USER GUIDE

Energy code compliance — ECSBC 2024 / ASHRAE 90.1

Prescriptive checklist by climate zone and level — ECSBC 2024 (ECSBC / ECSBC+ / Super ECSBC; ECBC 2017 option) or ASHRAE 90.1: envelope U & SHGC, WWR, cool roof, lighting power density with controls, chiller COP, fan power, economizer, VFDs, insulation, transformers, motors, PF, UPS, renewable zone — proposed values pulled from the building, lighting, load and heat-load tools; EPI estimate; report and Excel.

ECSBC 2024 · ECBC 2017 option · ASHRAE 90.1-2019 · BEE

How to use it

  1. Set the regime and edition (ECSBC 2024 default, ECBC 2017 option / ASHRAE 90.1), the level (ECSBC / ECSBC+ / Super ECSBC), the city (climate zone follows) and the building type; pull the area and WWR from the building model.
  2. Type the proposed envelope (wall / roof / glass U, SHGC, VLT, SRI, skylights), pull the installed LPD from the lighting design, list the chillers, unitary units, fan systems and UPS with their efficiencies, tick the controls and measures provided.
  3. Read the checklist: every prescriptive requirement with the code value, the proposed value, PASS / FAIL and the clause; edit a requirement where your code edition differs (flagged in the report).
  4. Check the EPI estimate against the benchmark; export the checklist Excel and the compliance report.

Inputs

FieldType / defaultMeaning
Basisregime, level, city / zone, building type, area
EnvelopeWWR, U-values, SHGC, VLT, SRI, skylights, daylighting
LightingLPD, spaces, controls
HVACchillers, unitary, fans, VFDs, economizer, insulation, controls
Electricaltransformer, motors, PF, UPS, metering, renewable, SWH, lifts

What you get

OutputContent
Checklistrequirement, code value, proposed, result, clause
EPIkWh/m²/yr by component vs benchmark
Report / Excelsubmission-style compliance tables

Standards applied

Good to know