Exhaust fan by air changes
Room volume × air changes per hour → exhaust airflow, number and sweep of wall / window exhaust fans after the derating for louvres and short ducts, and the free area of the make-up air opening.
You enter
- Room size, use or air changes
- Derating, make-up velocity
You get
- Airflow, fans, sweep
- Make-up opening
- Report
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
exhaust fan size calculator; air changes per hour calculator; toilet exhaust fan size. The same calculation, the same clauses — one tool for hvac design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| ASHRAE 62.1-2022 | Ventilation for Acceptable Indoor Air Quality | Occupant density and outdoor air rates per space type |
| NBC 2016 Part 8 Section 3 | Air-conditioning, heating and mechanical ventilation | Design conditions, ventilation rates, ducting and safety (India) |
Frequently asked
How do I use the Exhaust fan by air changes calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the exhaust fan by air changes follow?
It applies ASHRAE 62.1-2022, NBC 2016 Part 8 Section 3. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Fans deliver the airflow after derating.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/exhaustfan/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a exhaust fan size calculator?
Yes. People also call it a air changes per hour calculator, a toilet exhaust fan size. It covers the same calculation under hvac design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.