Turnover, filters, pumps, heating, plant room laid out with DXF and 3D.
NBCS 2026 Part E · PWTAG · IS 3328
| Field | Type / default | Meaning |
|---|---|---|
| Pool | ||
| Design basis | choice default nbcs2026 | NBCS 2026 cl. 4.19.1.2: private outdoor 6 h, private indoor 10 h, public 6 h, competition 6 h, wading 1 h, spa public ½ h / private 1 h; cl. 4.19.1.3: 2.2 / 2.7 / 4.0 m² per user for depths ≤ 1 / ≤ 1.5 / > 1.5 m NBCS 2026 Part E Sec 1 cl. 4.19 — turnover table, user load by depth, displacement 60 / 45 L, PWTAG / IS 3328 practice (stricter turnover for public pools) |
| Pool type | choice default hotel | Hotel / club = public pool under NBCS 2026 Residential / villa, Hotel / club leisure, Competition / training (25–50 m), Kids / teaching pool (≤ 1 m), Spa / jacuzzi, Spa / jacuzzi — private |
| Length | number (m) default 25 | |
| Width | number (m) default 12.5 | |
| Depth — shallow end | number (m) default 1.2 | |
| Depth — deep end | number (m) default 2.0 | |
| Edge type | choice default deck | Deck-level / overflow channel (balance tank), Skimmer (no balance tank) |
| Indoor pool | yes / no default False | |
| Turnover period (blank = by type) | number (h) | |
| Area per bather (blank = by type) | number (m²) | |
| Filtration and pumps | ||
| Filtration rate (blank = by type) | number (m/h) | PWTAG: ≤ 25 m/h medium-rate for public pools, ≤ 30–40 high-rate residential, 10–15 kids |
| Number of filters (0 = auto, ≥ 2 for public) | number default 0 | |
| Backwash rate | number (m/h) default 40 | |
| Backwash duration | number (min) default 6 | |
| Pump head (blank = estimate: static + filter + heater + pipes) | number (m) | |
| Circulation pipe run (plant room → pool, one way) | number (m) default 30 | |
| Pump + motor efficiency | number (%) default 60 | |
| Standby pump | yes / no default True | |
| Heating | ||
| Heating | choice default hp | Heat pump, Gas / electric boiler via heat exchanger, Solar thermal + heat-pump backup, Unheated |
| Pool water temperature | number (°C) default 28 | |
| Design ambient air (coldest month) | number (°C) default 15 | |
| Relative humidity | number (%) default 60 | |
| Air speed over water (indoor 0.15, outdoor 2–4) | number (m/s) default 2.0 | |
| Fill / make-up water temperature | number (°C) default 18 | |
| Initial heat-up time | number (h) default 48 | |
| Pool cover at night (evaporation × 0.3 for 12 h) | yes / no default False | |
| Heat-pump COP at design | number default 4.5 | |
| Water treatment | ||
| Secondary disinfection | choice default uv | Medium-pressure UV (60 mJ/cm²), Ozone (1 g/m³ side-stream), Chlorine only |
| Free chlorine residual | number (mg/L) default 1.5 | |
| Hypochlorite strength | number (% available Cl) default 12 | |
| Operating hours per day | number (h) default 12 | |
| Plant room | ||
| Plant room size | choice default auto | Auto — minimum that fits the equipment, Given below (check fit) |
| Plant room length | number (m) default 10 | |
| Plant room width | number (m) default 6 | |
| Clear height | number (m) default 3.5 | |
| Output | Content |
|---|---|
| Results, checks, worked steps, schedules; report, Excel and DXF exports. | |