USER GUIDE
Lighting design (lux)
Room schedule → illuminance & uniformity from the luminaire's IES / LDT file (point-by-point + radiosity), automatic layout, emergency luminaires marked E, DIALux-style report, Excel BOQ, DXF layout. Shared luminaire library.
NBCS 2026 Part D Sec 1 · IS 3646 · EN 12464-1 · EN 1838
- NBCS 2026 (SP 7:2026) Part D Sec 1 — National Building Construction Standards — Lighting and natural ventilation
Illuminance and lighting quality by room (Table 6), daylight, natural ventilation
- NBCS 2026 (SP 7:2026) Part F — National Building Construction Standards — Fire and life safety
Means of egress (Tables 2–4, cl. 4.4.2), staircase / lobby / lift-well pressurisation (cl. 4.4.2.5, Table 5), emergency lighting (cl. 3.5.6), fire-fighting installations by occupancy (Tables 7A–7J), demand, pumps and duration (Tables 7K / 7M), mains (Table 8), hydrant pressure 3.5–7 bar (cl. 5.1.1 f), sprinklers (cl. 5.1.3), gaseous suppression (cl. 5.1.6 / 5.1.9)
- NBC 2016 Part 8 Sec 1 — National Building Code — Lighting and natural ventilation
Recommended illuminance by activity, uniformity, emergency lighting, daylighting
- IS 3646 (Part 1):1992 — Code of practice for interior illumination — general requirements and recommendations for working interiors
Illuminance schedule, uniformity, glare, maintenance
- SP 72:2010 — National Lighting Code (BIS)
Lighting design practice, luminaire selection, maintenance factors
- IS 1944 (Parts 1–6) — Code of practice for lighting of public thoroughfares
Outdoor / road lighting classes and levels
- ECBC 2017 (BEE) — Energy Conservation Building Code — superseded by ECSBC 2024; still enforced where a State has not yet notified ECSBC 2024
Envelope U / SHGC and lighting power density (India option)
- EN 12464-1:2021 — Light and lighting — Lighting of work places — Part 1: Indoor work places
Required Ēm, Uo, UGR, Ra by activity; calculation grid (§4.4)
- EN 12464-2:2014 — Light and lighting — Lighting of work places — Part 2: Outdoor work places
Outdoor areas, car parks, loading yards
- EN 1838:2013 — Lighting applications — Emergency lighting
Escape route 1 lx, open area 0.5 lx, uniformity 40:1, duration
- ISO 8995-1 / CIE S 008 — Lighting of work places — Part 1: Indoor
Illuminance and quality criteria (international)
- ASHRAE 90.1-2019 — Energy Standard for Buildings
Lighting power density by space type
- IES LM-63-2019 — Standard file format for the electronic transfer of photometric data
IES luminaire files (candela tables) used by the engine
- EULUMDAT — European luminaire data format (.ldt)
LDT luminaire files (cd/klm tables) used by the engine
- CIE 52 / CIE 40 — Calculations for interior lighting — applied method / basic method
Point-by-point direct illuminance and interreflection (radiosity)
- IEC 60598-1 / IS 10322 — Luminaires — general requirements and tests
Luminaire safety and IP classification