Lift-well pressurisation
Lift-shaft pressurisation: landing-door leakage (0.06 m² each, BS EN 12101-6) or the door gaps, shaft walls and vent, the landing doors open at the fire floor and the access level, the landing-door operating limit, the stack effect over the shaft height, injection points, relief, fan and riser.
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
lift well pressurization calculation; lift shaft pressurisation fan sizing; elevator hoistway pressurization; lift landing door leakage 0.06 m2; NBC lift shaft pressurisation. The same calculation, the same clauses — one tool for fire fighting design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| NBC 2016 Part 4 | National Building Code — Fire and life safety | Occupant load (Table 5), exit width (Table 22), travel distance (Table 21), stair widths |
| BS EN 12101-6:2005 | Smoke and heat control systems — Specification for pressure differential systems — Kits | System classes A–F, design pressure differences and open-door air speeds, door-opening force, leakage areas of doors / windows (Annex A), calculation method |
| BS EN 12101-13:2022 | Smoke and heat control systems — Pressure differential systems (PDS) — Design and calculation methods, installation, acceptance testing, routine testing and maintenance | Design and calculation of pressurised stairs, lobbies and lift wells; commissioning (pressure difference doors closed, air speed doors open) |
| NFPA 92 (2021) | Smoke control systems | Pressurisation and smoke-exhaust design and acceptance |
| NFPA 101:2021 | Life Safety Code | Means of egress (international option) |
| ASHRAE Handbook of Smoke Control Engineering (2012) | Klote, Milke, Turnbull, Kashef, Ferreira — Handbook of Smoke Control Engineering | Flow through leakage paths, wall / floor leakage ratios, stack effect in pressurised stairwells and lift shafts, door-opening force |
| BS 9999:2017 | Fire safety in the design, management and use of buildings — Code of practice | Protected stairs, fire-fighting shafts and lobbies, when pressurisation is used in place of natural ventilation |
| EN 81-72:2020 | Firefighters lifts | Fire-fighter lift features |
Frequently asked
How do I use the Lift-well pressurisation calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the lift-well pressurisation follow?
It applies NBC 2016 Part 4, BS EN 12101-6:2005, BS EN 12101-13:2022, NFPA 92 (2021), NFPA 101:2021, ASHRAE Handbook of Smoke Control Engineering (2012) and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Design ΔP ≤ landing-door limit; ΔP over the height within the band; Injection points; Relief damper area.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Is this the same as a lift well pressurization calculation?
Yes. People also call it a lift shaft pressurisation fan sizing, a elevator hoistway pressurization, a lift landing door leakage 0.06 m2. It covers the same calculation under fire fighting design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.