back one step) or Place — no more previews.

Check the preview
Check the preview
5

Done ✔ — per room: number of luminaires, average lux against the target, ✔ or ⚠. Next: Next room(s) with the same settings, Wiring & looping, Change settings, Another tool, Change / undo or Finish.

Done ✔
Done ✔

9Power points

Sockets by room type for the socket standard of the country, snapped to the walls.

1

Drive home → Power points (DLP). Settings: ceiling height, code and Socket type — India (6 / 16 A), UK (13 A), EU / Gulf or US (NEMA). Confirm.

Check the settings
Check the settings
2

Select the room(s).

How do you want to select the room?
How do you want to select the room?
3

Check the preview — the points in cyan along the walls. Place them.

Check the preview
Check the preview
4

Done ✔ — points per room. Move or delete any in the drawing; the wiring reads them as they are. Continue with Wiring & looping.

Done ✔
Done ✔

10Wiring & looping

From the DB to every switch board, the looping of every point, conduit sizes, circuits and the DB schedule — drawn as dashed curves with the home runs labelled.

1

Drive home → Wiring & looping (DLW), or from the Lighting / Power Done screen. Settings: Conduit (MS medium class or PVC heavy duty) and Installation (concealed in RCC slab and wall chases, surface on RCC, or industrial shed). Confirm.

Check the settings
Check the settings
2

Where is the DB? — Click the DB position and click the wall, or Keep the DB placed before. No DB yet assumes the floor centre.

In the drawing — command line
> Click the DB position (wall)
Where is the DB?
Where is the DB?
3

Switch boards — the screen says how many rooms with points have no board. Click each board (one click per room, Esc skips a room), Place them for me (on the wall towards the DB) or Loop without boards (those rooms get a TO DB arrow).

In the drawing — command line
> <room>: switch board position — Esc to skip
Switch boards
Switch boards
4

When every room has its board the third tile reads Loop now. Move any board in the drawing first if you like — its new position is read back.

Switch boards
Switch boards
5

Wiring done ✔ — circuits, loops, home runs, conduit sizes and the DB summary. Details & legend places the typical details and the legend with this floor’s quantities. Loop again after moving boards or points — the old looping is replaced.

Wiring done ✔
Wiring done ✔

11Fire alarm devices

Smoke / heat detectors, call points and sounders in the selected rooms by the code spacing.

1

Drive home → Fire alarm (DLF). Settings: ceiling height and code. Confirm.

Check the settings
Check the settings
2

Select the room(s).

How do you want to select the room?
How do you want to select the room?
3

Done ✔ — devices per room. Next: Loops, zones & schematic (section 12).

Done ✔
Done ✔

12Fire alarm loops, zones and schematic

Zones, loop addressing, isolators and cable routes for the devices placed by DesignLink or for the drawing’s own blocks — then the schematic and typical details.

1

Drive home → Fire alarm loops (DLFL). Settings: System (addressable loops or conventional zones), Loop wiring (Class A back to the panel, Class B open), Devices per loop (panel capacity, 125) and the zone / loop number to start at. Confirm.

Check the settings
Check the settings
2

Which fire alarm devices? — Devices placed by DesignLink or Blocks already in the drawing.

Which fire alarm devices?
Which fire alarm devices?
3

For your own blocks, one screen per kind: Click a smoke detector block and click one in the drawing — every copy is taken. Then heat detector, multi-sensor, call point, sounder, strobe and interface module: click one, Keep the last one used, or None in this drawing.

In the drawing — command line
> Click a smoke detector block
Click a smoke detector
Click a smoke detector
4

Which part of the drawing? — Whole drawing or A window (2 corners) for one floor / wing.

Which part of the drawing?
Which part of the drawing?
5

Where is the fire alarm panel? — Click the panel position (FACP on the wall) or Not on this floor (the loop starts at the riser).

In the drawing — command line
> Click the fire alarm panel position
Where is the fire alarm panel?
Where is the fire alarm panel?
6

Fire alarm ✔ — zones with areas, loops with addresses and lengths, cable, isolators. Addresses go into the blocks’ TAG attribute (or as text beside them). Schematic + legend and Typical details place sheets at a picked corner. The next floor continues the zone and loop numbers.

Fire alarm ✔
Fire alarm ✔

13CCTV, Data / Tel, PA speakers, Wi-Fi

The same three screens for each ELV system: settings → rooms → done.

1

Drive home → CCTV, Data / Tel, PA speakers or Wi-Fi. Check the ceiling height and code, Confirm.

Check the settings
Check the settings
2

Select the room(s).

How do you want to select the room?
How do you want to select the room?
3

Done ✔ — devices per room. Cabling to racks, PoE and rack elevations: ELV cabling & racks (section 16). Tags and zones for a whole floor: expert view → ELV → Tag & zone this floor.

Done ✔
Done ✔
Done ✔
Done ✔
Done ✔
Done ✔
Done ✔
Done ✔

14Sprinklers

Heads by hazard and room use → move or add by hand → pipe every head (range, cross and main pipes sized, remote-area check) → details and legend.

1

Drive home → Sprinklers (DLS). Settings (also: pipe drawing single line or double line at true OD with fittings and joint marks, false-ceiling void for the drops, beam clearance, the IS 15105 design area and 32 mm room feed): hazard where the room use is not known, head type (pendent, upright, up + down for false ceilings, concealed, sidewall), temperature rating, pipe joints (threaded / welded / grooved) and supports (rigid or wire rope, RCC or shed). Confirm.

Check the settings
Check the settings
2

Sprinkler symbols — the DesignLink symbol, or click a tile and pick your own head block in the drawing. Continue — select rooms.

In the drawing — command line
> Click your upright sprinkler block in the drawing
Sprinkler symbols
Sprinkler symbols
3

Select the rooms, then Rooms by use: hazard, head type and temperature are suggested from the room names (kitchen 93 °C, boiler 141 °C, parking and stores OH …). Change any value and click Place sprinklers.

Rooms by use
Rooms by use
4

Beams — Click a beam line (every line on that layer is a beam edge), Keep the layer from last time, or No beams / flat slab. Uprights — and the upright of every up + down pair — keep the clearance set in the settings (0.45 m by default) from every beam; the pendent stays on the grid. An up + down pair is drawn as two symbols: the pendent, and the upright 0.75 m above it — move the upright freely; up to 1.5 m away it still counts as the same pair.

In the drawing — command line
> Click a beam line
5

Sprinklers — heads per room with the spacing. Move, copy or delete heads in the drawing as you like. Add heads by hand (one per click, Esc ends) or More rooms.

