All calculators
Building model · Live

Design & tender package

The deliverable itself: from a project hub, a numbered design and tender package — cover, revision history, contents, drawing register, the design-basis summary (each tool's key results and code checks), the technical specification, the BOQ roll-up and each tool's full report as an appendix — as a print-ready document, a server PDF with page numbers where a renderer is installed, and a ZIP with every DXF, Excel and Word file, re-issued revision by revision.

CPWD General Specifications for Electrical Works (Part I Internal, Part IV Substation)NBCS 2026 (SP 7:2026) Part D Sec 2NBCS 2026 (SP 7:2026) Part FNBCS 2026 (SP 7:2026) Part E Sec 1IS 732:2019IEC 60364-1

What it does

Checks it performs

Sample report

How to use it

  1. Open it from the project hub (Package button): every linked tool becomes a section, with its DXFs numbered in the drawing register (E-, F-, M-, P-).
  2. Fill the cover and revision block — client, location, document reference, revision, status, prepared / checked / approved; untick any section to leave it out of this issue.
  3. Link a specification (Specification button on the hub) so it is included; the BOQ roll-up comes from the hub automatically.
  4. Preview / Print for the document, PDF for the server-rendered file with page numbers, ZIP for everything — package, specification DOCX and compliance sheet, BOQ, every report, Excel and DXF with a manifest. New revision closes the issue into the history.

What you enter

  • Project hub — linked tools, their results and checks
  • Cover & revision — client, location, reference, rev, status, signatures
  • Specification — the spec project linked to the hub

What you get

  • Document — cover → appendices, print-ready
  • PDF — with page numbers (renderer required)
  • ZIP — all DXF / Excel / Word / HTML with manifest.json

Also searched as

design and tender package; MEP design document package; drawing register generator; tender document compilation MEP; design basis report generator. The same calculation, the same clauses — one tool for building model design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
CPWD General Specifications for Electrical Works (Part I Internal, Part IV Substation)CPWD specificationsVoltage-drop cascade limits, cable/wiring practice, panel and metering requirements
NBCS 2026 (SP 7:2026) Part D Sec 2National Building Construction Standards — Electrical and allied installationsLoad assessment and diversity, circuits, cables (4-core), earthing, lightning protection, standby supply for fire & life-safety loads
NBCS 2026 (SP 7:2026) Part FNational Building Construction Standards — Fire and life safetyMeans of egress (Tables 2–4, cl. 4.4.2), staircase / lobby / lift-well pressurisation (cl. 4.4.2.5, Table 5), emergency lighting (cl. 3.5.6), fire-fighting installations by occupancy (Tables 7A–7J), demand, pumps and duration (Tables 7K / 7M), mains (Table 8), hydrant pressure 3.5–7 bar (cl. 5.1.1 f), sprinklers (cl. 5.1.3), gaseous suppression (cl. 5.1.6 / 5.1.9)
NBCS 2026 (SP 7:2026) Part E Sec 1National Building Construction Standards — Water supplyPer-capita demand, storage, fixture units and probable flow, pressures and zoning
IS 732:2019Code of practice for electrical wiring installationsVoltage-drop limits, cable selection, protection coordination (adopts IEC 60364)
IEC 60364-1Low-voltage electrical installations — fundamental principles, assessment of general characteristicsMaximum demand and diversity
NFPA 13:2022Standard for the Installation of Sprinkler SystemsDesign densities, hydraulic calculation method, equivalent lengths
ASHRAE 90.1-2019Energy Standard for Buildings Except Low-Rise Residential BuildingsPrescriptive envelope, HVAC efficiency, lighting power, power and other equipment

Frequently asked

How do I use the Design & tender package calculator?

Open it from the project hub (Package button): every linked tool becomes a section, with its DXFs numbered in the drawing register (E-, F-, M-, P-). Fill the cover and revision block — client, location, document reference, revision, status, prepared / checked / approved; untick any section to leave it out of this issue. Link a specification (Specification button on the hub) so it is included; the BOQ roll-up comes from the hub automatically.

Which codes and standards does the design & tender package follow?

It applies CPWD General Specifications for Electrical Works (Part I Internal, Part IV Substation), NBCS 2026 (SP 7:2026) Part D Sec 2, NBCS 2026 (SP 7:2026) Part F, NBCS 2026 (SP 7:2026) Part E Sec 1, IS 732:2019, IEC 60364-1 and others. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/package/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a design and tender package?

Yes. People also call it a MEP design document package, a drawing register generator, a tender document compilation MEP. It covers the same calculation under building model design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related building model calculators