USER GUIDE

Rooftop solar PV

Strings against the inverter window, monthly yield by city, cables, payback.

IEC 62548 · CEA

How to use it

  1. Enter the inputs on the left — defaults are a typical case; every field has a note.
  2. Results, checks (PASS / CHECK) and worked steps appear on the right as you type; Drawing and 3D tabs where the calculation has a layout.
  3. Save the project, then export the Report, Excel with formulas and DXF.

Inputs

FieldType / defaultMeaning
Site
City (irradiance & temperature)choice default delhi
Delhi NCR, Mumbai, Chennai, Kolkata, Bengaluru, Hyderabad, Ahmedabad, Pune …
Latitudenumber (°N) default 20
Annual GHInumber (kWh/m²/yr) default 1850
Record minimum ambient (cold Voc)number (°C) default 2
Design maximum ambient (hot Vmp)number (°C) default 45
Module tilt (blank = latitude, min 10°)number (°)
Azimuth off true south (0 = south, ±90 = E/W)number (°) default 0
Ground / roof albedonumber default 0.2
Array
Size the array bychoice default kwp
Target DC capacity, Fill the available roof
Target DC capacitynumber (kWp) default 100
Roof length (E–W)number (m) default 45
Roof width (N–S)number (m) default 30
Edge setback / walkwaynumber (m) default 1.0
Module orientation in the rowchoice default portrait
Portrait, 1 module high, Portrait, 2 modules high, Landscape, 1 module high, Landscape, 2 modules high
Module (STC datasheet)
Pmaxnumber (Wp) default 550
Vocnumber (V) default 49.8
Vmpnumber (V) default 41.9
Iscnumber (A) default 14.0
Impnumber (A) default 13.1
Temp. coefficient of Vocnumber (%/°C) default -0.27
Temp. coefficient of Pmaxnumber (%/°C) default -0.35
NOCTnumber (°C) default 45
Module lengthnumber (m) default 2.278
Module widthnumber (m) default 1.134
Max series fuse ratingnumber (A) default 25
Inverter
Rated AC output (each)number (kW) default 50
Max DC input voltagenumber (V) default 1100
MPPT window — minnumber (V) default 200
MPPT window — maxnumber (V) default 1000
Number of MPPTsnumber default 4
Max input current per MPPTnumber (A) default 32
String inputs per MPPTnumber default 2
Target DC / AC rationumber default 1.2
Euro efficiencynumber (%) default 98.0
AC voltagechoice default 415
415 V three-phase (India), 400 V three-phase (IEC), 380 V three-phase, 480 V three-phase, 230 V single-phase (≤ 10 kW), 240 V single-phase, Custom — enter below
Custom AC voltage (line-line for 3-ph, ≤ 300 V treated as single-phase)number (V) default 415
Transformerless inverter (needs Type B / 300 mA RCD per IEC 62109)yes / no default True
Losses
Soilingnumber (%) default 3
Near shadingnumber (%) default 1
Mismatch + LIDnumber (%) default 2.5
DC wiringnumber (%) default 1.5
AC wiring + transformernumber (%) default 1.0
Availability / downtimenumber (%) default 1.0
Cables
String cable run (one way, longest)number (m) default 40
DC voltage drop limitnumber (%) default 1.5
AC cable inverter → ACDB / LT panelnumber (m) default 60
AC conductorchoice default auto
Auto — copper up to 50 mm², aluminium above (NBCS 2026 D2 10.8), Aluminium XLPE armoured, Copper XLPE armoured
AC voltage drop limitnumber (%) default 1.0
Economics
Installed costnumber (₹/kWp) default 45000
Grid tariff offsetnumber (₹/kWh) default 8.0
Annual degradationnumber (%/yr) default 0.55
Grid emission factornumber (kg CO₂/kWh) default 0.716

What you get

OutputContent
Results, checks, worked steps, schedules; report, Excel and DXF exports.

Standards applied