Sprinklers
Sprinklers
6

Pipe all heads → Where is the sprinkler riser? — Click the riser point (floor control valve), Same riser as before or Let the tool choose.

In the drawing — command line
> Click the sprinkler riser / floor control valve
Where is the sprinkler riser?
Where is the sprinkler riser?
7

Main header route — Draw the main route (click along the corridor, Enter; then draw branches, Enter on an empty line when done), Pick polyline(s) already drawn, Same route as before or Let the tool route it (corridors by name, else the shortest path from the riser). Rooms are fed by square drops from the main.

In the drawing — command line
> Main route: first point at the riser end
8

Every head on the sprinkler layer is piped: zones, pipe metres per size, remote-area flow and pressure, fittings and hangers, checks. Moved heads? Pipe all heads again — the old piping is replaced. Details & legend places installation details with the quantities.

Sprinklers
Sprinklers

15Toilet plumbing

From the fixture blocks already in the drawing: soil, waste, vent, cold, flushing, hot and RO pipes to the shaft, sized and drawn, with wall elevations, details and legend.

1

Drive home → Toilet plumbing (DLTO). Settings: drainage (two-pipe or single stack; uPVC SWR, cast iron, HDPE), water pipes · flushing (CPVC / PPR / GI / copper; cistern or flush valves), systems, fixtures per trap, drawings (a sheet per system or in place; geysers or central hot water). Confirm.

Check the settings
Check the settings
2

One screen per fixture: Click a WC — click one WC block in the drawing; every copy becomes a fixture. Then wash basin, urinal, shower, bath tub, sink, floor trap and ablution tap (None in these toilets when absent).

In the drawing — command line
> Click a WC block
> Click a wash basin block
Click a WC
Click a WC
3

Which toilets? — Window around the toilets or Whole drawing.

Which toilets?
Which toilets?
4

Plumbing shaft — Draw the shaft (2 corners); add more shafts if needed, then Continue.

In the drawing — command line
> First corner of the room:
> Opposite corner:
Plumbing shaft
Plumbing shaft
5

Toilet rooms (optional) — pick the toilet rooms, or Skip (walls are found from the fixtures).

Toilet rooms (optional)
Toilet rooms (optional)
6

Settings → Pipe drawing: P-line at true OD + fittings (default) draws every pipe at its outside diameter with bends, wyes / tees and reducers — the drainage as it is laid: WCs, basins and urinals on 45° branches into a main set back from the wall, 45° bend pairs, invert levels (IL) at every branch and '100 Ø UP TO WC' at every outlet; Double line or Single line as alternatives. Sunken slab depth is checked against the invert levels.

7

Isometrics places the drainage isometric (soil / waste / vent with sizes and IL) and the water-supply isometric (CW / flushing / HW / RO with header and outlet heights) at a picked corner. The detail sheets now include the shaft plan with this project's stacks and risers.

8

Toilets ✔ — fixtures, shaft groups, systems, pipe sizes and fittings. Elevations, details & legend places the wall elevations and details. Draw again after moving fixtures or the shaft.

Toilets ✔
Toilets ✔

16ELV cabling & racks

Cameras, data outlets, access points and readers cabled to the racks along the tray: channel lengths checked, PoE budget, switch and patch-panel count, rack elevations and the schematic.

1

Drive home → ELV cabling & racks (DLEL). Check the settings — cable, containment, max channel length, PoE budget basis, spare ports, patch panel size, switch type. Confirm.

Check the settings
Check the settings
2

Pick the ELV devices — Devices placed by DesignLink or Blocks already in the drawing (click one camera, outlet, AP, reader …; every copy is read).

Pick the ELV devices (cameras, outlets, APs, readers)
Pick the ELV devices (cameras, outlets, APs, readers)
3

Click each rack (floor IDF / server rack), Enter when done, then Continue.

In the drawing — command line
> Rack position
Click each rack (floor IDF / server rack)
Click each rack (floor IDF / server rack)
4

Draw / pick the cable tray route(s) — Pick a polyline / line or Click the points (Enter ends); add more routes, then Continue.

In the drawing — command line
> Tray route (pick a polyline or click points, Enter ends)
Draw / pick the cable tray route(s)
Draw / pick the cable tray route(s)
5

Check the preview in cyan → Place them.

Check the preview
Check the preview
6

ELV cabling & racks ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

ELV cabling & racks ✔
ELV cabling & racks ✔

17Lightning & earthing

Air termination on the roof (mesh / rods), down conductors, ring earth and pits by LPS class, equipment earthing with strip sizes from the fault level.

1

Drive home → Lightning & earthing (DLEA). Check the settings — LPS class, air termination, roof, conductor, earth electrode, soil resistivity, target earth resistance, fault level for the earth strips. Confirm.

Check the settings
Check the settings
2

Draw the roof outline — click inside, two corners, every corner or pick the roof polyline.

Draw the roof outline (click every corner)
Draw the roof outline (click every corner)
3

Building height (m) → Continue.

Building height
Building height
4

Click roof equipment / parapet corners to protect (Enter when done), or Skip.

In the drawing — command line
> Roof equipment / corner
Click roof equipment / parapet corners to protect
Click roof equipment / parapet corners to protect
5

Equipment to earth — transformer, DG, LT panel, lift, UPS … blocks in the drawing, or Skip.

Equipment to earth (transformer, DG, LT panel, lift, UPS …)
Equipment to earth (transformer, DG, LT panel, lift, UPS …)
6

Earth pit zone (optional) — Two corners or Skip (pits around the building).

Earth pit zone (optional — default: around the building)
Earth pit zone (optional — default: around the building)
7

Check the preview in cyan → Place them.

Check the preview
Check the preview
8

Lightning & earthing ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

Lightning & earthing ✔
Lightning & earthing ✔

18Gas suppression

FM-200, Novec 1230 or IG-541: agent quantity for the room volume (with void depths), nozzles, piping, cylinder bank, cross-zoned detectors and pressure relief.

1

Drive home → Gas suppression (DLGS). Check the settings — agent, hazard class, design concentration, minimum room temperature, site altitude, protect, cylinder size, reserve, several rooms, enclosure strength. Confirm.

Check the settings
Check the settings
2

Select the room(s) to protect — the room picker.

Select the room(s) to protect
Select the room(s) to protect
3

Room height (slab to slab or ceiling) → Continue.

Room height (slab to slab or ceiling)
Room height (slab to slab or ceiling)
4

False ceiling / raised floor void depths, e.g. 0.6, 0.45 → Continue or Skip.

