Swimming pool plant
Turnover and bather load, sand filters and backwash, pumps and pipe sizes, balance tank, evaporation and heat loss to the heater or heat pump, dosing, UV, make-up; the plant room laid out with pipes, DXF and 3D.
You enter
- Pool dimensions, type, bathers
- Filtration, heating and treatment choices
- Plant-room space
You get
- Filters, pumps, pipes, heater, dosing
- Plant-room DXF and 3D
- Report
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
swimming pool filtration calculation; pool pump sizing calculator; swimming pool turnover rate; pool filter size calculation; pool heating calculation; swimming pool plant room design. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| NBCS 2026 (SP 7:2026) Part E Sec 1 | National Building Construction Standards — Water supply | Per-capita demand, storage, fixture units and probable flow, pressures and zoning |
| PWTAG Code of Practice (2020) / Swimming Pool Water (2017) | Pool Water Treatment Advisory Group — design and operation of swimming pool water treatment | Turnover periods, filtration rates, bather load, balance tank, disinfection residuals, secondary UV / ozone |
| IS 3328:1993 | Quality tolerances for water for swimming pools | Water quality limits, chlorine residual, pH, turnover and circulation guidance |
| ASHRAE Handbook — HVAC Applications ch. 51 | Service water heating | Hot-water demand, storage and recovery |
| IS 1172:1993 | Basic requirements for water supply, drainage and sanitation | Per-capita water requirement for storage sizing |
| CPHEEO Manual on Water Supply & Treatment (1999 / 2024) | Manual on Water Supply and Treatment | Per-capita demand, peak factors, distribution velocity and residual pressure |
Frequently asked
How do I use the Swimming pool plant calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the swimming pool plant follow?
It applies NBCS 2026 (SP 7:2026) Part E Sec 1, PWTAG Code of Practice (2020) / Swimming Pool Water (2017), IS 3328:1993, ASHRAE Handbook — HVAC Applications ch. 51, IS 1172:1993, CPHEEO Manual on Water Supply & Treatment (1999 / 2024). Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Filtration rate ≤ 25 m/h (PWTAG); Turnover period ≤ the pool-type limit; Backwash storage ≥ one filter backwash; Pipe velocity ≤ 2 m/s suction, 2.5 m/s delivery; Heater recovers the losses at design ambient.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/pool/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a swimming pool filtration calculation?
Yes. People also call it a pool pump sizing calculator, a swimming pool turnover rate, a pool filter size calculation. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.