Septic tank & soak pit
Septic tank volume and L × B × depth with the IS 2470 table, soak pit or trench size from the percolation rate, and the grease-trap capacity.
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
septic tank design calculator IS 2470; septic tank size calculation; soak pit design calculation; grease trap sizing; septic tank dimensions for 10 users; soak pit size calculator. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| IS 2470 (Parts 1 & 2):1985 | Code of practice for installation of septic tanks | Septic tank capacity, soak pit and dispersion trench |
| NBCS 2026 (SP 7:2026) Part E Sec 2 | National Building Construction Standards — Drainage and sanitation | Sanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25) |
| CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A | Engineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes) | Sewer network design rules (India) |
Frequently asked
How do I use the Septic tank & soak pit calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the septic tank & soak pit follow?
It applies IS 2470 (Parts 1 & 2):1985, NBCS 2026 (SP 7:2026) Part E Sec 2, CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Retention ≥ 24 h; Sludge storage for the cleaning interval; Soak pit area ≥ flow / percolation rate; Pit bottom ≥ 2 m above the water table; Grease trap retention ≥ 30 min.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/septic/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a septic tank design calculator IS 2470?
Yes. People also call it a septic tank size calculation, a soak pit design calculation, a grease trap sizing. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.