All calculators
Electrical · Live

Lightning protection

Risk R1 by IEC 62305-2 (collection areas, ground flash density by city, losses) to the LPS class, then the air-termination design by mesh, rolling sphere or protective angle, rods, down conductors, ring earth, separation distance and SPDs, with the roof plan DXF.

NBCS 2026 (SP 7:2026) Part D Sec 2IEC 62305-1..4:2010 / IS/IEC 62305IEC 61643-11:2011IS 3043:2018CEA (Measures relating to Safety and Electric Supply) Regulations, 2023
What goes in, what comes out

You enter

  • Building dimensions, location, occupancy, services
  • Roof plan or outline
  • LPS class override

You get

  • Risk assessment R1 with components
  • LPS design: mesh, rods, down conductors, earth
  • Roof plan DXF and report

What it does

Risk R1Collection areas for structure and lines, Ng by city, probabilities and losses; tolerable 10⁻⁵.
LPS classClass I–IV from the risk, or set by the client’s specification.
Air terminationMesh width, rolling-sphere radius or protective angle; rod count and height.
Down conductors and ringSpacing per class, natural components, ring earth and electrodes.
Separation distances = ki · kc / km · l for services near the LPS.
Roof plan DXFMesh, rods and down conductors laid on the roof outline.

Checks it performs

PASS / CHECKR1 ≤ 10⁻⁵ with the chosen LPS class
PASS / CHECKMesh width / sphere radius within the class limit
PASS / CHECKDown-conductor spacing ≤ the class limit
PASS / CHECKSeparation distance met, or bonding specified
PASS / CHECKSPD class and Iimp per line entry

Sample report

Also searched as

lightning protection risk assessment IEC 62305-2; lightning protection level calculator; rolling sphere method calculator; lightning arrester calculation for building; LPS class selection; lightning risk R1 calculation. The same calculation, the same clauses — one tool for electrical design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).

Standards applied

ReferenceTitleUsed for
NBCS 2026 (SP 7:2026) Part D Sec 2National Building Construction Standards — Electrical and allied installationsLoad assessment and diversity, circuits, cables (4-core), earthing, lightning protection, standby supply for fire & life-safety loads
IEC 62305-1..4:2010 / IS/IEC 62305Protection against lightningSPD type 1/2 selection, risk assessment (future)
IEC 61643-11:2011Surge protective devices connected to low-voltage power systemsSPD ratings (Iimp, In, Up)
IS 3043:2018Code of practice for earthingEarth bus, strip sizing, earthing of panels (future earthing tool)
CEA (Measures relating to Safety and Electric Supply) Regulations, 2023Central Electricity Authority safety regulationsStatutory safety requirements for installations

Frequently asked

How do I use the Lightning protection calculator?

Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.

Which codes and standards does the lightning protection follow?

It applies NBCS 2026 (SP 7:2026) Part D Sec 2, IEC 62305-1..4:2010 / IS/IEC 62305, IEC 61643-11:2011, IS 3043:2018, CEA (Measures relating to Safety and Electric Supply) Regulations, 2023. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.

What does it check?

Every run is marked PASS or CHECK against: R1 ≤ 10⁻⁵ with the chosen LPS class; Mesh width / sphere radius within the class limit; Down-conductor spacing ≤ the class limit; Separation distance met, or bonding specified; SPD class and Iimp per line entry.

Is the calculator free to use?

Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.

Can I see a sample report before I use it?

Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/lightning/ — inputs, results with basis, checks, worked example, drawing and the standards list.

Is this the same as a lightning protection risk assessment IEC 62305-2?

Yes. People also call it a lightning protection level calculator, a rolling sphere method calculator, a lightning arrester calculation for building. It covers the same calculation under electrical design, with the Indian and international code regimes selectable.

Does it work with AutoCAD or ZWCAD?

Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.