Water supply network
EPANET-style looped network from the site DXF: sources (OHT, sump and pump, municipal), building demands from population × LPCD, peak factor, main sizing for velocity and residual pressure, automatic pump duty with curve, internal riser and booster check per building, storage, with report, DXF and Excel.
You enter
- Site DXF or drawn network
- Sources, population, LPCD, peak factor
- Pipe material and design standard
You get
- Pipe sizes, flows, pressures
- Pump duty, storage
- Report, DXF, Excel
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
How to use it
- Draw or import nodes, pipes and buildings (demand by occupancy).
- Set the source (tank / pump / mains), pipe material and design standard.
- Run the pressurised-network solver; check residual pressures and velocities.
- Size storage and pumps; export report, DXF and Excel.
What you enter
- Buildings — type, units, floors
- Network — nodes with GL, pipes with length
- Source — tank level, pump head
What you get
- Hydraulics — flow, velocity, head loss, residual per node
- Sizing — pipes, pump duty, storage
Also searched as
water supply network design; looped pipe network calculation Hardy Cross; water distribution network design software free; pump duty calculation for water supply; booster pump sizing for building; CPHEEO water supply design. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| NBCS 2026 (SP 7:2026) Part E Sec 1 | National Building Construction Standards — Water supply | Per-capita demand, storage, fixture units and probable flow, pressures and zoning |
| CPHEEO Manual on Water Supply & Treatment (1999 / 2024) | Manual on Water Supply and Treatment | Per-capita demand, peak factors, distribution velocity and residual pressure |
| IS 2065:1983 | Code of practice for water supply in buildings | Building water supply, risers, storage |
| IS 8329:2000 | Centrifugally cast (spun) ductile iron pressure pipes | DI pipe sizes, C value |
| AWWA M32 | Computer Modeling of Water Distribution Systems | Network analysis, velocity and pressure criteria |
| IPC 2021 | International Plumbing Code | Building water supply pressure and velocity (App. E); sanitary drainage fixture units, stacks, vents and building drains (ch. 7, 9) |
| BS EN 806 / BS 8558 | Specifications for installations inside buildings conveying water | Building water supply design (UK / international) |
| Ten-State Standards (2014) | Recommended Standards for Wastewater Facilities — ch. 30 sewers | Minimum size / velocity / spacing / drop rules (US) |
| DEWA Water Supply Regulations | Dubai Electricity & Water Authority water regulations | Gulf per-capita demand, storage, connection pressure |
| SBC 701:2018 | Saudi Plumbing Code | Gulf building water supply (IPC basis) |
Frequently asked
How do I use the Water supply network calculator?
Draw or import nodes, pipes and buildings (demand by occupancy). Set the source (tank / pump / mains), pipe material and design standard. Run the pressurised-network solver; check residual pressures and velocities.
Which codes and standards does the water supply network follow?
It applies NBCS 2026 (SP 7:2026) Part E Sec 1, CPHEEO Manual on Water Supply & Treatment (1999 / 2024), IS 2065:1983, IS 8329:2000, AWWA M32, IPC 2021 and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Residual pressure ≥ minimum at every node; Velocity within 0.6–2.5 m/s; Headloss per 100 m ≤ the limit; Pump duty within the curve; Storage ≥ the day’s demand fraction.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/water/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a water supply network design?
Yes. People also call it a looped pipe network calculation Hardy Cross, a water distribution network design software free, a pump duty calculation for water supply. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.