Sewer & storm network
Manholes, pipes and buildings from the site DXF; population-based peak flows, Manning design for self-cleansing velocity and d/D, inverts and cover, SewerGEMS-style report, plan and L-section DXF, Excel and BOQ. Storm mode adds pipes, box drains and trapezoidal channels with IDF rainfall and outfall control.
You enter
- Site DXF (manholes, pipes, buildings)
- Population / discharge or rainfall, slopes, material
- Outfall level
You get
- Diameters, gradients, inverts, velocities
- Plan + L-section DXF, Excel, BOQ
- Report
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
How to use it
- Import the site DXF (layers → manholes, pipes, buildings) or draw.
- Set population / discharge, slopes and pipe material.
- Design: diameters, gradients, velocities, invert levels; export plan, L-sections, Excel.
What you enter
- Layout — manholes, pipes, buildings from DXF
- Design — per-capita flow, peak factor, min velocity
What you get
- Pipe schedule — size, slope, flow, velocity, d/D
- Drawings — plan and longitudinal sections
Also searched as
sewer design calculator; storm water drain design; Manning formula sewer sizing; sewer network design software free; self cleansing velocity sewer; sewer L-section drawing. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A | Engineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes) | Sewer network design rules (India) |
| NBCS 2026 (SP 7:2026) Part E Sec 2 | National Building Construction Standards — Drainage and sanitation | Sanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25) |
| IS 4111 (Parts 1–5) | Code of practice for ancillary structures in sewerage systems — manholes, drop manholes, inverted siphons | Manhole spacing / depth / drop manholes |
| IS 458:2003 | Precast concrete pipes (with and without reinforcement) | RCC NP3 pipe classes and wall thickness |
| ASCE MOP No. 60 / WEF MOP FD-5 (2007) | Gravity Sanitary Sewer Design and Construction | International sewer design rules |
| Ten-State Standards (2014) | Recommended Standards for Wastewater Facilities — ch. 30 sewers | Minimum size / velocity / spacing / drop rules (US) |
| BS EN 752:2017 | Drain and sewer systems outside buildings — sewer system management | European hydraulic design rules |
Frequently asked
How do I use the Sewer & storm network calculator?
Import the site DXF (layers → manholes, pipes, buildings) or draw. Set population / discharge, slopes and pipe material. Design: diameters, gradients, velocities, invert levels; export plan, L-sections, Excel.
Which codes and standards does the sewer & storm network follow?
It applies CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A, NBCS 2026 (SP 7:2026) Part E Sec 2, IS 4111 (Parts 1–5), IS 458:2003, ASCE MOP No. 60 / WEF MOP FD-5 (2007), Ten-State Standards (2014) and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Velocity ≥ 0.6 m/s self-cleansing at design flow; Velocity ≤ 3 m/s; d/D ≤ 0.8 at peak; Cover ≥ minimum under roads; Every manhole drains to an outfall.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/sewer/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a sewer design calculator?
Yes. People also call it a storm water drain design, a Manning formula sewer sizing, a sewer network design software free. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.