False ceiling / raised floor void depths (e.g. 0.6, 0.45)
False ceiling / raised floor void depths (e.g. 0.6, 0.45)
5

Click the cylinder bank position.

In the drawing — command line
> Cylinder bank position
Click the cylinder bank position
Click the cylinder bank position
6

Existing smoke / heat detectors in the rooms, or Skip for new cross-zoned detectors.

Existing smoke / heat detectors in the rooms (Skip = new cross-zoned detectors)
Existing smoke / heat detectors in the rooms (Skip = new cross-zoned detectors)
7

Check the preview in cyan → Place them.

Check the preview
Check the preview
8

Gas suppression ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

Gas suppression ✔
Gas suppression ✔

19Car-park ventilation

Jet fans for the normal and fire / smoke rates, exhaust and supply shafts, CO sensors and smoke zones for the car-park outline.

1

Drive home → Car-park ventilation (DLCP). Check the settings — normal ventilation rate, fire / smoke mode rate, jet fan thrust and type, CO sensor coverage, smoke zone max area, supply air as % of exhaust, clear height. Confirm.

Check the settings
Check the settings
2

Draw the car-park outline (click every corner, two corners or pick the polyline).

Draw the car-park outline (click every corner)
Draw the car-park outline (click every corner)
3

Clear height → Continue.

Clear height
Clear height
4

Click the ramp / entry openings (fresh air), Enter when done → Continue.

In the drawing — command line
> Ramp / entry opening
Click the ramp / entry openings (fresh air)
Click the ramp / entry openings (fresh air)
5

Click the exhaust shaft position(s) → Continue.

In the drawing — command line
> Exhaust shaft
Click the exhaust shaft position(s)
Click the exhaust shaft position(s)
6

Click the fresh-air (supply) shaft position(s) → Continue or Skip.

In the drawing — command line
> Supply shaft
Click the fresh-air (supply) shaft position(s)
Click the fresh-air (supply) shaft position(s)
7

Pick / draw big beams or walls that block the airflow → Continue or Skip.

In the drawing — command line
> Beam / wall
Pick / draw big beams or walls that block the airflow
Pick / draw big beams or walls that block the airflow
8

Check the preview in cyan → Place them.

Check the preview
Check the preview
9

Car-park ventilation ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

Car-park ventilation ✔
Car-park ventilation ✔

20HVAC ducts & units

Diffusers per room from the heat load, duct routing along the corridor and sizing, or VRF / FCU units with refrigerant and drain piping.

1

Drive home → HVAC ducts & units (DLHV). Check the settings — system, load basis, duct sizing, diffuser type, max throw, duct material, duct insulation, refrigerant pipe. Confirm.

Check the settings
Check the settings
2

Select the air-conditioned rooms — the room picker.

Select the air-conditioned rooms
Select the air-conditioned rooms
3

Heat-load project code (optional, from the Heat load tool) → Continue or Skip.

Heat-load project code (optional)
Heat-load project code (optional)
4

Click the AHU / FCU / outdoor unit position.

In the drawing — command line
> Unit position (AHU / CHW riser / outdoor units)
Click the AHU / FCU / outdoor unit position
Click the AHU / FCU / outdoor unit position
5

Draw / pick the main duct or pipe route along the corridor — polyline or points.

In the drawing — command line
> Route along the corridor (Enter ends)
Draw / pick the main duct or pipe route (corridor)
Draw / pick the main duct or pipe route (corridor)
6

Pick existing indoor units, diffusers and return grilles, or Skip to lay them out.

Pick existing indoor units, diffusers and return grilles
Pick existing indoor units, diffusers and return grilles
7

Check the preview in cyan → Place them.

Check the preview
Check the preview
8

HVAC ducts & units ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

HVAC ducts & units ✔
HVAC ducts & units ✔

21Cable tray & feeders

LT feeders routed on the tray: fill, tray size, tiers and segregation, sections and the cable schedule — feeders from a voltage-drop project or typed.

1

Drive home → Cable tray & feeders (DLT). Check the settings — tray type, material, fill basis, max tray width, tiers allowed, segregation, support spacing, feeders from, cable route lines on the plan. Confirm.

Check the settings
Check the settings
2

Draw / pick the cable tray route(s) → Continue.

In the drawing — command line
> Tray route (pick a polyline or click points)
Draw / pick the cable tray route(s)
Draw / pick the cable tray route(s)
3

Panels and DBs on this floor — click one panel / DB block (its TAG attribute is the name); every copy is read.

In the drawing — command line
> Click a LT panel / DB block (TAG attribute = name) block
Click a LT panel / DB block (TAG attribute = name)
Click a LT panel / DB block (TAG attribute = name)
4

Voltage-drop project code (feeders from the VD tool) → Continue or Skip.

Voltage-drop project code (feeders)
Voltage-drop project code (feeders)
5

Or type feeders, one per line: MLTP > LDB-1 : 4C x 25 Sq.mm, Al → Continue.

Or type feeders: FROM > TO : cable, one per line
Or type feeders: FROM > TO : cable, one per line
6

Click the main LT panel if it is not a block, or Skip.

In the drawing — command line
> Main LT panel position
Click the main LT panel if it is not a block
Click the main LT panel if it is not a block
7

Check the preview in cyan → Place them.

Check the preview
Check the preview
8

Cable tray & feeders ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

Cable tray & feeders ✔
Cable tray & feeders ✔

22HVLS fans

Fan count and layout for the area and its racks, with the air-speed map at the occupied plane.

1

Drive home → HVLS fans (DLHF). Check the settings — fan size, target air speed at the plane, target coverage, occupied plane height. Confirm.

Check the settings
Check the settings
2

Draw the area outline (click every corner, two corners or pick the polyline).

Draw the area outline (click every corner)
Draw the area outline (click every corner)
3

Clear height to the underside of the roof structure → Continue.

Clear height to the underside of the roof structure
Clear height to the underside of the roof structure
4

Pick the racks / equipment outlines (closed polylines) or walls → Continue or Skip.

In the drawing — command line
> Rack / obstruction outline
Pick the racks / equipment outlines (closed polylines) or walls
Pick the racks / equipment outlines (closed polylines) or walls
5

Height of the racks / obstructions → Continue.

Height of the racks / obstructions
Height of the racks / obstructions
6

Existing HVLS fan blocks, or Skip to lay the fans out automatically.

Existing HVLS fan blocks (skip to lay the fans out automatically)
Existing HVLS fan blocks (skip to lay the fans out automatically)
7

Check the preview in cyan → Place them.

