USER GUIDE

STP design

MBBR / ASP / SBR / MBR train, layout, GA DXF, P&ID, live Excel and 3D.

CPHEEO · CPCB 2019

How to use it

  1. Fill the inputs on the left — results update as you type; every field has a short note under it.
  2. Use the tabs on the right: Results (checks, sections, worked steps), Plan / GA views, Flow / SLD, 3D, Schedules.
  3. Save the project (code in the URL) to come back or share it.
  4. Export the Report, Excel (live formulas) and DXF from the top bar.

Inputs

FieldType / defaultMeaning
Design basis
Daily average sewage flownumber (kL/day) default 1600Design capacity. From the Water tool: 80 % of the domestic water demand (CPHEEO return factor; demand per NBCS 2026 Part E Sec 1 cl. 4.1.1 / Table 1) plus any laundry / kitchen effluent.
Design working hoursnumber (h) default 24
Peak factornumber (×) default 2.5NCRPB para 3.2.5 / CPHEEO: 2.5 for small flows, 2.25 up to 50 000 population, 2.0 above
Raw sewage BOD (design)number (mg/L) default 350Sheet: 250–450 mg/L range, 350 design
Raw sewage suspended solidsnumber (mg/L) default 300
Raw sewage CODnumber (mg/L) default 650
Oil & greasenumber (mg/L) default 75
Treated effluent standardchoice default reuse5
Reuse — BOD < 5, SS < 5, COD < 50 (flushing / HVAC, sample), NGT / CPCB 2019 — BOD < 10, SS < 20, CPCB discharge — BOD < 20, SS < 30, COD < 100, CPCB general — BOD < 30, SS < 50
Parallel treatment streamsnumber (nos) default 2Sample: two-stage STP 800 + 800 KLD — anoxic, MBBR and tube settler split in two streams
Process
Biological processchoice default mbbrNBCS 2026 Part E Sec 2 cl. 4.13.3: EAASP, SBR, MBR, RBBR, MBBR (FBBR), SAFF …; packaged STPs (PSTP) to IS 18797:2024 (cl. 4.13.3 (j))
MBBR — anoxic + 2-stage moving bed (sample), Extended aeration (activated sludge), SBR — sequencing batch reactor, MBR — membrane bioreactor
Anoxic tank HRTnumber (h) default 2CPHEEO detention 1–1.2 h (p. 208); sheet uses 2 h. 0 = no anoxic tank
MBBR media BOD loading ratenumber (kg BOD/m²·d) default 0.02Bengtson, MBBR Wastewater Treatment Process p. 12; media manufacturer TDS
Media specific surface areanumber (m²/m³) default 400PP Aqua / PVA gel manufacturer
Media fill fraction of tank volumenumber (fraction) default 0.15Sheet 15 %; PP media typically 30–50 %
MBBR stages in seriesnumber (nos) default 2
F/M rationumber (kg BOD/kg MLSS·d) default 0.1Extended aeration 0.05–0.15 (CPHEEO)
MLSSnumber (mg/L) default 3500ASP 3000–5000; MBR 8000–12000
MLSS (MBR)number (mg/L) default 9000
Membrane fluxnumber (LMH) default 20Hollow-fibre / flat-sheet MBR net flux 15–25 L/m²·h
SBR basinsnumber (nos) default 2
Cycles per basin per daynumber (nos) default 4
Fill (decant) fraction of basin volumenumber (fraction) default 0.3
Aeration (react) hours per basin per daynumber (h) default 12Blowers are sized for the basins aerated at the same time
Decant time per cyclenumber (h) default 1
Membrane scour air (SADm)number (m³/m²·h) default 0.25Hollow-fibre 0.2–0.4; flat sheet 0.3–0.6 (vendor)
Oxygen per kg BOD removednumber (kg/kg) default 1.4
Oxygen transfer efficiencynumber (%) default 14Fine-bubble diffusers at 4–5 m depth: 12–20 %
Tube settler surface overflow ratenumber (m³/m²·d) default 35CPHEEO Table 5.8 secondary settling 25–40 m³/m²·d; tube settlers up to 60
Tube-settler media heightnumber (m) default 0.75
Hydraulic units
Velocity through screen openingnumber (m/s) default 0.9CPHEEO 0.6–1.2 m/s (ch. 5 p. 30); the sheet sizes the opening at 0.6 m/s
O&G chamber retention at peaknumber (min) default 6KSPCB 5–10 min
Equalisation tank HRTnumber (h) default 10EPC sheet 8–12 h; also ≥ peak flow × peak hours
Peak hours per day (EQT)number (h) default 3
Clear water tank HRTnumber (h) default 2
Excess sludge, fraction of BOD removednumber (fraction) default 0.35Sheet 30–35 % of BOD removed
Inorganic fraction of influent solidsnumber (fraction) default 0.25
Solids in settled sludgenumber (%) default 1.0
Sludge storagenumber (days) default 4Sheet: 4 days (screw-press backup)
Flushing / treated water tankchoice default nbcs
NBCS 2026 — 1 day of flushing demand in the tank + ½ day in the OHT (Part E Sec 1 cl. 4.4.10 (3)), Hours of average flow (reference sheet: 10 h), Capacity kL, None (treated water to drain)
