WCs, urinals, wash basins, drinking water and accessible toilets for the occupants (NBCS 2026 Part E Sec 2 Tables 1–17), ECS parking from the bye-law ratio with two-wheeler, EV and accessible shares.
NBCS 2026 Part E · URDPFI
| Field | Type / default | Meaning |
|---|---|---|
| Occupancy | ||
| Occupancy (NBCS 2026 Part E Sec 2 table) | choice default office | Office buildings — Table 1, Factories — Table 2, Warehouse and storage area (new in NBCS 2026) — Table 3, Cinema, multiplex, concert / convention halls, theatres, stadia — Table 4, Art galleries, libraries, indoor activity / sports rooms, museums — Table 5, Hospitals with indoor patient wards — Table 6, Hospitals — outdoor patient department — Table 7, Hospitals — administrative buildings — Table 8 … |
| Code edition (offices) | choice default nbcs2026 | NBCS 2026 (SP 7:2026) Part E Sec 2 Table 1, NBC 2016 Part 9 Sec 2 Table 1 (same counts as NBCS Table 1) |
| Floors served | number default 1 | cleaner's sinks, drinking water and accessible toilets are per floor |
| Wards | number default 1 | |
| Guest rooms (cleaner's sinks 1 per 30) | number default 0 | |
| Occupants | ||
| Floor area (built-up, for parking and the population) | number (m²) default 5000 | |
| Main population (0 = from area where NBCS E1 4.1 gives a rate) | number default 0 | offices: occupants; factories / warehouses: workers; cinemas, restaurants, food courts: seats; hospitals IPD: beds; OPD: patients + attendants; schools: pupils; hostels: residents; stations: passengers; malls / markets: floating public; residences: dwelling units |
| Second group — staff / offices / visitors (0 = none) | number default 0 | |
| Male share (blank = table note: 50 %, stations / airports 60 %) | number (%) | |
| Visitors (offices: added to the common toilets; hostels: visitors' rooms) | number (%) default 0 | NBCS E1 4.1 Note 2: 5–15 % visitors / floating population depending on the use |
| Crèche children (0 = none) | number default 0 | |
| Parking ratio | ||
| Equivalent car spaces per 100 m² | number default 2.0 | URDPFI / typical bye-laws: office 1.5–3, mall 3–4, residential 1–2 per unit, hospital 2–4 per 100 m² — use the local bye-law |
| Two-wheeler ECS share | number (%) default 20 | |
| Area per ECS incl. aisles (basement) | number (m²) default 35 | |
| EV-ready share | number (%) default 20 | |
| Accessible spaces (min) | number default 2 | |
| Output | Content |
|---|---|
| Results, checks, worked steps, schedules; report, Excel and DXF exports. | |