Check the preview
Check the preview
8

HVLS fans ✔ — the summary of what was designed and drawn. Schematic, legend & schedules and Typical details place their sheets at a picked corner. Run again keeps your picks after you move things; Pick again starts the steps over.

HVLS fans ✔
HVLS fans ✔

23Change what was placed

Edit after placing without starting over: every DesignLink block keeps its link to the design.

1

Type DLE (or Drive home → Change & number, or Change / undo on any Done screen). Thirteen tools:

Change what was placed
Change what was placed
2

Re-read & re-route — after moving, copying or deleting blocks by hand: the record is matched to the drawing (moved / copied / deleted counts) and the screen offers to re-route what depends on it: Loop again, fire alarm loops, sprinkler piping, or the last tool.

Drawing read
Drawing read
3

Re-array a room — the room changed size: pick the room as it is now and its devices are laid out again.

Pick the room as it is now
Pick the room as it is now
4

Align devices — window over devices, then One row (same Y), One column (same X), Rows & columns (snap to the nearest row / column) or Equal spacing (ends stay).

In the drawing — command line
> Select the blocks to line up
Line them up how?
Line them up how?
5

Replace symbol — window over DesignLink devices, pick the new symbol: same place and angle. For any other block use DLBRE.

In the drawing — command line
> Select the devices whose symbol changes
Select the devices
Select the devices
6

Outlets along a wall — sockets, switches, data / tel / TV or other wall devices along a wall you pick, at the spacing you type.

In the drawing — command line
> First end of the wall
> Other end of the wall
> Click inside the room (which side of the wall)
Which kind of outlet?
Which kind of outlet?
7

Connect blocks — Two blocks square route around other blocks, Two blocks — I shape it (the route follows the mouse), Chain several (first → … → last: data, PA …) or straight.

Connect how?
Connect how?
8

Junction boxes (after looping) — boxes at the loop branch points, previewed first. Home runs — DB → each circuit with a gap between parallel runs.

Check the preview
Check the preview
9

Undo last run — removes what the last run drew and brings back what it erased; changes you made by hand afterwards stay. DLU opens it directly.

Undo the last run?
Undo the last run?

24Numbering

Tags in the order you want, written into the blocks.

1

Type DLN. Set the prefix, start, step and the attribute (TAG, CKT …). Then the order: Click order (one click per device), Rows, left → right, Snake (alternate rows), Columns, top → bottom or Along the path (nearest next). Fix a run renumbers part of a run; Phase colours colours loops R / Y / B.

In the drawing — command line
> Select the devices to number
Number the devices
Number the devices

25Cable tray control

Draw and edit cable trays as real trays: width, type, fittings with radius, supports and the tray Q.S.

1

Type DLCT (or Drive home → Cable tray control). Choose the default width, depth and type (ladder, perforated, …) at the bottom, and tick Draw supports, Hatch, Covers. Draw from polylines turns centre-lines into trays; Add section draws by points (a branch when it starts on a tray).

In the drawing — command line
> Select the polylines / lines along the tray centre
> Next point of the tray section (Enter to finish)
Cable tray control
Cable tray control
2

Once a tray exists: Move section (2 points), Change width, Remove section, Add reducer, Change tray type, Join / extend, Undo change; Tray Q.S places the quantity table and sends the BOQ lines.

Cable tray control
Cable tray control
3

Fitting radius — inner radius of bends (mm) → Apply. Supports — support span (mm) → Apply.

Fitting radius
Fitting radius

26Loop optimiser

The shortest fire-alarm (or any) loops round the columns and shafts, with addresses written into the blocks.

1

Type DLLO. 1 · Loop devices — Select window over the devices (or FA takes the fire alarm devices placed); switch block names on / off with the chips. 2 · Panel — Click the panel. 3 · Avoid — Select the column / shaft blocks. Set the direction, Class A / B, devices per loop and the effort (Fast / Better / Best), tick Write addresses, then Run.

In the drawing — command line
> Select the loop devices
> Click the panel (start of the loops)
> Select the structure blocks (columns, shafts)
Loops — optimise
Loops — optimise
2

Preview in cyan → Place them. Loops ✔ shows each loop’s devices and length and the metres saved against the next-nearest order. Run again after moving devices — the old loops are replaced.

27Quantities

Counts and lengths straight from the drawing — as a table in the drawing or into the CPWD DSR BOQ.

1

Type DLQ. What do you want to count? — Count blocks by name, Blocks by layer, By attribute (TAG, CKT, any tag), Dynamic states (visibility state), Length by layer (lines, polylines, arcs), Average point length (ceiling / wall points from the looping), Tray Q.S and Open the DSR BOQ.

What do you want to count?
What do you want to count?
2

Which part of the drawing? — Whole drawing, A window or Inside a polyline (a room, a floor, a zone). Blocks inside xrefs are counted too.

Which part of the drawing?
Which part of the drawing?
3

The result table shows on screen. Then place it as a table in the drawing (click the top-left corner) or send it to the DSR BOQ — sending the same kind again replaces it.

In the drawing — command line
> Top-left corner of the quantity table

28DIALux

Rooms and luminaires to DIALux evo, and a DIALux layout back into DesignLink.

1

Type DLDX. Export to DIALux (.stf) — every room with its outline, height and luminaires as an STF file to open in DIALux evo. Import a DIALux evo layout — click one luminaire block of the DIALux plan, choose the part of the drawing, tell which DesignLink luminaire it is, then Replace with my symbol or Keep the DIALux blocks.

In the drawing — command line
> Click one luminaire block of the DIALux plan
DIALux
DIALux

29CPWD DSR BOQ

Everything placed and counted, priced on CPWD DSR in the 5-sheet BOQ (Summary, BOQ, Take Off, Rate Analysis DSR and Non-DSR).

1

Drive home → CPWD DSR BOQ (or expert view → Schematics → CPWD DSR BOQ). With several drawings open: Include all open drawings? — All open drawings (one BOQ, a Take Off per drawing / floor) or Only this drawing. A drawing without a DesignLink session is marked — open Daily work in it once.

Include all open drawings? (3 open: GF-ELECTRICAL.dwg, FF-ELECTRICAL.dwg, SF-ELECTRICAL.dwg)
Include all open drawings? (3 open: GF-ELECTRICAL.dwg, FF-ELECTRICAL.dwg, SF-ELECTRICAL.dwg)
2

The DSR BOQ page opens in the palette with the items, quantities and rates; download the Excel (needs a credit).

30The expert view (all buttons)

The same engine as Drive mode, every button on one page — for quick single actions.

