Rainwater harvesting
Annual harvest and first flush, storage tank, downpipe DN and gutter for the design storm, storm runoff and the recharge pit capacity and count.
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
rainwater harvesting calculator; recharge pit calculation; rainwater harvesting potential calculation; rainwater storage tank size; first flush calculation; rainwater harvesting design India. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| NBCS 2026 (SP 7:2026) Part E Sec 2 | National Building Construction Standards — Drainage and sanitation | Sanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25) |
| IS 15797:2008 | Roof-top rainwater harvesting — guidelines | Rainwater harvesting design |
| BS EN 12056-3 | Gravity drainage systems — roof drainage | Gutter and downpipe capacities |
| CGWB Manual on Artificial Recharge of Ground Water (2007) | Central Ground Water Board manual | Recharge pit / trench sizing |
| CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A | Engineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes) | Sewer network design rules (India) |
Frequently asked
How do I use the Rainwater harvesting calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the rainwater harvesting follow?
It applies NBCS 2026 (SP 7:2026) Part E Sec 2, IS 15797:2008, BS EN 12056-3, CGWB Manual on Artificial Recharge of Ground Water (2007), CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: First flush ≥ 1–2 mm of roof area; Storage ≤ available dry-period demand; Downpipe capacity ≥ roof flow; Recharge capacity ≥ runoff for the storm; Pit depth above the water table.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/rainwater/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a rainwater harvesting calculator?
Yes. People also call it a recharge pit calculation, a rainwater harvesting potential calculation, a rainwater storage tank size. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.