All calculators
Plumbing / PHE · Live

Sewer & storm network

Manholes, pipes and buildings from the site DXF; population-based peak flows, Manning design for self-cleansing velocity and d/D, inverts and cover, SewerGEMS-style report, plan and L-section DXF, Excel and BOQ. Storm mode adds pipes, box drains and trapezoidal channels with IDF rainfall and outfall control.

CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part ANBCS 2026 (SP 7:2026) Part E Sec 2IS 4111 (Parts 1–5)IS 458:2003ASCE MOP No. 60 / WEF MOP FD-5 (2007)Ten-State Standards (2014)
What goes in, what comes out

You enter

  • Site DXF (manholes, pipes, buildings)
  • Population / discharge or rainfall, slopes, material
  • Outfall level

You get

  • Diameters, gradients, inverts, velocities
  • Plan + L-section DXF, Excel, BOQ
  • Report

What it does

From the site DXFManholes, pipes and buildings from layers; connectivity check with fixes.
Peak flowsPopulation × LPCD × peak factor, or rational-method storm flows.
Manning designDiameter and gradient for self-cleansing velocity and d/D at peak.
Inverts and coverCrown matching, drops at manholes, minimum cover, outfall control.
L-sectionsEvery line as a profile: Excel with charts, PDF, DXF sheet set in one click.
BOQPipes, manholes and excavation quantities.

Checks it performs

PASS / CHECKVelocity ≥ 0.6 m/s self-cleansing at design flow
PASS / CHECKVelocity ≤ 3 m/s
PASS / CHECKd/D ≤ 0.8 at peak
PASS / CHECKCover ≥ minimum under roads
PASS / CHECKEvery manhole drains to an outfall

Sample report

How to use it

  1. Import the site DXF (layers → manholes, pipes, buildings) or draw.
  2. Set population / discharge, slopes and pipe material.
  3. Design: diameters, gradients, velocities, invert levels; export plan, L-sections, Excel.

What you enter

  • Layout — manholes, pipes, buildings from DXF
  • Design — per-capita flow, peak factor, min velocity

What you get

  • Pipe schedule — size, slope, flow, velocity, d/D
  • Drawings — plan and longitudinal sections

Also searched as

sewer design calculator; storm water drain design; Manning formula sewer sizing; sewer network design software free; self cleansing velocity sewer; sewer L-section drawing. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part AEngineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes)Sewer network design rules (India)
NBCS 2026 (SP 7:2026) Part E Sec 2National Building Construction Standards — Drainage and sanitationSanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25)
IS 4111 (Parts 1–5)Code of practice for ancillary structures in sewerage systems — manholes, drop manholes, inverted siphonsManhole spacing / depth / drop manholes
IS 458:2003Precast concrete pipes (with and without reinforcement)RCC NP3 pipe classes and wall thickness
ASCE MOP No. 60 / WEF MOP FD-5 (2007)Gravity Sanitary Sewer Design and ConstructionInternational sewer design rules
Ten-State Standards (2014)Recommended Standards for Wastewater Facilities — ch. 30 sewersMinimum size / velocity / spacing / drop rules (US)
BS EN 752:2017Drain and sewer systems outside buildings — sewer system managementEuropean hydraulic design rules

Frequently asked

How do I use the Sewer & storm network calculator?

Import the site DXF (layers → manholes, pipes, buildings) or draw. Set population / discharge, slopes and pipe material. Design: diameters, gradients, velocities, invert levels; export plan, L-sections, Excel.

Which codes and standards does the sewer & storm network follow?

It applies CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A, NBCS 2026 (SP 7:2026) Part E Sec 2, IS 4111 (Parts 1–5), IS 458:2003, ASCE MOP No. 60 / WEF MOP FD-5 (2007), Ten-State Standards (2014) and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Velocity ≥ 0.6 m/s self-cleansing at design flow; Velocity ≤ 3 m/s; d/D ≤ 0.8 at peak; Cover ≥ minimum under roads; Every manhole drains to an outfall.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/sewer/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a sewer design calculator?

Yes. People also call it a storm water drain design, a Manning formula sewer sizing, a sewer network design software free. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related plumbing / phe calculators