MEP supports — spans, members, anchors
Trays, ducts and pipes need supports that a structural engineer never sees: this calculator turns the service into a load per metre, picks the cross-member (angle, strut, channel or beam) by bending and deflection for a trapeze, bracket or goal-post, and checks the hanger rod and the anchor bolt with tension–shear interaction.
You enter
You get
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
MEP support design; cable tray support span calculation; pipe support design calculator; unistrut channel load calculation; anchor bolt calculation for supports; duct hanger design. The same calculation, the same clauses — one tool for structure & architecture design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| IS 800:2007 / IS 800:1984 | General construction in steel — code of practice | Allowable bending stress 0.66 fy, deflection limits for MEP support members |
| NBCS 2026 (SP 7:2026) Part C Sec 1 | National Building Construction Standards — Loads and load effects | Imposed loads, impact allowance (cl. 3.6), wind, seismic by IS 1893 (Part 1) |
| IS 1367 / IS 1363 | Threaded fasteners — technical supply conditions; hexagon bolts | Hanger rods and anchor bolts (property class 4.6 / 8.8) |
| IEC 61537:2006 / IS 17237 | Cable management — cable tray and cable ladder systems | Safe working load, support spacing and deflection of trays and ladders |
| ASHRAE Handbook — HVAC Applications ch. 51 | Service water heating | Hot-water demand, storage and recovery |
| SMACNA HVAC Duct Construction Standards | Duct construction, hangers and supports, seismic restraint | Duct hanger spacing and sizes; seismic bracing spacing |
| ETAG 001 / EAD 330232 (EN 1992-4) | Metal anchors for use in concrete | Anchor tension / shear capacities, cracked concrete, seismic categories |
Frequently asked
How do I use the MEP supports — spans, members, anchors calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the mep supports follow?
It applies IS 800:2007 / IS 800:1984, NBCS 2026 (SP 7:2026) Part C Sec 1, IS 1367 / IS 1363, IEC 61537:2006 / IS 17237, ASHRAE Handbook — HVAC Applications ch. 51, SMACNA HVAC Duct Construction Standards and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Z ≥ M / 0.66 fy; Deflection ≤ L/240; Rod capacity with SF 1.5; Anchor interaction ≤ 1.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/supports/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a MEP support design?
Yes. People also call it a cable tray support span calculation, a pipe support design calculator, a unistrut channel load calculation. It covers the same calculation under structure & architecture design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.