Line regulation & technical losses
Voltage drop, regulation and I²R loss of an 11 kV / 33 kV / LT line with ACSR conductor data or your own R and X, load lumped at the end or spread along the line, and the annual energy loss with the loss load factor.
You enter
- Voltage, length, conductor
- Peak load, pf, load factor
- Allowed drop, tariff
You get
- Current, drop, regulation
- Peak and annual loss
- Report
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
line voltage regulation calculation; technical losses distribution line; 11 kV line voltage drop calculator; ACSR line losses. The same calculation, the same clauses — one tool for electrical design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| IS 398 (Part 2) | Aluminium conductors for overhead transmission purposes — aluminium conductors, galvanised steel-reinforced (ACSR) | ACSR conductor resistance for line regulation and losses |
| CEA (Measures relating to Safety and Electric Supply) Regulations, 2023 | Central Electricity Authority safety regulations | Statutory safety requirements for installations |
Frequently asked
How do I use the Line regulation & technical losses calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the line regulation & technical losses follow?
It applies IS 398 (Part 2), CEA (Measures relating to Safety and Electric Supply) Regulations, 2023. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Voltage drop within the allowed limit.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/lineloss/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a line voltage regulation calculation?
Yes. People also call it a technical losses distribution line, a 11 kV line voltage drop calculator, a ACSR line losses. It covers the same calculation under electrical design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.