All calculators
Plumbing / PHE · Live

Septic tank & soak pit

Septic tank volume and L × B × depth with the IS 2470 table, soak pit or trench size from the percolation rate, and the grease-trap capacity.

IS 2470 (Parts 1 & 2):1985NBCS 2026 (SP 7:2026) Part E Sec 2CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A

What it does

Tank volumeSewage plus sludge storage for the users and the cleaning interval.
IS 2470 tableL × B × depth from the standard table, with baffles.
Soak pitArea from the percolation rate; pit or trench.
Grease trapCapacity for the kitchen flow and retention.
DimensionsFreeboard, inlet / outlet levels.
ReportWith the IS 2470 clauses.

Checks it performs

PASS / CHECKRetention ≥ 24 h
PASS / CHECKSludge storage for the cleaning interval
PASS / CHECKSoak pit area ≥ flow / percolation rate
PASS / CHECKPit bottom ≥ 2 m above the water table
PASS / CHECKGrease trap retention ≥ 30 min

Sample report

Also searched as

septic tank design calculator IS 2470; septic tank size calculation; soak pit design calculation; grease trap sizing; septic tank dimensions for 10 users; soak pit size calculator. The same calculation, the same clauses — one tool for plumbing / phe design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
IS 2470 (Parts 1 & 2):1985Code of practice for installation of septic tanksSeptic tank capacity, soak pit and dispersion trench
NBCS 2026 (SP 7:2026) Part E Sec 2National Building Construction Standards — Drainage and sanitationSanitary fixtures by occupancy (Tables 1–17), DFU, stacks, vents, building drains, rainwater pipes (Table 25)
CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part AEngineering — design of sewers (flows, peak factors, Manning, velocities, d/D, cover, manholes)Sewer network design rules (India)

Frequently asked

How do I use the Septic tank & soak pit calculator?

Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

Which codes and standards does the septic tank & soak pit follow?

It applies IS 2470 (Parts 1 & 2):1985, NBCS 2026 (SP 7:2026) Part E Sec 2, CPHEEO Manual on Sewerage and Sewage Treatment Systems (2013), Part A. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: Retention ≥ 24 h; Sludge storage for the cleaning interval; Soak pit area ≥ flow / percolation rate; Pit bottom ≥ 2 m above the water table; Grease trap retention ≥ 30 min.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/septic/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a septic tank design calculator IS 2470?

Yes. People also call it a septic tank size calculation, a soak pit design calculation, a grease trap sizing. It covers the same calculation under plumbing / phe design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.

Related plumbing / phe calculators