All calculators
HVAC · Live

Psychrometric processes

State points, mixing, sensible heating and cooling, the cooling coil with ADP and bypass factor, humidification and energy recovery. Properties in IP with SI, loads in Btu/h, kW and TR, condensate.

ASHRAE Handbook — Fundamentals 2021Carrier System Design Manual Part 1ISHRAE Handbook / weather dataNBCS 2026 (SP 7:2026) Part D Sec 3
What goes in, what comes out

You enter

  • Altitude, entering states, air flow
  • Process type and targets

You get

  • State table, process loads (kW / TR / Btu/h)
  • Condensate, coil ADP and BF
  • Report

What it does

State pointsAny two of DB, WB, RH, dew point, humidity ratio, enthalpy.
MixingReturn and outdoor air by mass ratio.
Cooling coilADP, bypass factor, contact factor, leaving state, sensible and latent load.
Heating and humidificationSensible heating, steam and adiabatic humidification.
Energy recoverySensible and enthalpy wheel effectiveness.
Condensatekg/h from the humidity ratio change and the air mass flow.

Checks it performs

PASS / CHECKLeaving state on or above saturation
PASS / CHECKADP within the coil’s achievable range
PASS / CHECKSupply temperature difference within the diffuser limit
PASS / CHECKMixed state within the coil entering limits
PASS / CHECKHumidification within the steam capacity

Sample report

Also searched as

psychrometric calculator online; psychrometric chart calculator; mixing of air streams calculation; coil ADP bypass factor calculation; dew point and enthalpy calculator; sensible and latent heat calculation. The same calculation, the same clauses — one tool for hvac design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
ASHRAE Handbook — Fundamentals 2021Psychrometrics (ch. 1), climatic design (ch. 14), cooling/heating load (ch. 18), solar (1997 ch. 29)Load calculation method, solar heat gain, sol-air temperature
Carrier System Design Manual Part 1Load Estimating (E20 form; Tables 15, 19, 20, 20A, 48, 61)Equivalent temperature differences, people gains, bypass factor
ISHRAE Handbook / weather dataIndian climatic design conditionsCity design DB / WB, daily range
NBCS 2026 (SP 7:2026) Part D Sec 3National Building Construction Standards — Air conditioning, heating and mechanical ventilationDesign conditions (Table 3), ventilation (Table 7), duct velocities (Table 18), clean rooms (Table 31), automation

Frequently asked

How do I use the Psychrometric processes calculator?

Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

Which codes and standards does the psychrometric processes follow?

It applies ASHRAE Handbook — Fundamentals 2021, Carrier System Design Manual Part 1, ISHRAE Handbook / weather data, NBCS 2026 (SP 7:2026) Part D Sec 3. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Leaving state on or above saturation; ADP within the coil’s achievable range; Supply temperature difference within the diffuser limit; Mixed state within the coil entering limits; Humidification within the steam capacity.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/psychro/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a psychrometric calculator online?

Yes. People also call it a psychrometric chart calculator, a mixing of air streams calculation, a coil ADP bypass factor calculation. It covers the same calculation under hvac design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related hvac calculators