USER GUIDE

Swimming pool plant

Turnover, filters, pumps, heating, plant room laid out with DXF and 3D.

NBCS 2026 Part E · PWTAG · IS 3328

How to use it

  1. Enter the inputs on the left — defaults are a typical case; every field has a note.
  2. Results, checks (PASS / CHECK) and worked steps appear on the right as you type; Drawing and 3D tabs where the calculation has a layout.
  3. Save the project, then export the Report, Excel with formulas and DXF.

Inputs

FieldType / defaultMeaning
Pool
Design basischoice default nbcs2026NBCS 2026 cl. 4.19.1.2: private outdoor 6 h, private indoor 10 h, public 6 h, competition 6 h, wading 1 h, spa public ½ h / private 1 h; cl. 4.19.1.3: 2.2 / 2.7 / 4.0 m² per user for depths ≤ 1 / ≤ 1.5 / > 1.5 m
NBCS 2026 Part E Sec 1 cl. 4.19 — turnover table, user load by depth, displacement 60 / 45 L, PWTAG / IS 3328 practice (stricter turnover for public pools)
Pool typechoice default hotelHotel / club = public pool under NBCS 2026
Residential / villa, Hotel / club leisure, Competition / training (25–50 m), Kids / teaching pool (≤ 1 m), Spa / jacuzzi, Spa / jacuzzi — private
Lengthnumber (m) default 25
Widthnumber (m) default 12.5
Depth — shallow endnumber (m) default 1.2
Depth — deep endnumber (m) default 2.0
Edge typechoice default deck
Deck-level / overflow channel (balance tank), Skimmer (no balance tank)
Indoor poolyes / no default False
Turnover period (blank = by type)number (h)
Area per bather (blank = by type)number (m²)
Filtration and pumps
Filtration rate (blank = by type)number (m/h)PWTAG: ≤ 25 m/h medium-rate for public pools, ≤ 30–40 high-rate residential, 10–15 kids
Number of filters (0 = auto, ≥ 2 for public)number default 0
Backwash ratenumber (m/h) default 40
Backwash durationnumber (min) default 6
Pump head (blank = estimate: static + filter + heater + pipes)number (m)
Circulation pipe run (plant room → pool, one way)number (m) default 30
Pump + motor efficiencynumber (%) default 60
Standby pumpyes / no default True
Heating
Heatingchoice default hp
Heat pump, Gas / electric boiler via heat exchanger, Solar thermal + heat-pump backup, Unheated
Pool water temperaturenumber (°C) default 28
Design ambient air (coldest month)number (°C) default 15
Relative humiditynumber (%) default 60
Air speed over water (indoor 0.15, outdoor 2–4)number (m/s) default 2.0
Fill / make-up water temperaturenumber (°C) default 18
Initial heat-up timenumber (h) default 48
Pool cover at night (evaporation × 0.3 for 12 h)yes / no default False
Heat-pump COP at designnumber default 4.5
Water treatment
Secondary disinfectionchoice default uv
Medium-pressure UV (60 mJ/cm²), Ozone (1 g/m³ side-stream), Chlorine only
Free chlorine residualnumber (mg/L) default 1.5
Hypochlorite strengthnumber (% available Cl) default 12
Operating hours per daynumber (h) default 12
Plant room
Plant room sizechoice default auto
Auto — minimum that fits the equipment, Given below (check fit)
Plant room lengthnumber (m) default 10
Plant room widthnumber (m) default 6
Clear heightnumber (m) default 3.5

What you get

OutputContent
Results, checks, worked steps, schedules; report, Excel and DXF exports.

Standards applied

Good to know