USER GUIDE

Acoustics & NC rating

Level addition, distance and barrier, octave-band NC and dB(A).

ASHRAE ch. 8

How to use it

  1. Enter the inputs on the left — defaults are a typical case; every field has a note.
  2. Results, checks (PASS / CHECK) and worked steps appear on the right as you type; Drawing and 3D tabs where the calculation has a layout.
  3. Save the project, then export the Report, Excel with formulas.

Inputs

FieldType / defaultMeaning
Code basis & room
Design regimechoice default india
India — NBCS 2026 D3 Table 1 (NC) + D4 Table 4 (dB(A)), International — NC target entered (ASHRAE)
Room type (NBCS D3 Table 1 / D4 Table 4)choice default office_private
Residences, apartments, Hospitality — individual rooms / suites, Hospitality — meeting / banquet rooms, Hospitality — corridors, lobbies, Hospitality — service / support areas, All-day dining and restaurants, Office — executive and private offices, Office — conference rooms …
Acoustic classchoice default B
A — aspirational, B — acceptable, C — minimum acceptable
Class-room floor areanumber (m²) default 60
Sources to add
Source 1 levelnumber (dB) default 75
Source 2 levelnumber (dB) default 72
Source 3 levelnumber (dB) default 0
Source 4 levelnumber (dB) default 0
Distance
Reference distancenumber (m) default 1
Receiver distancenumber (m) default 10
Source typechoice default point
Point (−6 dB per doubling), Line (−3 dB per doubling)
Barrier / enclosure attenuationnumber (dB) default 0
Octave-band levels at the receiver (blank = not used)
63 Hznumber (dB) default 60
125 Hznumber (dB) default 55
250 Hznumber (dB) default 50
500 Hznumber (dB) default 45
1000 Hznumber (dB) default 42
2000 Hznumber (dB) default 40
4000 Hznumber (dB) default 38
8000 Hznumber (dB) default 35
NC target override (blank = NBCS D3 Table 1 for the room; international default NC-35)number

What you get

OutputContent
Results, checks, worked steps, schedules; report, Excel and DXF exports.

Standards applied

Good to know