Population using recycled flushing water (0 = from the flow)number (persons) default 00 = Q ÷ (0.8 × 135 lpcd): the population whose sewage the plant treats (CPHEEO 80 % return; NBCS cl. 4.1.1)
Flushing demandnumber (lpcd) default 30NBCS 2026 Part E Sec 1 cl. 4.1.1.1: 30 lpcd of the 135 / 100 lpcd (NBC 2016: 45)
Retention in flushing tanknumber (h) default 10
Flushing tank capacitynumber (kL) default 500
Soft water demand (0 = no softener / tank)number (kL/day) default 240Sample: 240 kL soft water tank for HVAC make-up
Ultrafiltration polishing (UF plant)yes / no default True
UV disinfectionyes / no default True
Irrigation / horticulture draw (0 = no irrigation pump)number (kL/day) default 100
Equipment basis
Pump / filter operating hours per daynumber (h) default 20
MGF / ACF filtration ratenumber (m/h) default 16Metcalf & Eddy 5–25 m³/m²·h
Chlorine dosenumber (mg/L) default 5
Hypochlorite solution strengthnumber (%) default 1
Screw press capacitynumber (m³/h) default 3
Sludge recirculation, fraction of raw flownumber (fraction) default 0.65
Blower pressure providednumber (m WC) default 5
Mixing air for EQT / SHTnumber (m³/h per m³) default 0.8Sheet: 80 % of tank volume per hour
Air per fine-bubble diffusernumber (m³/h) default 6
Incoming sewer and levels
Incoming sewer invert level at the STPnumber (m (GL = 0)) default -1.0Invert of the gravity sewer where it enters the screen chamber, relative to the same datum as the tank top (GL / basement floor = 0). Sets the screen, O&G and EQT water levels; a deep invert makes the EQT deeper.
Incoming sewer size (0 = size it for the peak flow)number (mm) default 0
Raw sewage transfer pumpschoice default auto
Auto — dry in the plant room unless the EQT is > 0.6 m deeper than the other tanks, Dry-installed in the plant room (flooded suction), Submersible in the EQT (guide rails)
Tank construction
Water depth (biological tanks)number (m) default 4.5Sample 7 m deep tanks with walkway at −2.9; fine-bubble aeration 4–6 m
Maximum water depth (auto-deepen limit)number (m) default 6.0
Free boardnumber (m) default 0.5
Cover / walkway slab above tanks (0 = open tanks with railing)number (m) default 0.0Basement STP: walkway grating over the tanks; enter the earth cover for a buried plant
Wall thicknessnumber (m) default 0.3
Base slab thicknessnumber (m) default 0.35
Top slab / walkway thicknessnumber (m) default 0.25
Water depth of screen / O&G chambersnumber (m) default 1.2
Space available (rectangle or irregular polygon)
Space given aschoice default rect
Rectangle L × B, Polygon vertices (irregular), No constraint — size the footprint
Length availablenumber (m) default 60
Width availablenumber (m) default 26
Vertices x,y in metres, one per line or ';' separatedtext default 0,0; 62,0; 62,28; 30,28; 0,12Any simple polygon; the tool finds the largest rectangle inside it (sample plot is a trapezium).
Preferred length (tanks along)number (m) default 60
Plant (pump) room width — minimumnumber (m) default 8Pumps stand along the tank walls in front of the tank they draw from; blowers, filters, UF, screw press, dosing and panel in rows with 1 m aisles. The room grows to take them.
Allow the plant room to widen to fit the equipmentyes / no default TrueOff: the width stays as entered and the room only gets longer
Arrangementchoice default auto
Auto — smallest footprint, Plant room along one side of the tanks, Central plant room, streams on both sides
Long axischoice default auto
Auto (best fit), Along the longer side, Along the shorter side
Deepen the tanks (up to the maximum) if the space is shortyes / no default True

What you get

OutputContent
Sizingevery unit process (MBBR / ASP / SBR / MBR with its own equipment), blowers, pumps, dosing
Layout & levelscompact plan with every tank on the plant room, equipment always inside, hydraulic profile from the incoming sewer invert
Piping & sleevessuctions, deliveries, headers, air, gravity legs with DN; sleeve schedule with CL / invert and wall elevations
Drawingsplan, sections, sleeve elevations, P&ID, 3D, DXF, Excel

Standards applied

Good to know