Neutral earthing resistor
Neutral earthing resistor for a resistance-earthed system: ohms for the earth-fault current limit, energy and power for the time rating, the charging-current check for high-resistance earthing, and the short-time kVA of a zig-zag earthing transformer.
You enter
- System voltage
- Fault current limit, time rating
- Charging current, neutral source
You get
- NER ohms, energy, power
- Earthing transformer kVA
- Report
What it does
Checks it performs
Sample report
Inputs, results with basis, checks, worked example, drawing and the standards list. Read it before you pay.
Also searched as
neutral earthing resistor sizing; NER calculation; earthing transformer sizing zig zag. The same calculation, the same clauses — one tool for electrical design under the Indian codes (NBC, IS, CPWD) or the international ones (IEC, NFPA, ASHRAE, EN).
Standards applied
| Reference | Title | Used for |
|---|---|---|
| IEEE Std 142-2007 (Green Book) | Recommended practice for grounding of industrial and commercial power systems | Resistance earthing of the system neutral |
| IEEE Std 32 | Requirements, terminology and test procedures for neutral grounding devices | Neutral earthing resistor time ratings and temperature rise |
| IEC 60909-0:2016 | Short-circuit currents in three-phase a.c. systems — Calculation of currents | Impedance method, voltage factor c (1.05 / 1.10 max, 0.95 min), peak factor κ = 1.02 + 0.98·e^(−3R/X), Ik" = c·Un/(√3·Zk) |
Frequently asked
How do I use the Neutral earthing resistor calculator?
Open the tool, change the pre-filled example to your project, read the results, checks and worked steps as you type, then export the report, Excel and DXF.
Which codes and standards does the neutral earthing resistor follow?
It applies IEEE Std 142-2007 (Green Book), IEEE Std 32, IEC 60909-0:2016. Every result line shows the formula and the clause it comes from, and the report lists the standards applied.
What does it check?
Every run is marked PASS or CHECK against: Resistor current ≥ system charging current; Earth-fault relays pick up well below the limit.
Is the calculator free to use?
Yes — running the calculation, reading the results, checks and clauses is free. One design credit unlocks the report, Excel and DXF exports for 30 days; the first design is free on sign-in.
Can I see a sample report before I use it?
Yes, a complete sample report for this tool is published at https://calc.designlink.in/samples/ner/ — inputs, results with basis, checks, worked example, drawing and the standards list.
Is this the same as a neutral earthing resistor sizing?
Yes. People also call it a NER calculation, a earthing transformer sizing zig zag. It covers the same calculation under electrical design, with the Indian and international code regimes selectable.
Does it work with AutoCAD or ZWCAD?
Yes — with the free DesignLink CAD plugin the tool reads rooms, layers and selections from the open drawing and places its DXF output straight back into the plan; without the plugin you upload a DXF and download the result.