All calculators
Plumbing / PHE · Live

Water supply network

EPANET-style looped network from the site DXF: sources (OHT, sump and pump, municipal), building demands from population × LPCD, peak factor, main sizing for velocity and residual pressure, automatic pump duty with curve, internal riser and booster check per building, storage, with report, DXF and Excel.

NBCS 2026 (SP 7:2026) Part E Sec 1CPHEEO Manual on Water Supply & Treatment (1999 / 2024)IS 2065:1983IS 8329:2000AWWA M32IPC 2021
What goes in, what comes out

You enter

  • Site DXF or drawn network
  • Sources, population, LPCD, peak factor
  • Pipe material and design standard

You get

  • Pipe sizes, flows, pressures
  • Pump duty, storage
  • Report, DXF, Excel

What it does

From the site DXFNodes, pipes and buildings from layers; draw or edit on the plan.
DemandsPopulation × LPCD per building with the peak factor; fixture-unit option.
Looped solverHardy-Cross / gradient solution for flows and pressures.
Pump dutyHead and flow from the worst node; curve envelope.
Risers and boostersPer-building riser pressure and booster set check.
OutputsReport, plan DXF with pipe labels, Excel node and pipe tables.

Checks it performs

PASS / CHECKResidual pressure ≥ minimum at every node
PASS / CHECKVelocity within 0.6–2.5 m/s
PASS / CHECKHeadloss per 100 m ≤ the limit
PASS / CHECKPump duty within the curve
PASS / CHECKStorage ≥ the day’s demand fraction

Sample report

How to use it

  1. Draw or import nodes, pipes and buildings (demand by occupancy).
  2. Set the source (tank / pump / mains), pipe material and design standard.
  3. Run the pressurised-network solver; check residual pressures and velocities.
  4. Size storage and pumps; export report, DXF and Excel.

What you enter

  • Buildings — type, units, floors
  • Network — nodes with GL, pipes with length
  • Source — tank level, pump head

What you get

  • Hydraulics — flow, velocity, head loss, residual per node
  • Sizing — pipes, pump duty, storage

Also searched as

water supply network design; looped pipe network calculation Hardy Cross; water distribution network design software free; pump duty calculation for water supply; booster pump sizing for building; CPHEEO water supply design. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
NBCS 2026 (SP 7:2026) Part E Sec 1National Building Construction Standards — Water supplyPer-capita demand, storage, fixture units and probable flow, pressures and zoning
CPHEEO Manual on Water Supply & Treatment (1999 / 2024)Manual on Water Supply and TreatmentPer-capita demand, peak factors, distribution velocity and residual pressure
IS 2065:1983Code of practice for water supply in buildingsBuilding water supply, risers, storage
IS 8329:2000Centrifugally cast (spun) ductile iron pressure pipesDI pipe sizes, C value
AWWA M32Computer Modeling of Water Distribution SystemsNetwork analysis, velocity and pressure criteria
IPC 2021International Plumbing CodeBuilding water supply pressure and velocity (App. E); sanitary drainage fixture units, stacks, vents and building drains (ch. 7, 9)
BS EN 806 / BS 8558Specifications for installations inside buildings conveying waterBuilding water supply design (UK / international)
Ten-State Standards (2014)Recommended Standards for Wastewater Facilities — ch. 30 sewersMinimum size / velocity / spacing / drop rules (US)
DEWA Water Supply RegulationsDubai Electricity & Water Authority water regulationsGulf per-capita demand, storage, connection pressure
SBC 701:2018Saudi Plumbing CodeGulf building water supply (IPC basis)

Frequently asked

How do I use the Water supply network calculator?

Draw or import nodes, pipes and buildings (demand by occupancy). Set the source (tank / pump / mains), pipe material and design standard. Run the pressurised-network solver; check residual pressures and velocities.

Which codes and standards does the water supply network follow?

It applies NBCS 2026 (SP 7:2026) Part E Sec 1, CPHEEO Manual on Water Supply & Treatment (1999 / 2024), IS 2065:1983, IS 8329:2000, AWWA M32, IPC 2021 and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Residual pressure ≥ minimum at every node; Velocity within 0.6–2.5 m/s; Headloss per 100 m ≤ the limit; Pump duty within the curve; Storage ≥ the day’s demand fraction.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/water/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a water supply network design?

Yes. People also call it a looped pipe network calculation Hardy Cross, a water distribution network design software free, a pump duty calculation for water supply. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related plumbing / phe calculators