1

In Drive mode click the dashboard icon (top right). The top bar: floor list and + (add a floor), ceiling height, socket regime (India / UK / EU / Gulf / US), codes (Indian / International), Drive (back to drive mode), sign-in. Tabs: Lighting · Power · ELV · Schematics.

Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
2

The room card: the selection chips start the command at once — Click inside, Rectangle, Polygon, Pick polyline, Same layer, Window; the big button repeats it. The card shows the room name, type, lux, ceiling and devices. Add ceiling zone, Ceiling grid…, Symbols… (your own blocks) and Clear room.

In the drawing — command line
> Click inside a room (1 selected) — Enter to finish:
Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
3

Lighting — search and click a luminaire, choose the rotation, then Auto place for the room’s lux (result: count, W, LPD, Ē, Uo, emergency) or Place one per click (lux updates after every click). With several rooms: Auto place in all selected rooms.

In the drawing — command line
> Place <luminaire> — Esc to stop
Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
4

Power — choose a point type (fan, sockets by regime, AC point, isolator, industrial, floor box), then Place by click (wall-snapped) or Auto for this room.

In the drawing — command line
> Place 6 A socket (India) — Esc to stop
Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
5

Switchboard & circuits — Place switchboard (click the wall), Place / move DB, then Circuit & loop this floor: the circuit table (Ckt · Kind · Pts · W · MCB · mm² · Ph · Rooms) and the looping drawn. Details & legend places the detail sheet.

In the drawing — command line
> Click the wall for the switchboard — Esc to cancel
> Click the DB position (wall)
Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
6

ELV — system chips (fire alarm, PA, CCTV, data, telephone, MATV, Wi-Fi, access control) and their devices; Place by click, Auto for this room, Auto for all rooms and Tag & zone this floor.

Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc
7

Schematics — the floor summary and the BOQ table. Choose a system, then Schematic into drawing, Schematic DXF, Schedules Excel or CPWD DSR BOQ (the Excel files need a credit).

In the drawing — command line
> Insertion point for the DesignLink drawing:
Daily work — lighting, power, ELV in the drawing — designlink calc
Daily work — lighting, power, ELV in the drawing — designlink calc

31Quick tools

57 drafting tools for everyday CAD work — selection, blocks, attributes, lines, dimensions, text, plotting and xrefs. Click a tile and answer in the drawing, or type the command.

1

Type DLQT (or Drive home → Quick tools). Tabs on top: Select · Blocks · Block+ · Attrib · Lines · Dims · Text · Plot. Each tile shows its command name (e.g. DLSSB) — click it, then answer on the command line. Typed commands work without the palette; DLHELP lists them all.

Quick tools
Quick tools

Select

Quick tools → Select
Quick tools → Select
Tile · commandWhat it doesCommand line, in order
Similar
DLSS
Select every object like the picked one: same type + layer + colour (and same block name for blocks).
> Select an object:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:
Same layer
DLSSL
Select every object on the same layer as the picked one.
> Select an object:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:
Same colour
DLSSC
Select every object with the same colour as the picked one.
> Select an object:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:
Same block
DLSSB
Select every block with the same name as the picked block.
> Select a block:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:
Attribute value
DLSSA
Select all blocks carrying the same attribute (tag + value, or tag only).
> Click the attribute text inside a block:
> Match <TAG> [Value/Tag] (value = "<value>") <Value>:
Blocks in polyline
DLSSP
Select the blocks with the same name that lie inside a closed polyline / circle.
> Select a block:
> Select the closed polyline / circle around the area:
Visibility state
DLSSV
Select blocks with the same name and the same dynamic visibility state.
> Select a block:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:
By properties
DLSSO
Select objects matching the picked one on a chosen set of properties.
> Match which properties — letters T type, L layer, C colour, Y linetype, B block, W lineweight, X text <TL>:
> Select an object:
> Where [All/Window/Polyline] <All>:
> [Window] Select the area (window):
> [Polyline] Select the closed polyline / circle around the area:

Blocks

Quick tools → Blocks
Quick tools → Blocks
Tile · commandWhat it doesCommand line, in order
Replace blocks
DLBRE
Replace selected blocks by another block, keeping position, angle, scale, layer and attribute values.
> Select the blocks to replace:
> Replacement block [Pick/Name] <Pick>:
> [Pick] Select the replacement block:
> [Name] Block name:
> Scale [Keep/One] <Keep>:
Replace in drawings
DLBRB
Replace a block in other (closed) drawings by a block from this drawing.
> New block (from this drawing) [Pick/Name] <Pick>:
> [Pick] Select the new block (from this drawing):
> [Name] Block name:
> Block to replace in the other drawings <<new block name>>:
> File dialog 'Drawings where <target> becomes <new>' (Drawings (*.dwg), multi-select)
Rename all
DLRBB
Rename a block definition (every copy in the drawing).
> Select the block to rename (every copy in the drawing):
> New name for <old>:
Rename these
DLRB
Give only the selected copies of a block a new name (the others keep the old one).
> Select the block copies to give a new name (others keep the old one):
> New name for the selected <old> <<old>_A>:
Duplicate
DLDB
Duplicate a block definition under a new name.
> Select the block to duplicate:
> Name of the copy <<name>_COPY>:
> Switch the picked block to the copy [Yes/No] <No>:
Quick block
DLQB
Quick block: turn selected objects into a block in one go.
> Select the objects for the new block:
> Block name <QB_HHmmss>:
> Base point:
Base point
DLCBPR
Change a block's base point without moving any copy in the drawing.
> Select the block:
> New base point:
Default rotation
DLROT0
Make a block's present rotation its normal 0° rotation.
> Select a block whose present rotation should become its normal (0°) rotation:
Default scale
DLSC0
Make a block's present scale its scale 1.
> Select a block whose present scale should become its scale 1:
Rotate many
DLROTM
Rotate many blocks, each about its own base point (add an angle or set an absolute angle).
> Select the blocks to rotate (each about its own base point):
> Angle [Add/Set] <Add>:
> [Add] Rotate by (degrees, + = anticlockwise): (number; default 90; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it)
> [Set] Set every block to (degrees): (number; default 90; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it)
> Keep attribute text readable [Yes/No] <Yes>:
Rescale many
DLRESB
Rescale many blocks, each about its own base point.
> Select the blocks to rescale (each about its own base point):
> Factor (1.5 = 50 % bigger): (number; default 1.5; must be > 0; the CAD shows the default as <…>, Enter accepts it)
Dynamic → static
DLD2R
Convert dynamic blocks to static blocks (one static block per dynamic block + visibility state).
> Select the dynamic blocks to make static:

