USER GUIDE

Storm water — auto design

Layout DXF + road profiles PDF in, pipes, boxes and main drain designed, validated, drawn back.

CPHEEO · IRC SP 50 · HEC-22

How to use it

  1. 1 Files — upload the planner's storm-water layout DXF as issued (node labels with leaders, manhole blocks, pipe / box-drain linework, main-drain outline, flow arrows; in the CAD palette press 'Read the open drawing') and the road plan-and-profile PDF (PROPOSED ROAD LEVEL / CHAINAGE bands plus the key plan with chainage ticks).
  2. 2 Check — what the tool read: node positions from the leader far-ends (median node → manhole distance must be < 0.5 m), the topology built from the label numbering (runs → straight segments sorted along their axis → junction / outfall links from the linework), the outfalls, the flow-arrow rule calibrated on the tree, the roads found on the key plan and their chainage origins, the level-model roads (tick the E–W profiles that span the site; the centre road is the main-drain corridor), the profile offsets (must vary smoothly — ±1.5 m jumps mean a wrong chainage origin) and the plan picture. Fix layers or roads and re-read until it looks right.
  3. 3 Inputs — the four engineer numbers: rainfall intensity, fixed outfall invert, runoff coefficients (paved / unpaved) and the catchment split; the design constants of the brief (cover to crown 0.60 m, freeboards, velocities 0.75–3 m/s, utilisation 90 / 95 %, side slope) can be changed.
  4. 4 Design — the catchment is allocated to the nodes (nearest-node partition of the site hull), flows accumulated leaf → root; the main open drain is designed upward from the fixed outfall by a uniform-gradient sweep with the top of bank kept below the finished level; every sub-drain is chosen working upstream from its outlet: smallest HDPE (1–3 barrels) that fits 0.60 m of cover, else the narrowest RCC box, else sized on hydraulics with the formation raise listed. 13 validation checks, the cover sensitivity (the lever that moves the HDPE / box split), Excel (8 sheets), A3 report, and the clean DXF overlay that drops onto the layout at 0,0 — or straight into the open drawing from the palette.

Inputs

FieldType / defaultMeaning
Layout DXFnode labels + leaders, manhole blocks, pipe and box-drain linework, main-drain outline, arrow blocks
Plan-and-profile PDFroad profiles (chainage, proposed level) and the key plan
Engineer inputsrainfall intensity, outfall invert, runoff C paved / unpaved, catchment paved / unpaved m²
Constantsn values, cover, freeboards, velocity and utilisation limits, size sets, gradient list

What you get

OutputContent
Main drainreach table with section, gradient, inverts, water surface, top of bank, bank below road; section schedule
Sub-drainsform, size, barrels, gradient, velocity, utilisation, inverts, tops, road levels; fill flag
Outfall summaryoutlet inverts vs main-drain invert and water surface
Catchmentarea and flow per node with the level source
Fill schedulereaches that need the formation raised, by how much
Validation13 checks with detail
DXF overlayMAIN DRAIN NEW · SW-HDPE · SW-BOX · SW-OUTFALL · SW-FILL · SW-LABEL · SW-KEY · REF-NODE

Standards applied

Good to know