All calculators
HVAC · Live

Insulation & condensate

Dew point, minimum and selected insulation for pipes and flat surfaces, surface-temperature check, heat gain per metre, condensate kg/h from TR and SHR, and the condensate drain pipe size.

IS 14164:2008ASHRAE Handbook — Fundamentals 2021ISHRAE Handbook / weather dataNBCS 2026 (SP 7:2026) Part D Sec 3NBCS 2026 (SP 7:2026) Part F
What goes in, what comes out

You enter

  • Ambient DB / RH, wind, surface emissivity
  • Fluid temperature, pipe sizes, material
  • TR and SHR for condensate

You get

  • Thickness table per size
  • Heat gain, surface temperature
  • Condensate and drain size; report

What it does

Dew pointFrom ambient DB and RH; the surface must stay above it.
Minimum thicknessPipe (log) and flat-surface conduction against the outside film coefficient.
Selected thicknessNearest standard thickness and the resulting surface temperature.
Heat gainW/m or W/m² for the chilled-water and duct losses.
Condensatekg/h from TR and SHR; drain size and slope.
ReportTable per pipe size with the clause.

Checks it performs

PASS / CHECKSurface temperature ≥ dew point + margin
PASS / CHECKThickness ≥ IS 14164 / ASHRAE minimum
PASS / CHECKHeat gain ≤ the design limit per metre
PASS / CHECKDrain pipe size ≥ condensate flow
PASS / CHECKDrain slope ≥ 1 in 100

Sample report

Also searched as

insulation thickness calculator for pipe; condensation prevention insulation thickness; chilled water pipe insulation thickness; duct insulation thickness calculation; condensate drain pipe sizing; dew point insulation calculator. The same calculation, the same clauses — one tool for hvac design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
IS 14164:2008Industrial application and finishing of thermal insulation materialsInsulation thickness practice, condensation control
ASHRAE Handbook — Fundamentals 2021Psychrometrics (ch. 1), climatic design (ch. 14), cooling/heating load (ch. 18), solar (1997 ch. 29)Load calculation method, solar heat gain, sol-air temperature
ISHRAE Handbook / weather dataIndian climatic design conditionsCity design DB / WB, daily range
NBCS 2026 (SP 7:2026) Part D Sec 3National Building Construction Standards — Air conditioning, heating and mechanical ventilationDesign conditions (Table 3), ventilation (Table 7), duct velocities (Table 18), clean rooms (Table 31), automation
NBCS 2026 (SP 7:2026) Part FNational Building Construction Standards — Fire and life safetyMeans of egress (Tables 2–4, cl. 4.4.2), staircase / lobby / lift-well pressurisation (cl. 4.4.2.5, Table 5), emergency lighting (cl. 3.5.6), fire-fighting installations by occupancy (Tables 7A–7J), demand, pumps and duration (Tables 7K / 7M), mains (Table 8), hydrant pressure 3.5–7 bar (cl. 5.1.1 f), sprinklers (cl. 5.1.3), gaseous suppression (cl. 5.1.6 / 5.1.9)

Frequently asked

How do I use the Insulation & condensate calculator?

Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

Which codes and standards does the insulation & condensate follow?

It applies IS 14164:2008, ASHRAE Handbook — Fundamentals 2021, ISHRAE Handbook / weather data, NBCS 2026 (SP 7:2026) Part D Sec 3, NBCS 2026 (SP 7:2026) Part F. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Surface temperature ≥ dew point + margin; Thickness ≥ IS 14164 / ASHRAE minimum; Heat gain ≤ the design limit per metre; Drain pipe size ≥ condensate flow; Drain slope ≥ 1 in 100.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/insulation/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a insulation thickness calculator for pipe?

Yes. People also call it a condensation prevention insulation thickness, a chilled water pipe insulation thickness, a duct insulation thickness calculation. It covers the same calculation under hvac design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.