Transformer losses & payback
Transformer efficiency at any load from the no-load and load losses, the load of maximum efficiency, regulation from %Z, annual loss energy with the load profile, total owning cost with A and B factors, and the payback of a more efficient transformer.
You enter
- kVA, no-load and load losses, %Z, price
- Load, pf, load factor
- Tariff, discount rate, years
You get
- Efficiency, regulation
- Annual loss energy and cost
- TOC and payback
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
transformer losses calculation; transformer efficiency calculator; transformer total owning cost; transformer regulation calculation. The same calculation, the same clauses — one tool for electrical design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| IS 1180 (Part 1):2014 | Outdoor type oil-immersed distribution transformers up to 2500 kVA, 33 kV | Typical impedance (%Z) by rating |
| IEC 60076 (series) | Power transformers | Impedance, ratings and losses used for the fault study source model |
| IS 2026 (Part 1):2011 / IEC 60076-1 | Power transformers | Impedance voltage, ratings, Dyn11 vector group |
Frequently asked
How do I use the Transformer losses & payback calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the transformer losses & payback follow?
It applies IS 1180 (Part 1):2014, IEC 60076 (series), IS 2026 (Part 1):2011 / IEC 60076-1. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Regulation within the design target; Option with the lower total owning cost.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/txloss/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a transformer losses calculation?
Yes. People also call it a transformer efficiency calculator, a transformer total owning cost, a transformer regulation calculation. It covers the same calculation under electrical design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.