All calculators
Structure & architecture · Live

MEP supports — spans, members, anchors

Trays, ducts and pipes need supports that a structural engineer never sees: this calculator turns the service into a load per metre, picks the cross-member (angle, strut, channel or beam) by bending and deflection for a trapeze, bracket or goal-post, and checks the hanger rod and the anchor bolt with tension–shear interaction.

IS 800:2007 / IS 800:1984NBCS 2026 (SP 7:2026) Part C Sec 1IS 1367 / IS 1363IEC 61537:2006 / IS 17237ASHRAE Handbook — HVAC Applications ch. 51SMACNA HVAC Duct Construction Standards
What goes in, what comes out

You enter

    You get

      What it does

      Service loadsLoaded ladder / perforated trays per IEC 61537 practice, duct sheet + insulation, water-filled insulated pipes, or a custom kg/m, plus the 90 kg maintenance point load.
      Member selectionIS 808 angles and channels, ISMB, strut channel — first section that passes 0.66 fy bending and L/240 deflection.
      Rods and anchorsRod by 0.6 fy with SF 1.5; anchor by indicative cracked-concrete capacities with N/Nrd + V/Vrd ≤ 1 — replace with the ETA values for issue.

      Checks it performs

      PASS / CHECKZ ≥ M / 0.66 fy
      PASS / CHECKDeflection ≤ L/240
      PASS / CHECKRod capacity with SF 1.5
      PASS / CHECKAnchor interaction ≤ 1

      Sample report

      Also searched as

      MEP support design; cable tray support span calculation; pipe support design calculator; unistrut channel load calculation; anchor bolt calculation for supports; duct hanger design. The same calculation, the same clauses — one tool for structure & architecture design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

      Standards applied

      ReferenceTitleUsed for
      IS 800:2007 / IS 800:1984General construction in steel — code of practiceAllowable bending stress 0.66 fy, deflection limits for MEP support members
      NBCS 2026 (SP 7:2026) Part C Sec 1National Building Construction Standards — Loads and load effectsImposed loads, impact allowance (cl. 3.6), wind, seismic by IS 1893 (Part 1)
      IS 1367 / IS 1363Threaded fasteners — technical supply conditions; hexagon boltsHanger rods and anchor bolts (property class 4.6 / 8.8)
      IEC 61537:2006 / IS 17237Cable management — cable tray and cable ladder systemsSafe working load, support spacing and deflection of trays and ladders
      ASHRAE Handbook — HVAC Applications ch. 51Service water heatingHot-water demand, storage and recovery
      SMACNA HVAC Duct Construction StandardsDuct construction, hangers and supports, seismic restraintDuct hanger spacing and sizes; seismic bracing spacing
      ETAG 001 / EAD 330232 (EN 1992-4)Metal anchors for use in concreteAnchor tension / shear capacities, cracked concrete, seismic categories

      Frequently asked

      How do I use the MEP supports — spans, members, anchors calculator?

      Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

      Which codes and standards does the mep supports follow?

      It applies IS 800:2007 / IS 800:1984, NBCS 2026 (SP 7:2026) Part C Sec 1, IS 1367 / IS 1363, IEC 61537:2006 / IS 17237, ASHRAE Handbook — HVAC Applications ch. 51, SMACNA HVAC Duct Construction Standards and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

      What does it check?

      Every run is marked PASS or CHECK against: Z ≥ M / 0.66 fy; Deflection ≤ L/240; Rod capacity with SF 1.5; Anchor interaction ≤ 1.

      Is the calculator free to use?

      Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

      Can I see a sample report before I use it?

      Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/supports/ — inputs, results with basis, checks, worked example, drawing and the standards list.

      Is this the same as a MEP support design?

      Yes. People also call it a cable tray support span calculation, a pipe support design calculator, a unistrut channel load calculation. It covers the same calculation under structure & architecture design, with the Indian and international code regimes selectable.

      Does it work with AutoCAD or ZWCAD?

      Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

      Related structure & architecture calculators