Block+

Quick tools → Block+
Quick tools → Block+
Tile · commandWhat it doesCommand line, in order
Add to block
DLADD2B
Add objects to a block definition without the block editor (every copy changes).
> Select the objects to add to a block:
> Select the block to add them to:
> Keep the originals in the drawing [Yes/No] <No>:
Remove from block
DLREMB
Remove objects from a block definition by clicking them inside a block (repeats).
> Leave a copy of each removed object in the drawing [Yes/No] <No>:
> Click an object inside a block to remove it (Enter to finish):
Trim lines in blocks
DLABBM
Cut the lines/polylines/arcs that run through blocks at the block outline.
> Select the blocks (lines running through them are cut at their outline):
> Extra gap around each block: (number; default 0; zero allowed; the CAD shows the default as <…>, Enter accepts it)
Restore exploded
DLJEB
Restore exploded blocks: find the exploded pieces of a block among selected objects and put block references back.
> Block to restore [Pick/Name] <Pick>:
> [Pick] Select the block to restore:
> [Name] Block name:
> Select the exploded objects (a window over them):
> The copies may be scaled [Yes/No] <No>:
Flatten Z = 0
DLFLATB
Flatten blocks to Z = 0 (their contents, nested blocks and the references).
> Flatten [Selected/All] blocks <Selected>:
> [Selected] Select the blocks to flatten:
Make explodable
DLEXPL
Make every block in the drawing explodable.
Colour / layer inside
DLBCL
Set the colour and/or layer of the objects inside blocks (nested too).
> Select the blocks:
> Colour of the objects inside [Block/Layer/Number/Keep] (ByBlock, ByLayer, a colour, unchanged) <Block>:
> [Number] Colour number (1-255): (number; default 7; the CAD shows the default as <…>, Enter accepts it)
> Layer of the objects inside [Zero/Name/Keep] <Zero>:
> [Name] Layer name <0>:
Block → xref
DLBTX
Turn a block into an xref: save it as a DWG and replace every copy by the xref.
> Select the block to turn into an xref:
> Save the block as <<drawing folder or My Documents>\<name>.dwg>:
> [file exists] <file>.dwg exists — overwrite [Yes/No] <No>:

Attributes

Quick tools → Attributes
Quick tools → Attributes
Tile · commandWhat it doesCommand line, in order
Change attributes
DLATTC
Change attributes of selected blocks: rotation, height, colour, upright or layer.
> Select the blocks:
> Attribute tag (* = all) <*>:
> Change [Rotation/Height/Colour/Upright/Layer] <Upright>:
> [Rotation] Text angle in the drawing (degrees): (number; default 0; zero and negative allowed; the CAD shows the default as <…>, Enter accepts it)
> [Height] Text height: (number; default TEXTSIZE if > 0, else 250 mm in drawing units; the CAD shows the default as <…>, Enter accepts it)
> [Colour] Colour number (0 = ByBlock, 256 = ByLayer): (number; default 256; the CAD shows the default as <…>, Enter accepts it)
> [Layer] Layer <0>:
Hide attributes
DLINVATT
Hide attributes (selected blocks or all blocks).
> [Select/All] blocks <Select>:
> [Select] Select the blocks:
> Attribute tag (* = all) <*>:
Show attributes
DLSHOWATT
Show attributes again (selected blocks or all blocks).
> [Select/All] blocks <Select>:
> [Select] Select the blocks:
> Attribute tag (* = all) <*>:

Lines

Quick tools → Lines
Quick tools → Lines
Tile · commandWhat it doesCommand line, in order
Fillet polylines
DLMF
Fillet every corner of selected polylines with one radius.
> Select the polylines to fillet:
> Fillet radius: (number; default FILLETRAD if > 0, else 300 mm in drawing units; the CAD shows the default as <…>, Enter accepts it)
Fillet 2 sets
DLFF
Fillet two sets of parallel lines with concentric bends (e.g. a bundle of conduits turning a corner).
> Select the first set of parallel lines:
> Select the second set of parallel lines:
> Radius of the inner bend: (number; default FILLETRAD if > 0, else 300 mm in drawing units; the CAD shows the default as <…>, Enter accepts it)
Equal spacing
DLOL
Space parallel lines/polylines equally between the outer two.
> Select the parallel lines / polylines (the outer two stay):
Break at crossings
DLBBM
Break lines at their crossings with a gap.
> Select the lines / polylines / arcs:
> Gap at each crossing: (number; default 150 mm in drawing units; the CAD shows the default as <…>, Enter accepts it)
> At a crossing break the [Later/Horizontal/Vertical] one <Later>:
Close gaps
DLGAP
Close gaps in broken straight lines (merge collinear pieces).
> Select the broken lines:
> Largest gap to close: (number; default 500 mm in drawing units; the CAD shows the default as <…>, Enter accepts it)
Total length
DLTLEN
Total length of selected curves by layer (optionally as a table).
> Select lines, polylines, arcs …:
> Place a table [Yes/No] <No>:
> [Yes] Table position (top-left):
90° polyline
DL3P
Draw 90° (L-shaped) polylines from start point, end point and the side of the bend (repeats).
> Start point (Enter to finish):
> End point:
> Click on the side of the bend:
Join → polyline
DLPJL
Join lines and arcs into polylines.
> Select the lines and arcs to join:
> Join ends closer than: (number; default 1 mm in drawing units; zero allowed; the CAD shows the default as <…>, Enter accepts it)

Dimensions

Quick tools → Dimensions
Quick tools → Dimensions
Tile · commandWhat it doesCommand line, in order
Chain between blocks
DLBD
Chain dimensions between blocks in a row.
> Select the blocks in a row:
> Position of the dimension line:
Block → point X + Y
DLNN
Dimension from a block to a wall / column point in X and Y (repeats).
> Select a block (Enter to finish):
> Point on the wall / column:
Block → point X
DLHH
Dimension from a block to a wall / column point — horizontal (X) only (repeats).
> Select a block (Enter to finish):
> Point on the wall / column:
Block → point Y
DLVV
Dimension from a block to a wall / column point — vertical (Y) only (repeats).
> Select a block (Enter to finish):
> Point on the wall / column:

