Fire tank & pump room
Fire static tank in compartments, electric + diesel + jockey pump sets for hydrant, sprinkler and water curtain per NBCS 2026 Part F Tables 7A–7M (NBC 2016 Table 7 option), air vessels, diesel day tanks, brigade inlet and draw-out connections, inside the UGT / pump-room tool with layout, DXF and 3D.
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
fire pump sizing calculator; fire tank capacity NBC 2016; fire pump room design. The same calculation, the same clauses — one tool for fire fighting design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| NBCS 2026 (SP 7:2026) Part F | National Building Construction Standards — Fire and life safety | Means of egress (Tables 2–4, cl. 4.4.2), staircase / lobby / lift-well pressurisation (cl. 4.4.2.5, Table 5), emergency lighting (cl. 3.5.6), fire-fighting installations by occupancy (Tables 7A–7J), demand, pumps and duration (Tables 7K / 7M), mains (Table 8), hydrant pressure 3.5–7 bar (cl. 5.1.1 f), sprinklers (cl. 5.1.3), gaseous suppression (cl. 5.1.6 / 5.1.9) |
| NBCS 2026 (SP 7:2026) Part E Sec 1 | National Building Construction Standards — Water supply | Per-capita demand, storage, fixture units and probable flow, pressures and zoning |
| NBC 2016 Part 4 | National Building Code — Fire and life safety | Occupant load (Table 5), exit width (Table 22), travel distance (Table 21), stair widths |
| CPHEEO Manual on Water Supply & Treatment (1999 / 2024) | Manual on Water Supply and Treatment | Per-capita demand, peak factors, distribution velocity and residual pressure |
| CPHEEO Manual on Water Supply and Treatment | Rapid gravity / pressure filter rates, chlorination doses | MGF / ACF filtration rate 10–20 m/h, chlorine dose 2–3 mg/L, ozone 1–3 g/m³ |
| IS 1172:1993 | Basic requirements for water supply, drainage and sanitation | Per-capita water requirement for storage sizing |
| IS 2065:1983 | Code of practice for water supply in buildings | Building water supply, risers, storage |
| IS 12469:1988 | Pumps for fire fighting systems | Fire pump performance envelope |
| IS 3844:1989 | Code of practice for installation and maintenance of internal fire hydrants and hose reels | Wet riser flow / pressure, landing valves, orifice plates |
| IS 15105:2002 | Design and installation of fixed automatic sprinkler fire extinguishing systems | Sprinkler hazard classes, density / area, K factors, durations |
| IS 3370:2021 (Parts 1–4) | Concrete structures for retaining aqueous liquids | RCC water tank walls / slabs, minimum thickness and crack control (quantities are indicative) |
| IS 6392:2003 | Steel pipe flanges | Puddle-flange / slip-on flange dimensions in the pipe-insert schedule |
Frequently asked
How do I use the Fire tank & pump room calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the fire tank & pump room follow?
It applies NBCS 2026 (SP 7:2026) Part F, NBCS 2026 (SP 7:2026) Part E Sec 1, NBC 2016 Part 4, CPHEEO Manual on Water Supply & Treatment (1999 / 2024), CPHEEO Manual on Water Supply and Treatment, IS 1172:1993 and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Tank capacity ≥ NBCS 2026 demand × duration (or NBC 2016 Table 7); Main pump flow and head per Table 7; Diesel standby equal to the main; Jockey flow ≥ leakage allowance; Suction NPSH available ≥ required.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/ugt/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a fire pump sizing calculator?
Yes. People also call it a fire tank capacity NBC 2016, a fire pump room design. It covers the same calculation under fire fighting design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.