Strings against the inverter window, monthly yield by city, cables, payback.
IEC 62548 · CEA
| Field | Type / default | Meaning |
|---|---|---|
| Site | ||
| City (irradiance & temperature) | choice default delhi | Delhi NCR, Mumbai, Chennai, Kolkata, Bengaluru, Hyderabad, Ahmedabad, Pune … |
| Latitude | number (°N) default 20 | |
| Annual GHI | number (kWh/m²/yr) default 1850 | |
| Record minimum ambient (cold Voc) | number (°C) default 2 | |
| Design maximum ambient (hot Vmp) | number (°C) default 45 | |
| Module tilt (blank = latitude, min 10°) | number (°) | |
| Azimuth off true south (0 = south, ±90 = E/W) | number (°) default 0 | |
| Ground / roof albedo | number default 0.2 | |
| Array | ||
| Size the array by | choice default kwp | Target DC capacity, Fill the available roof |
| Target DC capacity | number (kWp) default 100 | |
| Roof length (E–W) | number (m) default 45 | |
| Roof width (N–S) | number (m) default 30 | |
| Edge setback / walkway | number (m) default 1.0 | |
| Module orientation in the row | choice default portrait | Portrait, 1 module high, Portrait, 2 modules high, Landscape, 1 module high, Landscape, 2 modules high |
| Module (STC datasheet) | ||
| Pmax | number (Wp) default 550 | |
| Voc | number (V) default 49.8 | |
| Vmp | number (V) default 41.9 | |
| Isc | number (A) default 14.0 | |
| Imp | number (A) default 13.1 | |
| Temp. coefficient of Voc | number (%/°C) default -0.27 | |
| Temp. coefficient of Pmax | number (%/°C) default -0.35 | |
| NOCT | number (°C) default 45 | |
| Module length | number (m) default 2.278 | |
| Module width | number (m) default 1.134 | |
| Max series fuse rating | number (A) default 25 | |
| Inverter | ||
| Rated AC output (each) | number (kW) default 50 | |
| Max DC input voltage | number (V) default 1100 | |
| MPPT window — min | number (V) default 200 | |
| MPPT window — max | number (V) default 1000 | |
| Number of MPPTs | number default 4 | |
| Max input current per MPPT | number (A) default 32 | |
| String inputs per MPPT | number default 2 | |
| Target DC / AC ratio | number default 1.2 | |
| Euro efficiency | number (%) default 98.0 | |
| AC voltage | choice default 415 | 415 V three-phase (India), 400 V three-phase (IEC), 380 V three-phase, 480 V three-phase, 230 V single-phase (≤ 10 kW), 240 V single-phase, Custom — enter below |
| Custom AC voltage (line-line for 3-ph, ≤ 300 V treated as single-phase) | number (V) default 415 | |
| Transformerless inverter (needs Type B / 300 mA RCD per IEC 62109) | yes / no default True | |
| Losses | ||
| Soiling | number (%) default 3 | |
| Near shading | number (%) default 1 | |
| Mismatch + LID | number (%) default 2.5 | |
| DC wiring | number (%) default 1.5 | |
| AC wiring + transformer | number (%) default 1.0 | |
| Availability / downtime | number (%) default 1.0 | |
| Cables | ||
| String cable run (one way, longest) | number (m) default 40 | |
| DC voltage drop limit | number (%) default 1.5 | |
| AC cable inverter → ACDB / LT panel | number (m) default 60 | |
| AC conductor | choice default auto | Auto — copper up to 50 mm², aluminium above (NBCS 2026 D2 10.8), Aluminium XLPE armoured, Copper XLPE armoured |
| AC voltage drop limit | number (%) default 1.0 | |
| Economics | ||
| Installed cost | number (₹/kWp) default 45000 | |
| Grid tariff offset | number (₹/kWh) default 8.0 | |
| Annual degradation | number (%/yr) default 0.55 | |
| Grid emission factor | number (kg CO₂/kWh) default 0.716 | |
| Output | Content |
|---|---|
| Results, checks, worked steps, schedules; report, Excel and DXF exports. | |