Text

Quick tools → Text
Quick tools → Text
Tile · commandWhat it doesCommand line, in order
Add a line
DLADDTEXT
Add a line of text at the top or bottom of texts, mtexts or multileaders.
> Select texts, mtexts or multileaders:
> Line to add:
> Add it at the [Top/Bottom] <Bottom>:
Remove a line
DLRLINE
Remove the first, last or n-th line from mtexts or multileaders.
> Select mtexts or multileaders:
> Remove the [First/Last/Number] line <Last>:
> [Number] Line number (1 = top): (number; default 2; the CAD shows the default as <…>, Enter accepts it)
Text → leader
DLAM
Turn texts into multileaders — one arrow point per text.
> Select the texts to turn into leaders:
> Arrow point for "<first 30 characters of the text>…" (Enter to stop):
Align / mirror leaders
DLMM
Align or mirror multileader texts.
> Select the multileaders:
> [Align/Mirror] the text <Align>:
> [Align] Line the texts up [Vertical/Horizontal] <Vertical>:
> [Align, Vertical] Click where the text edges should line up:
> [Align, Horizontal] Click the height for the texts:
Leader colour
DLMLC
Recolour multileaders (entity, leader line and text).
> Select the multileaders:
> Colour number (1-255, 256 = ByLayer): (number; default 1; the CAD shows the default as <…>, Enter accepts it)
Match leaders
DLFITMLD
Make multileaders match a reference multileader (text height, text width, arrow size, landing).
> Select the reference multileader:
> Select the multileaders to match it:
Find & replace
DLBFIND
Find & replace text in this drawing or in many drawings.
> Find:
> Replace with (Enter = delete it):
> Match upper / lower case [Yes/No] <No>:
> Replace in [Drawing/Files] <Drawing>:
> [Files] File dialog 'Drawings to change' (Drawings (*.dwg), multi-select)
Replace from Excel
DLTFIND
Find & replace with a word list (Excel columns from the clipboard, or an .xlsx/.csv/.txt file).
> Word list from [Clipboard/File] (column A = find, B = replace) <Clipboard>:
> [File] File dialog 'Word list: column A find, column B replace' (Excel / CSV (*.xlsx;*.csv;*.txt))
> Match upper / lower case [Yes/No] <No>:
> Replace in [Drawing/Files] <Drawing>:
> [Files] File dialog 'Drawings to change' (Drawings (*.dwg), multi-select)

Plot & xref

Quick tools → Plot & xref
Quick tools → Plot & xref
Tile · commandWhat it doesCommand line, in order
Plot all layouts
DLLPLOT
Plot all layouts (or the current one), each with its own page setup.
> Plot [All/Current] layout(s) — <n> in the drawing, each with its own page setup <All>:
Printer for all
DLLPRIN
Set the same printer / plotter on every layout.
> (numbered list of plot devices, current marked '(now)')
> Number of the printer / plotter (1-<n>): (number; default the device of the first layout; the CAD shows the default as <…>, Enter accepts it)
Pen table for all
DLLPEN
Set the same pen table (.ctb / .stb) on every layout.
> (numbered list of plot style tables, current marked '(now)')
> Number of the pen table (.ctb / .stb) (1-<n>): (number; default the table of the first layout; the CAD shows the default as <…>, Enter accepts it)
Layouts → drawings
DLL2D
Split layouts into separate drawings (one DWG per layout).
> [unsaved changes] The drawing has unsaved changes that will not be included — go on [Yes/No] <No>:
> Folder for the new drawings <<drawing folder>>:
Xref colour
DLCXR
Set the colour of xref layers (all xrefs or one picked xref).
> Colour [Pick/All] xrefs <All>:
> [Pick] Select the xref:
> Colour number (8 = grey, 252 = light grey): (number; default 8; the CAD shows the default as <…>, Enter accepts it)
Bind all xrefs
DLTBIND
Bind all loaded xrefs.
> [Insert/Bind] (Insert merges layer names, Bind keeps the xref name$0$ prefix) <Insert>:

32Place a drawing from your projects

Drop the DXF of any saved calc project into the open drawing — SLD, panel GA, UGT, STP, roof drainage, sewer / water / fire networks, sprinkler and lighting layouts … Units are converted to the drawing’s units.

1

Tool menu → Place a drawing from my projects. Signed in, My projects lists every project with a drawing — click Place. Or type a project code (from the website URL, ?p=…) and click Place.

In the drawing — command line
> Insertion point for the DesignLink drawing:
Place a drawing — designlink calc CAD
Place a drawing — designlink calc CAD
2

Click the insertion point in the drawing. The log shows “<drawing> <code>: n object(s) placed”. Free in the plugin.

33Sewer and storm-water wizards

Six steps in the palette: pipes and manholes read from the drawing → CPHEEO / rational-method design → labels, plan and L-sections back in the drawing.

1

Tool menu → Sewer network (palette wizard). 1. Project — name, code regime, design standard, design mode (Design & Build or Design Only — check what is drawn), profile control, drawing units, plot scale, pipe material → Create project.

Sewer network — designlink calc CAD
Sewer network — designlink calc CAD
2

Storm-water adds the section policy (pipe → box → trapezoid by flow), lining, side slope and freeboard.

Sewer network — designlink calc CAD
Sewer network — designlink calc CAD
3

2. Network — Select in drawing the lines and manhole symbols (Design Only: also the texts), By layers… or Whole drawing → Build network; join gaps and fix pieces without an outfall.

In the drawing — command line
> Select objects to send to DesignLink:
4

3. Outfall — Pick outfall in drawing. 4. Levels — click a level text, along an alignment, or nearest levels; type the rest. 5. Loads (buildings / point loads) or Catchments (IDF + rational method).

In the drawing — command line
> DesignLink: pick the outfall manhole:
> DesignLink: click a level text:
5

6. Design — Run design (or Run check) → reaches and manholes tables. Label the design in the drawing, the plan + L-sections and sheet sets are free in the plugin; the report and Excel need a credit.

34Troubleshooting

Most problems are a closed palette, a missing drawing or the units.

You seeDo this
Typed DESIGNLINK, no paletteWait a few seconds, then DLWINDOW. Still nothing: DLDIAG and send the text to support.
“WebView2 did not start in 25 s”Close every AutoCAD / ZWCAD, delete %LOCALAPPDATA%\DesignLink\CAD\WebView2, open again.
“WebView2 could not start” / blank paletteRun Setup again (it installs the Microsoft Edge WebView2 runtime).
“Could not load the page — check internet / proxy”The PC cannot reach calc.designlink.in; check the connection, then click the grey strip to retry.
“no reply from CAD (is a drawing open?)”Open a drawing (or click into it) and try again.
Rooms come out 1000× too big or smallSetup → Units & scale and pick the unit that gives the real size.
“no closed boundary around that point”Set the wall layer (Click a wall line) or use Rectangle / Polygon / Pick polyline for that room.
A plugin file is missing / wrong buildClose CAD, run Setup again, send DLDIAG if it repeats.
Plugin not loading in AutoCAD 2026 / 2027Run the current Setup (it installs into Program Files), restart AutoCAD.
Plugin not loading in a new ZWCADNETLOAD the ZWCAD DLL once and type DLAUTOLOAD, or run Setup again.
Sign-in code not arrivingCheck spam; the code is valid 10 minutes — sign in again for a new one.
Support: send the output of DLDIAG (and DLCHECK when a drawing operation fails) to [email protected].

