Heat load — E20 & HAP 6

Independent room table (typed, pasted or uploaded from the input Excel, IP or SI) or the building model: Carrier E20 (ETD tables) or ASHRAE sol-air CLTD with clear-sky solar, ISHRAE city weather, ASHRAE 62.1 / 90.1 or ECBC defaults per room type, peak-hour search with block load and diversity, ADP / SHR / CFM. Full E20 workbook with live formulas, HAP v6 space-grid sheet and gbXML for HAP 6.2 Import gbXML, report and plan DXF.

ASHRAE Handbook — Fundamentals 2021NBCS 2026 (SP 7:2026) Part D Sec 3ASHRAE 62.1-2022ASHRAE 90.1-2019ECBC 2017 (BEE)Carrier System Design Manual Part 1
What goes in, what comes out

You enter

  • Building model (or rooms typed in)
  • City, design conditions, internal loads per room type
  • Method: E20 or ASHRAE

You get

  • Room and block loads, peak hour, TR
  • E20 workbook, HAP 6 space sheet
  • Report and plan DXF

What it does

From the building modelRooms, walls by orientation, glass and storeys come from the floor-plan model.
E20 or CLTDCarrier ETD tables or ASHRAE sol-air CLTD with clear-sky solar for the city.
Peak-hour searchEvery hour of the design day per room and for the block, with diversity.
Defaults per room typePeople, lighting, equipment and ventilation from ASHRAE 62.1 / 90.1 or ECBC.
ADP, SHR, CFMCoil selection numbers per room and per AHU.
E20 workbookEvery sheet with live formulas, plus the HAP 6 space import.

Checks it performs

PASS / CHECKVentilation ≥ ASHRAE 62.1 / ECBC minimum per room
PASS / CHECKSupply air ≥ minimum air changes for the room type
PASS / CHECKCoil ADP within the achievable range
PASS / CHECKBlock load < Σ room peaks (diversity applied)
PASS / CHECKEnvelope U-values within ECBC when ECBC is selected

Sample report

How to use it

  1. Start a room table (type, paste or upload the input Excel) — or open the heat load from a building model (rooms, walls, glass, orientation).
  2. Set the city, design conditions and internal loads per room.
  3. Compute the peak-hour cooling load (Carrier ETD / ASHRAE CLTD); export the E20 workbook, the HAP v6 space grid or the gbXML for HAP 6.2.

What you enter

  • Rooms — area, height, exposures, glass, occupancy, lighting, equipment
  • Conditions — city, inside / outside design

What you get

  • Loads — sensible / latent per room, TR
  • E20 workbook — live formulas
  • Input Excel — download / fill / upload rooms and design basis
  • HAP v6 — space-grid sheet; gbXML (building model) for Project → Import gbXML

Also searched as

heat load calculation; HVAC heat load calculator online; cooling load calculation E20 form; heat load calculation excel sheet; gbXML export for HAP; CLTD method cooling load. The same calculation, the same clauses — one tool for hvac design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
ASHRAE Handbook — Fundamentals 2021Psychrometrics (ch. 1), climatic design (ch. 14), cooling/heating load (ch. 18), solar (1997 ch. 29)Load calculation method, solar heat gain, sol-air temperature
NBCS 2026 (SP 7:2026) Part D Sec 3National Building Construction Standards — Air conditioning, heating and mechanical ventilationDesign conditions (Table 3), ventilation (Table 7), duct velocities (Table 18), clean rooms (Table 31), automation
ASHRAE 62.1-2022Ventilation for Acceptable Indoor Air QualityOccupant density and outdoor air rates per space type
ASHRAE 90.1-2019Energy Standard for BuildingsLighting power density by space type
ECBC 2017 (BEE)Energy Conservation Building Code — superseded by ECSBC 2024; still enforced where a State has not yet notified ECSBC 2024Envelope U / SHGC and lighting power density (India option)
Carrier System Design Manual Part 1Load Estimating (E20 form; Tables 15, 19, 20, 20A, 48, 61)Equivalent temperature differences, people gains, bypass factor
ISHRAE Handbook / weather dataIndian climatic design conditionsCity design DB / WB, daily range

Frequently asked

How do I use the Heat load — E20 & HAP 6 calculator?

Start a room table (type, paste or upload the input Excel) — or open the heat load from a building model (rooms, walls, glass, orientation). Set the city, design conditions and internal loads per room. Compute the peak-hour cooling load (Carrier ETD / ASHRAE CLTD); export the E20 workbook, the HAP v6 space grid or the gbXML for HAP 6.2.

Which codes and standards does the heat load follow?

It applies ASHRAE Handbook — Fundamentals 2021, NBCS 2026 (SP 7:2026) Part D Sec 3, ASHRAE 62.1-2022, ASHRAE 90.1-2019, ECBC 2017 (BEE), Carrier System Design Manual Part 1 and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Ventilation ≥ ASHRAE 62.1 / ECBC minimum per room; Supply air ≥ minimum air changes for the room type; Coil ADP within the achievable range; Block load < Σ room peaks (diversity applied); Envelope U-values within ECBC when ECBC is selected.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/hvac/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a heat load calculation?

Yes. People also call it a HVAC heat load calculator online, a cooling load calculation E20 form, a heat load calculation excel sheet. It covers the same calculation under hvac design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related hvac calculators