All calculators
Plumbing / PHE · Live

Rainwater harvesting

Annual harvest and first flush, storage tank, downpipe DN and gutter for the design storm, storm runoff and the recharge pit capacity and count.

NBCS 2026 (SP 7:2026) Part E Sec 2IS 15797:2008BS EN 12056-3CGWB Manual on Artificial Recharge of Ground Water (2007)CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A

What it does

HarvestAnnual rainfall × area × runoff coefficient minus first flush.
StorageTank for the dry-spell demand or the design storm.
Downpipes and guttersDN and gutter size for the design intensity.
RunoffRational-method storm runoff for the plot.
Recharge pitsCapacity from the percolation rate; pit count.
ReportWith IS 15797 / CGWB references.

Checks it performs

PASS / CHECKFirst flush ≥ 1–2 mm of roof area
PASS / CHECKStorage ≤ available dry-period demand
PASS / CHECKDownpipe capacity ≥ roof flow
PASS / CHECKRecharge capacity ≥ runoff for the storm
PASS / CHECKPit depth above the water table

Sample report

Also searched as

rainwater harvesting calculator; recharge pit calculation; rainwater harvesting potential calculation; rainwater storage tank size; first flush calculation; rainwater harvesting design India. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
NBCS 2026 (SP 7:2026) Part E Sec 2National Building Construction Standards — Drainage and sanitationSanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25)
IS 15797:2008Roof-top rainwater harvesting — guidelinesRainwater harvesting design
BS EN 12056-3Gravity drainage systems — roof drainageGutter and downpipe capacities
CGWB Manual on Artificial Recharge of Ground Water (2007)Central Ground Water Board manualRecharge pit / trench sizing
CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part AEngineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes)Sewer network design rules (India)

Frequently asked

How do I use the Rainwater harvesting calculator?

Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

Which codes and standards does the rainwater harvesting follow?

It applies NBCS 2026 (SP 7:2026) Part E Sec 2, IS 15797:2008, BS EN 12056-3, CGWB Manual on Artificial Recharge of Ground Water (2007), CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: First flush ≥ 1–2 mm of roof area; Storage ≤ available dry-period demand; Downpipe capacity ≥ roof flow; Recharge capacity ≥ runoff for the storm; Pit depth above the water table.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/rainwater/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a rainwater harvesting calculator?

Yes. People also call it a recharge pit calculation, a rainwater harvesting potential calculation, a rainwater storage tank size. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related plumbing / phe calculators