Energy code compliance — ECSBC 2024 / ASHRAE 90.1
The energy-code check the client asks for at concept stage — ECSBC 2024 by default (ECBC 2017 option, ASHRAE 90.1 international): pick the city (climate zone follows), the level and the building type, pull the WWR from the building model, the installed LPD from the lighting design, the plug loads and the peak cooling from the load and heat-load tools, type the envelope U-values and the plant efficiencies — and read every prescriptive requirement against the proposed value with its clause, edit a requirement where the current edition differs, and see the EPI estimate against the benchmark.
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
How to use it
- Set the regime and edition (ECSBC 2024 default, ECBC 2017 option / ASHRAE 90.1), the level (ECSBC / ECSBC+ / Super ECSBC), the city (climate zone follows) and the building type; pull the area and WWR from the building model.
- Type the proposed envelope (wall / roof / glass U, SHGC, VLT, SRI, skylights), pull the installed LPD from the lighting design, list the chillers, unitary units, fan systems and UPS with their efficiencies, tick the controls and measures provided.
- Read the checklist: every prescriptive requirement with the code value, the proposed value, PASS / FAIL and the clause; edit a requirement where your code edition differs (flagged in the report).
- Check the EPI estimate against the benchmark; export the checklist Excel and the compliance report.
What you enter
- Basis — regime, level, city / zone, building type, area
- Envelope — WWR, U-values, SHGC, VLT, SRI, skylights, daylighting
- Lighting — LPD, spaces, controls
- HVAC — chillers, unitary, fans, VFDs, economizer, insulation, controls
- Electrical — transformer, motors, PF, UPS, metering, renewable, SWH, lifts
What you get
- Checklist — requirement, code value, proposed, result, clause
- EPI — kWh/m²/yr by component vs benchmark
- Report / Excel — submission-style compliance tables
Also searched as
ECBC compliance calculator; ECBC 2017 checklist; ASHRAE 90.1 compliance check; energy code compliance for building; ECBC prescriptive compliance; EPI calculation ECBC. The same calculation, the same clauses — one tool for building model design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| ECBC 2017 (BEE) | Energy Conservation Building Code — superseded by ECSBC 2024; still enforced where a State has not yet notified ECSBC 2024 | Envelope U / SHGC and lighting power density (India option) |
| ECSBC 2024 (BEE) | Energy Conservation and Sustainable Building Code 2024 — commercial and office buildings (Bureau of Energy Efficiency); supersedes ECBC 2017 | Energy and sustainability: building envelope (Ch 5), comfort systems and controls (Ch 6), lighting and controls (Ch 7), electrical and renewable energy (Ch 8), water management (Ch 9), waste management (Ch 10), indoor environment quality (Ch 11); tiers ECSBC / ECSBC+ / Super ECSBC; applies to connected load ≥ 100 kW or contract demand ≥ 120 kVA once notified by the State |
| ASHRAE 90.1-2019 | Energy Standard for Buildings Except Low-Rise Residential Buildings | Prescriptive envelope, HVAC efficiency, lighting power, power and other equipment |
| NBCS 2026 (SP 7:2026) Part D Sec 1 | National Building Construction Standards — Lighting and natural ventilation | Illuminance and lighting quality by room (Table 6), daylight, natural ventilation |
| NBCS 2026 (SP 7:2026) Part D Sec 3 | National Building Construction Standards — Air conditioning, heating and mechanical ventilation | Design conditions (Table 3), ventilation (Table 7), duct velocities (Table 18), clean rooms (Table 31), automation |
Frequently asked
How do I use the Energy code compliance — ECSBC 2024 / ASHRAE 90.1 calculator?
Set the regime and edition (ECSBC 2024 default, ECBC 2017 option / ASHRAE 90.1), the level (ECSBC / ECSBC+ / Super ECSBC), the city (climate zone follows) and the building type; pull the area and WWR from the building model. Type the proposed envelope (wall / roof / glass U, SHGC, VLT, SRI, skylights), pull the installed LPD from the lighting design, list the chillers, unitary units, fan systems and UPS with their efficiencies, tick the controls and measures provided. Read the checklist: every prescriptive requirement with the code value, the proposed value, PASS / FAIL and the clause; edit a requirement where your code edition differs (flagged in the report).
Which codes and standards does the energy code compliance follow?
It applies ECBC 2017 (BEE), ECSBC 2024 (BEE), ASHRAE 90.1-2019, NBCS 2026 (SP 7:2026) Part D Sec 1, NBCS 2026 (SP 7:2026) Part D Sec 3. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/ecbc/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a ECBC compliance calculator?
Yes. People also call it a ECBC 2017 checklist, a ASHRAE 90.1 compliance check, a energy code compliance for building. It covers the same calculation under building model design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.