35Every command

All commands the plugin adds to AutoCAD / ZWCAD. The prompts are what the command line shows.

Palette and support

CommandWhat it does
DESIGNLINKOpen the DesignLink palette (calc.designlink.in in CAD mode).
DLPALETTEAlias of DESIGNLINK — open/show the docked palette.
DLWINDOWOpen DesignLink in a separate floating window instead of the docked palette.
DLHOMEShow the palette and go to the DesignLink CAD home page.
DLLOGOUTSign out of DesignLink in the palette.
DLABOUTPrint plugin version, host CAD/version, .NET runtime and the main commands.
DLDIAGDiagnostics: print versions, dependency check, WebView2 runtime and the last 30 log lines.
DLAUTOLOADMake the CAD load the plugin at every start.

Drive shortcuts and selection

CommandWhat it does
DLSSSelect every object like the picked one: same type + layer + colour (and same block name for blocks).
DLSSLSelect every object on the same layer as the picked one.
DLSSCSelect every object with the same colour as the picked one.
DLSSBSelect every block with the same name as the picked block.
DLSSPSelect the blocks with the same name that lie inside a closed polyline / circle.
DLSSVSelect blocks with the same name and the same dynamic visibility state.
DLSSASelect all blocks carrying the same attribute (tag + value, or tag only).
DLSSOSelect objects matching the picked one on a chosen set of properties.
DLHELPList all quick tools and drive shortcuts on the command line.
DLCHECKSelf-test of this CAD: runs every drawing-only bridge method on a scratch layer and removes the test objects again.
DLQTOpen the palette on Quick tools.
DLDDrive mode → Drive home.
DLLDrive mode → Lighting.
DLPDrive mode → Power points.
DLFDrive mode → Fire alarm.
DLFLDrive mode → Fire alarm loops.
DLSDrive mode → Sprinklers.
DLWDrive mode → Wiring & looping.
DLTDrive mode → Cable tray & feeders.
DLTODrive mode → Toilet plumbing.
DLHVDrive mode → HVAC ducts & units.
DLCPDrive mode → Car-park ventilation.
DLEADrive mode → Lightning & earthing.
DLGSDrive mode → Gas suppression.
DLELDrive mode → ELV cabling & racks.
DLHFDrive mode → HVLS fans.
DLEDrive mode → Change what was placed.
DLNDrive mode → Number the devices.
DLUDrive mode → Undo the last run?.
DLCTDrive mode → Cable tray control.
DLLODrive mode → Loops.
DLAXDrive mode → Building direction.
DLQDrive mode → Quantities.
DLDXDrive mode → DIALux.
DLSETDrive mode → Setup.

Blocks

CommandWhat it does
DLRBBRename a block definition (every copy in the drawing).
DLRBGive only the selected copies of a block a new name (the others keep the old one).
DLDBDuplicate a block definition under a new name.
DLCBPRChange a block's base point without moving any copy in the drawing.
DLROT0Make a block's present rotation its normal 0° rotation.
DLSC0Make a block's present scale its scale 1.
DLROTMRotate many blocks, each about its own base point (add an angle or set an absolute angle).
DLRESBRescale many blocks, each about its own base point.
DLQBQuick block: turn selected objects into a block in one go.
DLADD2BAdd objects to a block definition without the block editor (every copy changes).
DLREMBRemove objects from a block definition by clicking them inside a block (repeats).
DLABBMCut the lines/polylines/arcs that run through blocks at the block outline.
DLFLATBFlatten blocks to Z = 0 (their contents, nested blocks and the references).
DLEXPLMake every block in the drawing explodable.
DLBCLSet the colour and/or layer of the objects inside blocks (nested too).
DLBTXTurn a block into an xref: save it as a DWG and replace every copy by the xref.
DLBREReplace selected blocks by another block, keeping position, angle, scale, layer and attribute values.
DLBRBReplace a block in other (closed) drawings by a block from this drawing.
DLD2RConvert dynamic blocks to static blocks (one static block per dynamic block + visibility state).
DLJEBRestore exploded blocks: find the exploded pieces of a block among selected objects and put block references back.

Lines and dimensions

CommandWhat it does
DLMFFillet every corner of selected polylines with one radius.
DLFFFillet two sets of parallel lines with concentric bends (e.g. a bundle of conduits turning a corner).
DLOLSpace parallel lines/polylines equally between the outer two.
DLBBMBreak lines at their crossings with a gap.
DLGAPClose gaps in broken straight lines (merge collinear pieces).
DLTLENTotal length of selected curves by layer (optionally as a table).
DL3PDraw 90° (L-shaped) polylines from start point, end point and the side of the bend (repeats).
DLPJLJoin lines and arcs into polylines.
DLBDChain dimensions between blocks in a row.
DLNNDimension from a block to a wall / column point in X and Y (repeats).
DLHHDimension from a block to a wall / column point — horizontal (X) only (repeats).
DLVVDimension from a block to a wall / column point — vertical (Y) only (repeats).

Text, plot and xrefs

CommandWhat it does
DLADDTEXTAdd a line of text at the top or bottom of texts, mtexts or multileaders.
DLRLINERemove the first, last or n-th line from mtexts or multileaders.
DLAMTurn texts into multileaders — one arrow point per text.
DLMMAlign or mirror multileader texts.
DLMLCRecolour multileaders (entity, leader line and text).
DLFITMLDMake multileaders match a reference multileader (text height, text width, arrow size, landing).
DLBFINDFind & replace text in this drawing or in many drawings.
DLTFINDFind & replace with a word list (Excel columns from the clipboard, or an .xlsx/.csv/.txt file).
DLCXRSet the colour of xref layers (all xrefs or one picked xref).
DLTBINDBind all loaded xrefs.
DLLPRINSet the same printer / plotter on every layout.
DLLPENSet the same pen table (.ctb / .stb) on every layout.
DLLPLOTPlot all layouts (or the current one), each with its own page setup.
DLL2DSplit layouts into separate drawings (one DWG per layout).
DLATTCChange attributes of selected blocks: rotation, height, colour, upright or layer.
DLINVATTHide attributes (selected blocks or all blocks).
DLSHOWATTShow attributes again (selected blocks or all blocks).