Room volume × air changes → airflow, number and sweep of exhaust fans, make-up air opening.
ASHRAE 62.1 · practice
| Field | Type / default | Meaning |
|---|---|---|
| Room | ||
| Length | number (m) default 4 | |
| Width | number (m) default 3 | |
| Height | number (m) default 3 | |
| Use (air changes, typical) | choice default toilet | Toilet / bathroom — 10 ACH, Domestic kitchen — 15 ACH, Commercial kitchen (without hood calculation) — 30 ACH, Store — 6 ACH, Plant / pump room — 10 ACH, Laundry — 15 ACH, Garage / small parking — 6 ACH, Office (no AC) — 6 ACH … |
| Air changes per hour (custom) | number default 10 | |
| Fans | ||
| Number of fans (0 = choose) | number default 0 | |
| Derating for louvre / short duct | number (%) default 20 | |
| Velocity through the make-up opening | number (m/s) default 2.0 | |
| Output | Content |
|---|---|
| Results, checks, worked steps, schedules; report, Excel and DXF exports. | |